ABB
B7-40-00-F-84
B7-40-00-F-84 Mini Contactor 110 ... 127 V AC - 4 NO - 0 NC - Flat-Pin Connections
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Additional Information
- Part Number
- B7-40-00-F-84
- UNSPSC
- 39121529
- ETIM
- Group Code : EG000017
- Group Description : Low-voltage Industrial Components
- Class Description : Power contactor, AC switching
- Class Code : EC000066
- Version : 7
Dimensions
- Product Net Width
- 52.5 mm
- Product Net Height
- 57.5 mm
- Product Net Depth / Length
- 46.7 mm
- Product Net Weight
- 0.17 kg
Technical
- Number of Poles
- 4
- Mini Contactor Type
- Mini Contactor
- Rated Operational Voltage
- Main Circuit 690 V ACMain Circuit 220 V DC
- Rated Frequency (f)
- Control Circuit 400 HzControl Circuit 50 HzControl Circuit 60 HzMain Circuit 60 HzMain Circuit 50 HzMain Circuit DC
- Rated Impulse Withstand Voltage (Uimp)
- Main Circuit 6 kV
- Rated Insulation Voltage (Ui)
- 690 Vacc. to UL/CSA 600 V
- Number of Main Contacts NC
- 0
- Number of Main Contacts NO
- 4
- Rated Operational Current AC-1 (Ie)
- (220 / 240 V) 40 °C 20 A(220 / 240 V) 55 °C 16 A(380 / 440 V) 40 °C 20 A(380 / 440 V) 55 °C 16 A(690 V) 40 °C 6 A(690 V) 55 °C 6 A
- Rated Operational Power AC-3 (Pe)
- (230 V) Three Phase 3 kW(400 V) Three Phase 5.5 kW(500 V) Three Phase 5.5 kW(690 V) Three Phase, NO 3 kW
- Rated Short-time Withstand Current Low Voltage (Icw)
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 96 A
- Number of Auxiliary Contacts NC
- 0
- Number of Auxiliary Contacts NO
- 0
- Conventional Free-air Thermal Current (Ith)
- Main Circuit 20 A
- Rated Control Circuit Voltage (Uc)
- 110 ... 127 V AC
- Coil Operating Limits
- (acc. to IEC 60947-4-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
- Degree of Protection
- Control Circuit Terminals IP20Main Circuit Terminals IP20
- Mechanical Durability
- 10000000 cycle
- Maximum Electrical Switching Frequency
- (AC-1) 300 cycles per hour(AC-3) 600 cycles per hour(DC-1) 600 cycles per hour(DC-3) 600 cycles per hour
- Mounting on DIN Rail
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- Power Loss
- at Rated Operating Conditions per Pole 2 Wat Rated Operating Conditions AC-1 per Pole 1.4 W
- Standards
- IEC/EN 60947-1IEC/EN 60947-4-1IEC/EN 60947-5-1UL 60947-1UL 60947-4-1
Classifications
- Object Classification Code
- Q
- ETIM 4
- EC000066 - Magnet contactor, AC-switching
- ETIM 5
- EC000066 - Magnet contactor, AC-switching
- EClass
- V11.0 : 27371003
- IDEA Granular Category Code (IGCC)
- 4761 >> Magnet contactor, AC-switching
Environmental
- Ambient Air Temperature
- Operation -25 ... +55 °CStorage -40 ... +80 °C
- Maximum Operating Altitude Permissible
- 2000 m
- Resistance to Shock acc. to IEC 60068-2-27
- 11 ms Pulse 15g
- Resistance to Vibrations acc. to IEC 60068-2-6
- 5g / 5 ... 150 Hz
- RoHS Status
- Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Technical UL/CSA
- Maximum Operating Voltage UL/CSA
- Main Circuit 600 V AC
- Full Load Amps Motor Use
- (115 V AC) Single Phase 13.8 A(200 V AC) Three Phase 7.8 A(220 ... 240 V AC) Three Phase 9.6 A(230 V AC) Single Phase 10 A(440 ... 480 V AC) Three Phase 7.6 A(550 ... 600 V AC) Three Phase 6.1 A
- Horsepower Rating UL/CSA
- (115 V AC) Single Phase 0.75 Hp(200 V AC) Three Phase 2 Hp(220 ... 240 V AC) Three Phase 3 Hp(230 V AC) Single Phase 1.5 Hp(440 ... 480 V AC) Three Phase 5 Hp(550 ... 600 V AC) Three Phase 5 Hp
- General Use Rating UL/CSA
- (600 V AC) 16 A
Ordering
- Minimum Order Quantity
- 1 piece
- Customs Tariff Number
- 85365080
Andere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges