Fluke
FLUKE 1621
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
1
Zahlungsmöglichkeiten:
General Specifications
- Measuring functions
- 3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage
- Intrinsic error
- Refers to the reference temperature range and is guaranteed for one year
- Measuring rate
- 2 measurements/second
- Battery1
- One 9 volt alkaline (LR61)
- Battery condition
- LO-BAT is displayed if voltage drops below 6.5 V
- Voltages Between jacks H/C2 and E/C1
- 250 Veff maximum (effective voltage)
- Voltages Between jacks S/P2 and E/C1
- 250 Veff maximum
- Climatic class
- VDE/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4/87)
- Temperature performance2
- Working: -10°C to +50°C (+14°F to +122°F)
- Temperature performance
- Operating: 0°C to +35°C (+32°F to +95°F)
- Temperature performance Storage
- -20°C to +60°C (+68°F to +140°F)
- Temperature performance Reference
- +23°C ±2°C (+73°F ±4°F)
- Temperature coefficient
- ±0.1% of range per degree Kelvin
- Safety
- IEC/EN 61010-1, 600 V CAT II, pollution degree 2
- Dimensions
- 113 x 54 x 216 mm (4.5 x 2.1 x 8.5 in), including holster
- Weight
- 850 g (1.9 lb), including standard accessories, volume approximately 600 cm3
Measuring Range
- 0.15 Ω to 20 Ω Resolution
- 0.01 Ω
- 0.15 Ω to 20 Ω Display range
- 0 to 19.99 Ω
- 200 Ω Resolution
- 0.1 Ω
- 200 Ω Display range
- 20 to 199.9 Ω
- 2 kΩ Resolution
- 1 Ω
- 2 kΩ Display range
- 200 to 1999 Ω
- Intrinsic Uncertainty
- ±(6% of measured value + 5D)
- Operating uncertainty IEC 615573
- ±(18% of measured value + 5D)
Electrical Specifications
- Maximum deviations E1 Influence factor
- Position
- Maximum deviations
- E1 Deviation influence: 0% || E2 Deviation influence: 0% || E3 Deviation influence: 2.3% || E4 Deviation influence: 0.6% || E5 Deviation influence: 10%
- Maximum deviations E2 Influence factor
- Supply voltage
- Maximum deviations E3 Influence factor
- Temperature E3
- Maximum deviations E4 Influence factor
- Serial interference voltage (20 V)
- Maximum deviations E5 Influence factor
- Probe- and auxiliary probe resistance
- Test voltage
- 3.7 kV
- Protection type
- IP 40; IEC/EN 60529
- Electromagnetic compatibility Emission
- IEC/EN 61326 Class B
- Electromagnetic compatibility
- Immunity: IEC/EN 61326 Annex C
- RE Resistance measurement
- Measuring method: Current-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC/EN 61557–5
- R Open circuit voltage
- 23 to 24 V AC
- R Short circuit current
- > 50 mA AC
- R
- Measuring frequency: 128 Hz
- R Maximum permissible overload
- 250 Veff
- Measuring time
- 8 seconds (average from when START is pressed)
- Limit input
- Tester retains set value even if instrument is turned off (assuming battery power supply is sufficient)
- Automatic changeover of resolution RH
- < 7 kΩ || < 50 kΩ || > 50 kΩ
- Automatic changeover of resolution Resolution
- 0.01 Ω || 0.1 Ω || 1 Ω
- Interference voltage display DC + AC
- Vmax: 30 Veff || Common mode rejection: > 80 dB at 50 Hz and 60 Hz || Measuring uncertainty: < 10% for pure AC and DC signals
- Interference voltage display DC + AC Ri
- 680 kΩ
Dokumente
Data Sheet
HerunterladenAndere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges