Additional Information
- Part Number
- 1SAM360000R1015
- UNSPSC
- 39121521
- ETIM
- Group Code : EG000017
- Group Description : Low-voltage Industrial Components
- Class Description : Motor protection circuit-breaker
- Class Code : EC000074
- Version : 7
Dimensions
- Product Net Width
- 45 mm
- Product Net Height
- 97.8 mm
- Product Net Depth / Length
- 86.55 mm
- Product Net Weight
- 0.31 kg
Technical
- Rated Service Short-Circuit Breaking Capacity (Ics)
- (230 V AC) 30 kA(400 V AC) 30 kA(440 V AC) 30 kA(500 V AC) 10 kA(690 V AC) 3 kA
- Rated Ultimate Short-Circuit Breaking Capacity (Icu)
- (230 V AC) 50 kA(400 V AC) 50 kA(440 V AC) 30 kA(500 V AC) 10 kA(690 V AC) 3 kA
- Rated Instantaneous Short-Circuit Current Setting (Ii)
- 400 A
- Setting Range
- None
- Rated Operational Power AC-3 (Pe)
- (400 V) Three Phase 15 kW
- Rated Operational Power AC-3e (Pe)
- (400 V) Three Phase 15 kW
- Rated Operational Voltage
- Main Circuit 690 V AC
- Rated Operational Current (Ie)
- 32 A
- Rated Operational Current AC-3 (Ie)
- 32 A
- Rated Operational Current AC-3e (Ie)
- 32 A
- Rated Frequency (f)
- Main Circuit 50 HzMain Circuit 60 Hz
- Rated Impulse Withstand Voltage (Uimp)
- Main Circuit 6 kV
- Rated Insulation Voltage (Ui)
- 690 V
- Power Loss
- at Rated Operating Conditions per Pole 3.1 W
- Number of Poles
- 3
- Conventional Free-air Thermal Current (Ith)
- Main Circuit 32 A
- Degree of Protection
- Housing IP20Main Circuit Terminals IP10
- Pollution Degree
- 3
- Electrical Durability
- 50000 cycle
- Mechanical Durability
- 100000 cycle
- Terminal Type
- Screw Terminals
- Connecting Capacity Main Circuit
- Flexible with Ferrule 1/2x 0.75 ... 6 mm²Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²Flexible 1/2x 1 ... 2.5 mm²Flexible 1/2x 2.5 ... 6 mm²Rigid 1/2x 1 ... 2.5 mm²Rigid 1/2x 2.5 ... 6 mm²
- Tightening Torque
- Main Circuit 2 N·m
- Wire Stripping Length
- Main Circuit 10 mm
- Recommended Screw Driver
- Pozidriv 2
- Mounting Position
- 1 ... 6
- Mounting on DIN Rail
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- Minimum Mounting Distance
- Electrical Conductive Board, Horizontal - Up to 400 V 0 mmElectrical Conductive Board, Horizontal - Up to 690 V 1.5 mmElectrical Conductive Board, Vertical 75 mmOther Device Same Type, Horizontal 0 mmOther Device Same Type, Vertical 150 mm
- Actuator Type
- Rotary Handle
- Contact Position Indication
- ON / OFF / TRIP
- Standards
- IEC/EN 60947-1IEC/EN 60947-2IEC/EN 60947-4-1UL 60947-1UL 60947-4-1
- Remarks
- For overload protection of the motors, an appropriate thermal or electronic overload relays must be used
Classifications
- Object Classification Code
- F
- ETIM 4
- EC000074 - Motor protective circuit-breaker
- ETIM 5
- EC000074 - Motor protective circuit-breaker
- EClass
- V11.0 : 27370401
- IDEA Granular Category Code (IGCC)
- 4731 >> Manual Starters
- E-Number (Finland)
- 3705893
- E-Number (Sweden)
- 3110043
Environmental
- Ambient Air Temperature
- Around the Enclosure 0 ... +40 °COperation -25 ... +60 °CStorage -50 ... +80 °C
- Ambient Air Temperature Compensation
- No
- Maximum Operating Altitude Permissible
- 2000 m
- Resistance to Shock acc. to IEC 60068-2-27
- 11 ms Pulse 25g
- Resistance to Vibrations acc. to IEC 60068-2-6
- 5g / 3 ... 150 Hz
- RoHS Status
- Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Technical UL/CSA
- Short-Circuit Current Rating (SCCR)
- Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kAAny UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kAAny UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
- Maximum Operating Voltage UL/CSA
- Main Circuit 600 V AC
- Horsepower Rating UL/CSA
- (200 V AC) Three Phase 7.5 Hp(208 V AC) Three Phase 10 Hp(220 ... 240 V AC) Three Phase 10 Hp(440 ... 480 V AC) Three Phase 20 Hp(550 ... 600 V AC) Three Phase 25 Hp
- Full Load Amps Motor Use
- (200 V AC) Three Phase 25.3 A(208 V AC) Three Phase 30.8 A(220 ... 240 V AC) Three Phase 28 A(440 ... 480 V AC) Three Phase 27 A(550 ... 600 V AC) Three Phase 27 A
- Locked Rotor Amps
- (200 V AC) Three Phase 146 A(208 V AC) Three Phase 179 A(220 ... 240 V AC) Three Phase 162 A(440 ... 480 V AC) Three Phase 145 A(550 ... 600 V AC) Three Phase 146 A
- General Use Rating UL/CSA
- (600 V AC) 32 A
- Connecting Capacity Main Circuit UL/CSA
- Flexible 1/2x 16-8 AWGStranded 1/2x 16-8 AWG
- Tightening Torque UL/CSA
- Main Circuit 18 in·lb
Ordering
- Minimum Order Quantity
- 1 piece
- Customs Tariff Number
- 85362010
Andere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges