B-Line
277135
Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 11 kW, 1 N/O, 415 V 50...
- Part Number
- 277135
- EAN
- 4015082771355
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Additional Information
- Part Number
- 277135
Specifications
- Contact configuration
- 1 NO
- Terminal capacity (flexible with ferrule)
- 2 x (0.75 - 10) mm², Main cables
- Rated operational current for specified heat dissipation (In)
- 25 A
- 10.11 Short-circuit rating
- Is the panel builder's responsibility. The specifications for the switchgear must be observed.
- Rated operational power at AC-3, 380/400 V, 50 Hz
- 11 kW
- Conventional thermal current ith (3-pole, enclosed)
- 36 A
- Rated operational power at AC-4, 380/400 V, 50 Hz
- 6 kW
- Rated operational current (Ie) at AC-4, 440 V
- 13 A
- Rated control supply voltage (Us) at AC, 50 Hz - min
- 415 V
- 10.4 Clearances and creepage distances
- Meets the product standard's requirements.
- Number of contacts (normally closed) as main contact
- 0
- Conventional thermal current ith at 55°C (3-pole, open)
- 42 A
- Rated operational power (NEMA)
- 11 kW
- 10.2.3.1 Verification of thermal stability of enclosures
- Meets the product standard's requirements.
- Ambient storage temperature - min
- 40 °C
- Rated breaking capacity at 380/400 V
- 250 A
- Rated control supply voltage (Us) at AC, 50 Hz - max
- 415 V
- Rated breaking capacity at 660/690 V
- 150 A
- Rated operational current (Ie) at DC-1, 220 V
- 40 A
- Ambient operating temperature - max
- 60 °C
- Rated operational power at AC-4, 440 V, 50 Hz
- 7 kW
- Electrical connection type of main circuit
- Screw connection
- Number Of Poles
- Three-pole
- Ambient operating temperature - min
- -25 °C
- 10.6 Incorporation of switching devices and components
- Does not apply, since the entire switchgear needs to be evaluated.
- 10.2.6 Mechanical impact
- Does not apply, since the entire switchgear needs to be evaluated.
- 10.3 Degree of protection of assemblies
- Does not apply, since the entire switchgear needs to be evaluated.
- Application
- Contactors for Motors
- Operating frequency
- 5000 mechanical Operations/h (AC operated)
- Voltage type
- AC
- Short-circuit protection rating (type 1 coordination) at 400 V
- 100 A gG/gL
- Product category
- Contactors
- Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V
- 13 A
- Power consumption, pick-up, 50 Hz
- 52 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
- Heat dissipation capacity Pdiss
- 0 W
- Switching time (AC operated, make contacts, opening delay) - min
- 8 ms
- Continuous ampere rating
- 170 A
- Rated operational current (Ie) at AC-4, 500 V
- 13 A
- Rated operational power at AC-3, 240 V, 50 Hz
- 8.5 kW
- Terminal capacity (solid/stranded AWG)
- Single 18 - 6, double 18 - 8, Main cables
- 10.9.2 Power-frequency electric strength
- Is the panel builder's responsibility.
- Degree of protection
- IP00
- Overvoltage category
- III
- Switching time (AC operated, make contacts, opening delay) - max
- 14 ms
- Ambient storage temperature - max
- 80 °C
- Pollution degree
- 3
- Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
- 45 A
- Power consumption, pick-up, 60 Hz
- 67 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
- Switching time (AC operated, make contacts, closing delay) - max
- 22 ms
- Rated impulse withstand voltage (Uimp)
- 8000 V AC
- Connection
- Screw connection
- Tightening torque
- 1.2 Nm, Screw terminals, Control circuit cables
- Rated operational power at AC-4, 660/690 V, 50 Hz
- 8.5 kW
- Conventional thermal current ith (1-pole, enclosed)
- 90 A
- Rated operational current (Ie) at AC-3, 660 V, 690 V
- 15 A
- Type
- Full voltage non-reversing small contactor
- 10.2.2 Corrosion resistance
- Meets the product standard's requirements.
- 10.2.4 Resistance to ultra-violet (UV) radiation
- Meets the product standard's requirements.
- 10.2.7 Inscriptions
- Meets the product standard's requirements.
- Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
- 25 A
- Number of contacts (normally open contacts)
- 1
- Switching time (AC operated, make contacts, closing delay) - min
- 16 ms
- Short-circuit protection rating (type 2 coordination) at 400 V
- 35 A gG/gL
- Number of auxiliary contacts (normally open contacts)
- 1
- Shock resistance
- 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
- Rated operational current (Ie) at DC-1, 110 V
- 40 A
- Drop-out voltage
- AC operated: 0.6 - 0.3 x UC, AC operated
- Power consumption, sealing, 60 Hz
- 2.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
- Resistance per pole
- 2.7 mΩ
- Ambient operating temperature (enclosed) - min
- 25 °C
- Stripping length (control circuit cable)
- 10 mm
- 10.12 Electromagnetic compatibility
- Is the panel builder's responsibility. The specifications for the switchgear must be observed.
- Amperage Rating
- 170A
- 10.2.5 Lifting
- Does not apply, since the entire switchgear needs to be evaluated.
- Stripping length (main cable)
- 10 mm
- Ambient operating temperature (enclosed) - max
- 40 °C
- Rated control supply voltage (Us) at DC - min
- 0 V
- Frequency rating
- 50-60 Hz
- 10.8 Connections for external conductors
- Is the panel builder's responsibility.
- Number of main contacts (normally open contact)
- 3
- Rated breaking capacity at 220/230 V
- 250 A
- Screw size
- M5, Terminal screw, Main cables
- Rated operational current (Ie) at AC-4, 400 V
- 13 A
- Terminals
- Screw terminals
- Short-circuit protection rating (type 2 coordination) at 690 V
- 35 A gG/gL
- Protection
- Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
- Power consumption, sealing, 50 Hz
- 7.1 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
- Terminal capacity (stranded)
- 1 x 16 mm², Main cables
- Rated breaking capacity at 500 V
- 250 A
- Rated operational power at AC-3, 415 V, 50 Hz
- 14.5 kW
- Climatic proofing
- Damp heat, constant, to IEC 60068-2-78
- Emitted interference
- According to EN 60947-1
- Connection to SmartWire-DT
- No
- Static heat dissipation, non-current-dependent Pvs
- 2.1 W
- Rated control supply voltage (Us) at DC - max
- 0 V
- 10.9.3 Impulse withstand voltage
- Is the panel builder's responsibility.
- Utilization category
- AC-4: Normal AC induction motors: starting, plugging, reversing, inching
- Coil voltage
- 415-480 Vac, 50/60 Hz
- Rated operational current (Ie) at AC-3, 440 V
- 25 A
- 10.5 Protection against electric shock
- Does not apply, since the entire switchgear needs to be evaluated.
- Safe isolation
- 440 V AC, Between coil and contactss, According to EN 61140
- Used with
- Can be combined with auxiliary contacts: DILM32-XHI, DILA-XHI(V)
- 10.13 Mechanical function
- The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
- 10.9.4 Testing of enclosures made of insulating material
- Is the panel builder's responsibility.
- Heat dissipation per pole, current-dependent Pvid
- 1.4 W
- Operating temperature - min
- -40 °C
- Rated operational current (Ie) at AC-4, 660 V, 690 V
- 10 A
- Equipment heat dissipation, current-dependent Pvid
- 4.2 W
- Pick-up voltage
- 0.8 - 1.1 V AC x Uc
- Suitable for
- Also motors with efficiency class IE3
- Operation
- Reversing
- Terminal capacity (solid)
- 2 x (0.75 - 10) mm², Main cables
- Number of auxiliary contacts (normally closed contacts)
- 0
- Interference immunity
- According to EN 60947-1
- Power consumption
- 11 kW
- 10.2.3.2 Verification of resistance of insulating materials to normal heat
- Meets the product standard's requirements.
- Operating temperature - max
- 60 °C
- 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
- Meets the product standard's requirements.
- Lifespan, mechanical
- 10,000,000 Operations (AC operated)
- Short-circuit protection rating (type 1 coordination) at 690 V
- 50 A gG/gL
- Rated making capacity up to 690 V (cos phi to IEC/EN 60947)
- 350 A
- Rated operational power at AC-4, 240 V, 50 Hz
- 4 kW
- Rated operational power at AC-4, 500 V, 50 Hz
- 8 kW
- Voltage rating
- 400 V
- Number of contacts
- 1 NO
- Rated operational current (Ie) at DC-1, 60 V
- 40 A
- Rated operational power at AC-4, 220/230 V, 50 Hz
- 3.5 kW
- Rated operational voltage (Ue) at AC - max
- 690 V
- Rated control supply voltage (Us) at AC, 60 Hz - min
- 480 V
- 10.7 Internal electrical circuits and connections
- Is the panel builder's responsibility.
- 10.10 Temperature rise
- The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
- Rated operational current (Ie) at AC-3, 500 V
- 25 A
- Screwdriver size
- 2, Terminal screw, Pozidriv screwdriver
- Duty factor
- 100 %
- Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
- 25 A
- Conventional thermal current ith of main contacts (1-pole, open)
- 100 A
- Rated control supply voltage (Us) at AC, 60 Hz - max
- 480 V
- Arcing time
- 10 ms
- Rated operational power at AC-4, 415 V, 50 Hz
- 6.5 kW
- Rated insulation voltage (Ui)
- 690 V
General
- Model Code
- DILM25-10(415V50HZ,480V60HZ)
- EAN
- 4015082771355
- Product Length/Depth
- 97 mm
- Product Height
- 85 mm
- Product Width
- 45 mm
- Product Weight
- .428 kg
- Certifications
- UL
- Catalog Notes
- Contacts according to EN 50012|IE3-ready devices are identified by the logo on their packaging.
Andere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges