ABB S203-C1
S203-C1 Miniature Circuit Breaker - 3P - C - 1 A
(5 offers)Never miss out on the parts you need!
Register now to receive instant notifications soon as they become available.
Register NowBenefits of creating an account.
- Register for instant notifications on part availability
- Get real-time alerts on inventory changes
- Notifications about hte total available quantity and conditions for each product.
A total of 3 Part In-Stock from 3 Distributors
Used: 3 pcs.
System pro M compact S200 miniature circuit breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in different characteristics (B,C,D,K,Z), configurations (1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 6 kA at 230/400 V AC) and rated currents (up to 63A). All MCBs of the product range S200 comply with IEC/EN 60898-1, IEC/EN 60947-2, UL1077 allowing the use for residential, commercial and industrial applications. Bottom-fitting auxiliary contact can be mounted on S200 to save 50% space.
Suppliers
In-Stock Parts
These parts are ready to be shipped immediately from warehouses across the world. Send inquiry for supplier details.
On Request Parts
These parts are not in the warehouse and will be quoted with manufacturer lead time. Send inquiry for supplier details.
Register to See Company
Country:
United States
On Request
Updated 28/03/2024
- Quantity: New Surplus: 0 pcs. Used: 0 pcs.
Additional information
Part Number | S203-C1 |
---|---|
UPC | 40167795234240 |
UNSPSC | 39121603 |
ETIM | Group code: EG000020 Group description: Circuit breakers and fuses Class code: EC000042 Class description: Miniature circuit breaker (MCB) Version: 7 |
Installation
Instructions and Manuals | 2CDS207104P0002 |
---|
Dimensions
Width in Number of Modular Spacings | 3 |
---|---|
Product Net Width | 52.5 mm |
Product Net Height | 88 mm |
Product Net Depth / Length | 69 mm |
Product Net Weight | 0.375 kg |
Pole Net Weight | 0.125 kg |
Built-In Depth (t2) | 69 mm |
Dimension Diagram | 2CDC022007F0010 |
ABB EcoSolutions
ABB EcoSolutions | Yes |
---|
Technical
Standards | IEC/EN 60898-1IEC/EN 60947-2UL 1077 |
---|---|
Tripping Characteristic | C |
Rated Operational Voltage | acc. to IEC 60898-1 400 V ACacc. to IEC 60947-2 440 V AC |
Operational Voltage | Maximum (Incl. Tolerance) 440 V ACMinimum 12 V ACMinimum 12 V DC |
Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 440 V |
Rated Impulse Withstand Voltage (Uimp) | 4 kVat 2000 m 5 kVat Sea Level 6.2 kV |
Dielectric Test Voltage | 50/60 Hz, 1 min: 2 kV |
Input Voltage Type | AC/DC |
Rated Current (In) | 1 A |
Rated Short-Circuit Capacity | (AC) 6 kA(DC) 6 kA(400 V AC) 6 kA |
Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (230 V AC) 20 kA(400 V AC) 10 kA(440 V AC) 10 kA |
Rated Conditional Short-Circuit Current (Inc) | (230 V) 20 kA(400 V) 20 kA |
Rated Service Short-Circuit Breaking Capacity (Ics) | (230 V AC) 15 kA(400 V AC) 7.5 kA(440 V AC) 7.5 kA |
Frequency (f) | 50 Hz |
Rated Frequency (f) | 50 / 60 Hz |
Power Loss | 4.2 Wat Rated Operating Conditions per Pole 1.4 W |
Power Supply Connection | Arbitrary |
Contact Position Indication | Red ON / Green OFF |
Energy Limiting Class | 3 |
Electrical Endurance | 20000 AC cycle |
Mechanical Endurance | 20000 cycle |
Number of Poles | 3 |
Number of Protected Poles | 3 |
Overvoltage Category | III |
Tightening Torque | 2.8 N·m |
Mounting Type | DIN-Rail |
Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal |
Actuator Marking | I / O |
Actuator Material | Insulation Group II, Black, Sealable |
Housing Material | Insulation Group II, RAL 7035 |
Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
Mounting Position | any |
Recommended Screw Driver | Pozidriv 2 |
Accessories Available | Yes |
Connecting Capacity | Busbar 10 / 10 mm²Flexible with Ferrule 0.75 ... 25 mm²Flexible 0.75 ... 25 mm²Rigid 0.75 ... 35 mm²Stranded 0.75 ... 35 mm² |
Installation Size | acc. to DIN 43880 1 |
Wire Stripping Length | 12.5 mm |
Terminal Type | Screw Terminals |
Eco Transparency
Environmental Product Declaration - EPD | 9AKK108467A7832 |
---|
Classifications
ETIM 9 | EC000042 - Miniature circuit breaker (MCB) |
---|---|
EPLAN Function Definition | Circuit breaker / Triple circuit breaker / Triple circuit breaker 1_2_3_4_5_6 |
WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
WEEE B2C / B2B | Business To Business |
CN8 | 8536 20 10 |
EClass | V11.0 : 27141901 |
IDEA Granular Category Code (IGCC) | 4897 >> Miniature circuit breakers |
Object Classification Code | F |
Environmental
Ambient Air Temperature | Operation -25 ... +55 °CStorage -40 ... +70 °C |
---|---|
Reference Ambient Air Temperature | 30 °C |
Degree of Protection | IP20Enclosure with Cover IP40 |
Pollution Degree | 3 |
Environmental Conditions | 28 cycleswith 55 °C / 90-96 %and 25 °C / 95-100 % |
Resistance to Vibrations acc. to IEC 60068-2-6 | 5g, 20 cycles at 5 ... 150 ... 5 Hz with load 0.8 In |
Resistance to Shock acc. to IEC 60068-2-27 | 25g 2 shocks 13 ms |
RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
RoHS Information | 2CDK403001D0607 |
REACH Declaration | 9AKK107492A1906 |
Circular Value
Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 90 % |
---|---|
Sustainable Material Content | 0 % |
Offered with Extended Lifetime | Product Durability |
Offered with Takeback Services | Take Back for Recycling |
Technical UL/CSA
Maximum Operating Voltage UL/CSA | 110 V DC480Y/277 V AC |
---|---|
Interrupting Rating acc. to UL1077 | (277 V AC) 6 kA(480Y / 277 V AC) 6 kA(240 V) 10 kA |
Connecting Capacity UL/CSA | Busbar 18-8 AWGConductor 18-4 AWG |
Tightening Torque UL/CSA | 18 in·lb |
Ordering
Minimum Order Quantity | 1 piece |
---|---|
Package Level 1 Units | carton 1 piece |
Package Level 1 Gross Weight | 0.4 kg |
E-Number (Finland) | 3211017 |
E-Number (Sweden) | 2100582 |