Beschreibung
Appleton™ increased safety ATX™ JBEP Series fiberglass reinforced polyester terminal junction boxes for instrumentation applications are factory drilled and equipped. They are available in a complete range of instrumentation and control junction boxes for use in intrinsically safe or non-intrinsically safe systems. These enclosures are designed to optimize wiring space while offering a reduced footprint. They can be used in hazardous locations (Zone 0, 1 and 2, 20, 21 and 22). The JBEP Series is suitable for instrumentation and control cable, armored or un-armored cable, and shielded or non-shielded cable.- Part Number
- JBEP121209AE25
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Specifications
- Standard Materials
- Static resistant carbon filled fiberglass reinforced polyester (FRP) enclosure with stainless steel hardware. Silicone gasket for sizes 85 x 85, 120 x 120 and EPDM (ethylene propylene diene monomer rubber) gasket for other sizes
- Options
- External hinges on specific sizes, removable glands plates, nameplates, mounting pan, terminal rail, and inside pocket for document are available. See catalog pages for details.
- Custom Options
- Consult factory for custom drilling and assembly requirements
- Zones 1 and 2 Temperature Class
- T6 for Ta ≤ +40 °C (+104 °F) and T5 for Ta ≤ +60 °C (+140 °F)
- Zones 21 and 22 Surface Temperature
- T60 °C for Ta ≤ +40 °C (+104 °F), T90 °C (T194 °F) for Ta ≤ +60 °C (+140 °F)
- Zone 0 Temperature Class
- T6 for Ta ≤ +40 °C (+104 °F) and T5 for Ta ≤ +60 °C (+140 °F)
- Ambient Temperatures
- -55 °C ≤ Ta ≤ +60 °C (-67 °F ≤ Ta ≤ +140 °F)
- Ambient Temperatures: Glands
- Type 757: -60 °C to +100 °C (-40 °F to +212 °F). Type EEXe: -20 °C to +55 °C (-4 °F to +131 °F). Type E1FX, E2FX, E1FW, E2FW, T3, A2F: -60 °C to +130 °C (-76 °F to +266 °F). Type PX, PX2K: -60 °C to +100°C (-76°F to +212°F)
- Ambient Temperatures: Terminals
- Type WDU, WFF: -50 °C to +120 °C (-58 °F to +248 °F). Type SAK, AKZ: -50 °C to +100 °C (-58 °F to +212 °F)
- Ambient Temperatures: Drain/Breather
- Type DBE: -50 °C to +85 °C (-58 °F to +185 °F)
- Ambient Temperatures: Close Up Plug
- Type Bve: -40 °C to +55 °C (-40 °F to +131 °F)
Certifications and Compliances
- NEC/CEC Certifications and Compliances
- Class I, Zone 1, AEx e IIC, T5 or T6; Ex e IIC, T5 or T6; IP66
- ATEX/IECEx Certifications and Compliances
- Zone 1 and 2 - 21 and 22; Ex II 2 GD; IP66; IK10
- Other Certifications
- EURASEC and INMETRO
Andere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges