Fluke

Fluke 2686A

1 / 1
thumbnail
Part Number
Fluke 2686A
  • Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
  • Wiederverkaufsrabatte bis zu 40%!
Sign-Up
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Fordern Sie ein Angebot an und wir senden Ihnen Informationen zu Verfügbarkeit und Preis.

Technical Specifications

Channel capacity (2680A or 2686A)
20 to 120 channels per chassis (6 analog input modules of 20 channels each)One master alarm (open collector) per chassisCommunications:10BaseT/100BaseT, TCP/IP via RJ45 connector, Cat 5
Communications:
10BaseT/100BaseT, TCP/IP via RJ45 connector, Cat 5
Math functions
In addition to its analog and digital input channels, each system supports 60 computed channels. Calculations include: time & rate, addition, subtraction, multiplication, division, log, natural log, exponent, square root, absolute value, integer function and average.
Measurement speed (2680A-PAI)
Slow:6 readings/second nominalMedium:41 (50 Hz), 48 (60 Hz) readings/second nominalFast:143 readings/second for VAC nominal, 140 readings/second on 300 Ω range, 37 readings/second on 3 MΩ range)
Slow:
45 (50 Hz), 54 (60 Hz) readings/second nominal
Medium:
200 readings/second nominal
Fast:
1000 readings/second nominal (5 readings/second for VAC nominal, 370 readings/second on 300 Ω range, 44 readings/second on 3 MΩ range)
Measurement speed (2680A-FAI)
Slow:45 (50 Hz), 54 (60 Hz) readings/second nominalMedium:200 readings/second nominalFast:1000 readings/second nominal (5 readings/second for VAC nominal, 370 readings/second on 300 Ω range, 44 readings/second on 3 MΩ range)
Analog to digital converter
2680A-PAI:18 bit, multi-slope type2680A-FAI:16 bit, multi-slope type
2680A-PAI:
300 V DC or v AC rms (channels 1,11); 25% V dc or V ac rms (all other channels)
2680A-FAI:
50 V dc or 30 V ac rms (all channels)
Common mode rejection
2680A-PAI:AC: > 120 dB (50/60 Hz, + 0.1 % max 1 kΩ source imbalance) DC: > 120 dB2680A-FAI:AC: > 100 dB (50/60 Hz, + 0.1 % max 1 kΩ source imbalance) DC: > 100 dB
Normal mode rejection
50 dB @ 50/60 Hz, ± 0.1 %
Common mode voltage maximum
2680A-PAI: 300 V DC or v AC rms (channels 1,11); 25% V dc or V ac rms (all other channels)2680A-FAI:50 V dc or 30 V ac rms (all channels)
Totalizing input (2680A-DIO)
Pre-settable starting count up/down counter DC coupled, non-isolated, max + 30 V, min – 4 VMax count:4,292,967,295Minimum signal:2 V peadThreshold:1.4 VRate:0-5 kHz (debounce off)Hysteresis:500 mVInput debouncing:none or 1.66 ms
Max count:
4,292,967,295
Minimum signal:
2 V pead
Threshold:
1.4 V
Rate:
0-5 kHz (debounce off)
Hysteresis:
500 mV
Input debouncing:
none or 1.66 ms
Digital Inputs/Outputs: 20 (2680A-DIO)
Threshold:1.4 VHysteresis:500 mVMaximum input:+30V, min –4 V; non-isolated Logical “zero” output:Logical “zero” output:0.8 V max |out = -1.0 mA (1 LSTTL load equivalent) 1.8 V max |out = -20 mA 3.25 V max |out = -50 mA Output voltage depends on external load 3.8 V min |out = 0.05 mA (1 LSTTL load equivalent)
Maximum input:
+30V, min –4 V; non-isolated Logical “zero” output:
Logical “zero” output:
0.8 V max |out = -1.0 mA (1 LSTTL load equivalent)
Relays (2680A-DIO)
Quantity:8Type:form C; DPSTCurrent:1 amp, non-inductiveOperation time:75 ms
Quantity:
8
Type:
form C; DPST
Current:
1 amp, non-inductive
Operation time:
75 ms
Alarm associations (2680A-DIO)
Each Digital I/O may be randomly assigned as a digital input, status output, or alarm output (associated with any input channel or channels)
Trigger input
Minimum pulse:5 µsMinimum latency:100 msInput “High”:2.0 V min, 7.0 V maxInput “Low”:-0.6 V min, 0.8 V max non-isolated, contact closure and TTL compatible
Minimum pulse:
5 µs
Minimum latency:
100 ms
Input “High”:
2.0 V min, 7.0 V max
Input “Low”:
-0.6 V min, 0.8 V max non-isolated, contact closure and TTL compatible
Clock
Accurate to within 1 minute/month for 0 °C to 50 °C range

General Specifications

Power, battery life
100 to 240 V ac, 50 or 60 Hz 100 VA max, or 9 to 45 V dc (50 W max – all slots filled + memory card installed) (if both sources are applied simultaneously, the greater of ac or dc is used) at 120 V ac the equivalent dc voltage ~14.5 V
Temperature, humidity (non-condensing)
>Operating:-20 °C to 28 °C, 28 °C to 40 °C, 40 °C to 60 °C,Storage:-40 °C to 70 ° C, 5 % to 95 % RH
>Operating:
-20 °C to 28 °C,
Storage:
12,200 m
Altitude
Operating:2000 mStorage:12,200 m
Operating:
2000 m
Standards
All inputs:IEC Overvoltage rating Category II Product conforms to the following safety and emisions standards: EN50082-2 EN55022-1 EN550aa class A EN610000-4-2, 3, 4, 6, 8 EN61326 EN61010-1, CAT II CSA C22.2 No. 1010.1
All inputs:
IEC Overvoltage rating Category II Product conforms to the following safety and emisions standards:
Operating Temperature
–20 °C to 60 °C (–4 °F to +140 °F)
Storage Temperature
–40 °C to 70 °C (–40 °F to +158 °F)
Size
18.6” x 17 “ x 9.3” (473 mm x 423 mm x 237 mm)
Weight
2680A/2686A chassis only: 18.86 lbs (8.47 kg) 2680A-FAI: 1.74 lbs. (0.79 kg) 2680A-PAI: 2.66 lbs, (1.21 kg) 2680A-DIO: 1.75 lbs. (0.80 kg)
Interfaces
Ethernet: conforms to IEEE 802.3 Ethernet standard, compatible with 100BaseT and 10BaseT standards, uses TCP/IP protocal RS-232C: for calibration only
System Requirements
IBM compatible, Pentium II processor Microsoft Windows® NT/98/2000/XP 64 MB RAM 25% MB free hard disk space VGA or SVGA display, 100 % IBM compatible with 2 MB Video RAM (VRAM) CD-ROM drive Microsoft Internet Explorer 4.0 or later