Schneider Electric
389FXCXC1-24A
1 / 5
Beschreibung
The 389F series power relay, 389FXCXC1-24A , offers high contact rating of 20 A at 150 VAC with ability to hold motor loads up to 0.5 hp at 120 to 240 VAC with nominal coil voltage 24 VAC . Maximum switching voltage 300 V makes relay suitable for high-power switching applications. Supported ballast load contact rating perfectly suits for lighting controls. Silver alloy 3PDT contact configuration makes an ideal solution for variety of application requirements. Side flange mounting option with wide range of accessories helps increase design and installation flexibility. Environmentally friendly design is compliant with the European Restriction of Hazardous Substances directive (RoHS).- Country of Origin
- CN
- Part Number
- 389FXCXC1-24A
- EAN
- 39122324
- UNSPSC
- 39122324
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Specifications
- Contacts Type And Composition
- 3 NO + 3 NC
- Switch Function
- 3PDT
- Product Or Component Type
- power relay
Complementary
- Input Voltage
- 24 V AC
- Voltage Range
- 0.85...1.1 Uc AC
- [Ie] Rated Operational Current
- 20 A at 150 V AC (on resistive load) conforming to UL || 15 A at 250 V AC (on resistive load) conforming to UL || 13 A at 28 V DC (on resistive load) conforming to UL || 20 A at 150 V AC (ballast) conforming to UL || 6.67 A at 277 V AC (ballast) conforming to UL || 20 A at 250 V AC (NO/NC) conforming to IEC || 15 A at 28 V DC (NO/NC) conforming to IEC
- Input Resistance
- 72 Ohm
- Minimum Switching Current
- 100 mA 5 V DC
- Connections - Terminals
- Quick
- Mounting Support
- flange
- Power Consumption In W
- 1.3-1.3 W DC
- Contacts Material
- silver alloy contacts
- Power Consumption In Va
- 2-2 VA AC
- Input Current
- 20 A
- Drop-Out Voltage Threshold
- >= 0.1 Uc AC/DC
- Maximum Horse Power Rating
- 0.5 hp 120/240 V AC 50/60 Hz
- Net Weight
- 84 g
- Maximum Switching Voltage
- 300 V AC
Offer Sustainability
- China Rohs Regulation
- X
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1406038EN
- Sustainable Offer Status
- Green Premium product
- Toxic Heavy Metal Free
- Yes
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc
- Yes
Environment
- Product Certifications
- cURus || CSA || CE
- Ambient Air Temperature For Operation
- -30-55 °C
- Ambient Air Temperature For Storage
- -30-85 °C
- Electrical Durability
- 100000 cycles resistive load || 50000 cycles resistive DC load
- Mechanical Durability
- 5000000 cycles
- Dielectric Strength
- 2200 V AC between coil and contact || 2200 V AC between poles || 1600 V AC between contacts
Dokumente
Data Sheet
HerunterladenAndere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges