Additional Information
- Part Number
- CFP-Q-ADD
Loss/Length Specifications
- Testing Speeds (excludes referencing times)
- Far End Source mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection) || Smart Remote mode: < 3 seconds (2 wavelengths, one direction, auto wavelength detection) || Loopback mode: ≤ 2 seconds (2 wavelengths, one direction auto wavelength detection)
- Input/Output Connectors
- Interchangeable connector adapter (LC standard, SC, ST and FC optional)
- Launch Condition1,2
- Encircled Flux compliant to TIA-526-14-B, ISO/IEC 14763-3 and IEC 61280-4-1
- Fiber Types Tested
- 50/125 µm or 62. 5/125 µm || singlemode
- Source Type and Wavelengths
- LED source 850 nm ± 30 nm 1300 nm ± 20 nm || Fabry-Perot laser diode 1310 nm ± 20 nm 1550 nm ± 30 nm
- Maximum Length Measurement
- 12 km || 130 km
- Length Measurement Accuracy
- ± 1. 5 m plus ± 1 % of length
- Output Power (Nominal)
- ≥ -24 dBm with EF-TRC || ≥ -4 dBm
- Output Power Stability3
- ± 0. 1 dB over 8 hours ± 0. 08 dB over 15 minutes || ± 0. 05 dB over 8 hours ± 0. 03 dB over 15 minutes
Selected Specifications
- Output Power
- >-5 dBm<0 dBmSMF-28 singlemode fiberContinuous waveSC/UPC connector
- Operating Wavelength
- 650 nm nominal
- Output Modes
- Pulsed mode (2 Hz to 3 Hz blink frequency) || Continuous wave
- Connector Adapter
- 2. 5 mm universal
- Laser Safety
- Over operating temperature range || Class II CDRH
Power Meter Specifications
- Input Connector
- Interchangeable connector adapter (LC standard, SC, ST and FC optional)
- Detector Type
- InGaAs
- Wavelengths
- 850 nm, 1300 nm, 1310 nm, 1550 nm
- Power Measurement Range
- 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
- Power Measurement Uncertainty1,2
- < +/- 5% +/- 32 pW
- Measurement Linearity3
- < ± 0. 1 dB
- Re-calibration Period
- 1 year
- Integrated Wi-Fi
- Meets IEEE 802. 11 a/b/g/n; dual band (2. 4 GHz and 5 GHz)
Loss/Length Specifications (continued)
- Source Wavelengths
- 850 nm, 1300 nm, 1310 nm, 1550 nm
- Power Measurement Range
- 0 dBm to -65 dBm (850 nm) 0 dBm to -70 dBm (all other wavelengths)
- Power Measurement Uncertainty1, 2
- < +/- 5% +/- 32 pW
- Measurement Linearity3
- < ± 0. 1 dB
- Re-calibration Period
- 1 year
Environmental Specifications
- Operating Temperature
- -10° C to 45° C
- Storage Temperature
- -10° C to +60° C
- Operating Relative Humidity % RH without condensation
- % RH without condensation || 0 % to 90 %, 32 °F to 95 °F (0° C to 35° C) || 0 % to 70 %, 95 °F to 113 °F (35° C to 45° C)
- Vibration
- Random, 2 g, 5 Hz-500 Hz
- Shock
- 1 m drop test with and without module and adapters
- Safety
- CSA C22. 2 No. 1010. 1: 1992 || EN 61010-1 1st Edition + Amendments 1, 2
- Pollution Degree
- 2
- Altitude
- Operating: 4,000 m; storage: 12,000 m
- EMC
- EN 61326–1
Andere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges