BSH0553P01F2A
- Neu1 Stk.
Kategorien
Zurück zu:Alle KategorienFilter
SIRIUS motor starter M200D Technology module Reversing starter Electronic switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A, Electronic overload protection Thermistor:, THERMOCLICK / PTC with brake contact, 400 V AC 4 DI / 2 DO Han Q4/2 - Han Q8/0 via communication module 3RK1305* can be used on PROFIBUS or PROFINET
SIRIUS motor starter M200D Technology module Reversing starter Electronic switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A, Electronic overload protection Thermistor:, THERMOCLICK / PTC with brake contact, 400 V AC 4 DI / 2 DO Han Q4/2 - Han Q8/0 via communication module 3RK1305* can be used on PROFIBUS or PROFINET
SIRIUS motor starter M200D AS-i, Communication: AS-Interface reversing starter Basic Electronic, switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A, Electronic overload protection Thermistor:, THERMOCLICK / PTC with brake contact, 400 V AC 2DI AS-i + 2DI / 1DO, on device Han Q4/2 - Han Q8/0 with manual, on-site operation and key-operated switch
SIRIUS motor starter M200D AS-i, Communication: AS-Interface reversing starter Basic Electronic, switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A, Electronic overload protection Thermistor:, THERMOCLICK / PTC with brake contact, 400 V AC 2DI AS-i + 2DI / 1DO, on device Han Q4/2 - Han Q8/0 with manual, on-site operation and key-operated switch
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e and push-in connection
Hybrid motor starter for reversing 3~ AC motors up to 500 V AC and 0.6 A output current, with 24 V DC control voltage, adjustable overload shutdown and emergency stop function to SIL 3/PL e and push-in connection
This product is part of the Lexium 52 & Motors range, an offer of servo motors for PacDrive 3. The 4-pole servo motor features maximum mechanical speed of 6000RPM and parallel key shaft end with holding brake. It is an equipped with an absolute single-turn SinCos Hiperface® encoder with 128 periods speed feedback resolution. It is a servo motor with a rated supply voltage of 115V to 480V, a continuous stall current of 6.6A and a continuous power of 2400W. The shaft dimensions are 19mm (diameter) x 40mm (length). It is furnished with rotatable right angled connectors for electrical connection. It is an IP54 and IP65 rated product. The length of this product is 271.5mm and the centering collar dimensions are 3.5mm (depth) x 95mm (diameter) with 115mm mounting hole. It weighs 8kg. This range is compatible with PacDrive 3 for motion centric machines. It supports 100mm international standard flange mount with a natural convection cooling system. Lexium 52 provides an ideal counterbalance to the Lexium 62 multi-axis servo system, making the PacDrive system one of the most flexible motion control solutions. Lexium Stand alone servo drives from 0.4kW and 7kW for PacDrive based automation solutions.
This product is part of the Lexium 52 & Motors range, an offer of servo motors for PacDrive 3. The 4-pole servo motor features maximum mechanical speed of 6000RPM and parallel key shaft end with holding brake. It is an equipped with an absolute single-turn SinCos Hiperface® encoder with 128 periods speed feedback resolution. It is a servo motor with a rated supply voltage of 115V to 480V, a continuous stall current of 6.6A and a continuous power of 2400W. The shaft dimensions are 19mm (diameter) x 40mm (length). It is furnished with rotatable right angled connectors for electrical connection. It is an IP54 and IP65 rated product. The length of this product is 271.5mm and the centering collar dimensions are 3.5mm (depth) x 95mm (diameter) with 115mm mounting hole. It weighs 8kg. This range is compatible with PacDrive 3 for motion centric machines. It supports 100mm international standard flange mount with a natural convection cooling system. Lexium 52 provides an ideal counterbalance to the Lexium 62 multi-axis servo system, making the PacDrive system one of the most flexible motion control solutions. Lexium Stand alone servo drives from 0.4kW and 7kW for PacDrive based automation solutions.
SIRIUS motor starter M200D Technology module Reversing starter Electronic switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC with brake contact 400 V AC 4 DI / 2 DO Han Q4/2 - Han Q8/0 with manual on-site operation and key-operated switch via communication module 3RK1305* can be used on PROFIBUS or PROFINET
SIRIUS motor starter M200D Technology module Reversing starter Electronic switching AC-3, 0.75KW / 400 V 0.15 A...2.00 A Electronic overload protection Thermistor: THERMOCLICK / PTC with brake contact 400 V AC 4 DI / 2 DO Han Q4/2 - Han Q8/0 with manual on-site operation and key-operated switch via communication module 3RK1305* can be used on PROFIBUS or PROFINET
SIRIUS soft starter 200-480 V 315 A. 24 V AC/DC Screw terminals Thermistor input
SIRIUS soft starter 200-480 V 315 A. 24 V AC/DC Screw terminals Thermistor input
TeSys U control and diagnostic unit to be inserted in advanced power bases LUB120, LUB320, LUB380 to form a TeSys U starter controller, for 1-phase motor applications up to 2.2kW@400V. It provides full protection to motors with a rated current Ir 3-12A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). For diagnostics, it provides a thermal overload alarm to be managed with an additional function module (to be ordered separately) and a test push button for overload simulation. To be used with a 24V AC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
TeSys U control and diagnostic unit to be inserted in advanced power bases LUB120, LUB320, LUB380 to form a TeSys U starter controller, for 1-phase motor applications up to 2.2kW@400V. It provides full protection to motors with a rated current Ir 3-12A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). For diagnostics, it provides a thermal overload alarm to be managed with an additional function module (to be ordered separately) and a test push button for overload simulation. To be used with a 24V AC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).