ABB S203-C1

S203-C1 Miniature Circuit Breaker - 3P - C - 1 A

(5 offers)
Image of the product S203-C1
A total of  3 Part In-Stock from 3 Distributors
Used: 3 pcs.
System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200 to save 50% space.

Suppliers

In-Stock Parts

These parts are ready to be shipped immediately from warehouses across the world. Send inquiry for supplier details.
Register to See Company
Country: United Kingdom
In Stock Updated 28/03/2024
  • Quantity: Used: 1 pcs.
Register to See Company
Country: Switzerland
In Stock Updated 28/03/2024
  • Quantity: Used: 1 pcs.
Register to See Company
Country: United Kingdom
In Stock Updated 28/03/2024
  • Quantity: Used: 1 pcs.

On Request Parts

These parts are not in the warehouse and will be quoted with manufacturer lead time. Send inquiry for supplier details.
Register to See Company
Country: United States
On Request Updated 28/03/2024
  • Quantity: New Surplus: 0 pcs. Used: 0 pcs.

Additional information

Part Number S203-C1
UPC 40167795234240
UNSPSC 39121603
ETIM Group code: EG000020
Group description: Circuit breakers and fuses
Class code: EC000042
Class description: Miniature circuit breaker (MCB)
Version: 7

Installation

Instructions and Manuals 2CDS207104P0002

Dimensions

Width in Number of Modular Spacings 3
Product Net Width 52.5 mm
Product Net Height 88 mm
Product Net Depth / Length 69 mm
Product Net Weight 0.375 kg
Pole Net Weight 0.125 kg
Built-In Depth (t2) 69 mm
Dimension Diagram 2CDC022007F0010

ABB EcoSolutions

ABB EcoSolutions Yes

Technical

Standards IEC/EN 60898-1IEC/EN 60947-2UL 1077
Tripping Characteristic C
Rated Operational Voltage acc. to IEC 60898-1 400 V ACacc. to IEC 60947-2 440 V AC
Operational Voltage Maximum (Incl. Tolerance) 440 V ACMinimum 12 V ACMinimum 12 V DC
Rated Insulation Voltage (Ui) acc. to IEC/EN 60664-1 440 V
Rated Impulse Withstand Voltage (Uimp) 4 kVat 2000 m 5 kVat Sea Level 6.2 kV
Dielectric Test Voltage 50/60 Hz, 1 min: 2 kV
Input Voltage Type AC/DC
Rated Current (In) 1 A
Rated Short-Circuit Capacity (AC) 6 kA(DC) 6 kA(400 V AC) 6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu) (230 V AC) 20 kA(400 V AC) 10 kA(440 V AC) 10 kA
Rated Conditional Short-Circuit Current (Inc) (230 V) 20 kA(400 V) 20 kA
Rated Service Short-Circuit Breaking Capacity (Ics) (230 V AC) 15 kA(400 V AC) 7.5 kA(440 V AC) 7.5 kA
Frequency (f) 50 Hz
Rated Frequency (f) 50 / 60 Hz
Power Loss 4.2 Wat Rated Operating Conditions per Pole 1.4 W
Power Supply Connection Arbitrary
Contact Position Indication Red ON / Green OFF
Energy Limiting Class 3
Electrical Endurance 20000 AC cycle
Mechanical Endurance 20000 cycle
Number of Poles 3
Number of Protected Poles 3
Overvoltage Category III
Tightening Torque 2.8 N·m
Mounting Type DIN-Rail
Screw Terminal Type Failsafe Bi-directional Cylinder-lift Terminal
Actuator Marking I / O
Actuator Material Insulation Group II, Black, Sealable
Housing Material Insulation Group II, RAL 7035
Mounting on DIN Rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting Position any
Recommended Screw Driver Pozidriv 2
Accessories Available Yes
Connecting Capacity Busbar 10 / 10 mm²Flexible with Ferrule 0.75 ... 25 mm²Flexible 0.75 ... 25 mm²Rigid 0.75 ... 35 mm²Stranded 0.75 ... 35 mm²
Installation Size acc. to DIN 43880 1
Wire Stripping Length 12.5 mm
Terminal Type Screw Terminals

Eco Transparency

Environmental Product Declaration - EPD 9AKK108467A7832

Classifications

ETIM 9 EC000042 - Miniature circuit breaker (MCB)
EPLAN Function Definition Circuit breaker / Triple circuit breaker / Triple circuit breaker 1_2_3_4_5_6
WEEE Category 5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B Business To Business
CN8 8536 20 10
EClass V11.0 : 27141901
IDEA Granular Category Code (IGCC) 4897 >> Miniature circuit breakers
Object Classification Code F

Environmental

Ambient Air Temperature Operation -25 ... +55 °CStorage -40 ... +70 °C
Reference Ambient Air Temperature 30 °C
Degree of Protection IP20Enclosure with Cover IP40
Pollution Degree 3
Environmental Conditions 28 cycleswith 55 °C / 90-96 %and 25 °C / 95-100 %
Resistance to Vibrations acc. to IEC 60068-2-6 5g, 20 cycles at 5 ... 150 ... 5 Hz with load 0.8 In
Resistance to Shock acc. to IEC 60068-2-27 25g 2 shocks 13 ms
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Information 2CDK403001D0607
REACH Declaration 9AKK107492A1906

Circular Value

Circular Design Principles Recyclability Rate Design for Closing Resource Loops - Standard EN45555 - 90 %
Sustainable Material Content 0 %
Offered with Extended Lifetime Product Durability
Offered with Takeback Services Take Back for Recycling

Technical UL/CSA

Maximum Operating Voltage UL/CSA 110 V DC480Y/277 V AC
Interrupting Rating acc. to UL1077 (277 V AC) 6 kA(480Y / 277 V AC) 6 kA(240 V) 10 kA
Connecting Capacity UL/CSA Busbar 18-8 AWGConductor 18-4 AWG
Tightening Torque UL/CSA 18 in·lb

Ordering

Minimum Order Quantity 1 piece
Package Level 1 Units carton 1 piece
Package Level 1 Gross Weight 0.4 kg
E-Number (Finland) 3211017
E-Number (Sweden) 2100582