Schneider Electric
9038AG1
1 / 6
Beschreibung
Aktiv Reif
This product is part of the Nema Pressure Switches range, an offer of mechanical alternators. This mechanical alternator has 4 normally closed, snap action, DPST-DB (double pole single throw, double break) form YY contacts. As far as safety is concerned all dangerous machines in all sectors are involved. Preventa safety switches can be used in packaging, handling, robotics, machine tools, presses, and automotive sectors. The open tank mechanical alternator supports pedestal mounting method and vertical float rod angle for operating in any position. It is furnished with screw clamp terminals for electrical connection and 4 knockouts for 1/2inch or 3/4inch conduit. Offers electrical durability of 100 cycles and mechanical durability of 300 cycles. The enclosure is made of painted cold-rolled steel. It is suitable for pressure controlling or monitoring of water pumps, compressors, agricultural/irrigation water systems, moulding presses, injection moulders, grinding machines, machining centres, complex and special machines. It is a NEMA 1 rated product. This product is certified by CE, CSA and UL. Meets UL 508 standards. When liquid level rises to the first level, one pump turns on. Both pumps automatically turn on when a peak condition occurs and the liquid level continues to rise. If form N5 or N25 is present and the water level continues to rise. Mechanical alternator provides a simple, positive means of mechanically alternating two pumps or motors. This alternator is used on devices that are installed in a duplex system with a common tank.- Country of Origin
- MX
- Part Number
- 9038AG1
- Tariff Code
- 85365080
- EAN
- 785901591016
- UPC
- 785901591016
- UNSPSC
- 39122219
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Specifications
- Range Of Product
- Square D Pumptrol
- Product Or Component Type
- mechanical alternator
- Type Of Packing
- individual
- Product Specific Application
- mechanically alternating the operation of two pumps or motors
- Quantity Per Set
- set of 1
- Electrical Circuit Type
- power circuit
- Device Application
- open tank
- Device Short Name
- 9038A
Contractual warranty
- Warranty
- 18 months
Complementary
- Product Destination
- for open tank
- Terminal Block Type
- 8 terminals
- Terminals Description Iso N°1
- line-load-load-line
- Short-Circuit Protection
- 20 A cartridge fuse gG
- Device Mounting
- pedestal
- Force Down To Trip
- 20 ozf at minimum adjustment || 17 ozf at maximum adjustment
- Float Rod Angle
- vertical
- Factory Modification
- without
- Float Movement
- variable adjustable
- Maximum Operating Rate
- 60 cyc/mn
- Contacts Type And Composition
- 4 NC, snap action, DPST-DB, Form YY
- Float Position
- any
- Electrical Durability
- 100 cycles 60 cyc/mn
- Cable Entry Number
- 4 knock-outs for 1/2" or 3/4"conduit UL 508
- Electrical Connection
- screw-clamp terminals 10 AWG
- Contact Operation
- contacts close on liquid rise
- [Ui] Rated Insulation Voltage
- 575 V UL 508
- Controlled Fluid
- fresh water specific gravity of 0.85 in or higher || sea water specific gravity of 0.85 in or higher || hydraulic oil specific gravity of 0.85 in or higher || corrosive fluid specific gravity of 0.85 in or higher
- Force Up To Trip
- 18 ozf at minimum adjustment || 16 ozf at maximum adjustment
- Mechanical Durability
- 300 cycles
- Operating Position
- vertical position only
- Enclosure Material
- painted cold-rolled steel
- Local Signalling
- without
- Motor Power Kw
- 1.5 kW 2 hp)115 V AC, 1 phase || 2.2 kW 3 hp)115 V AC, 3 phase || 2.2 kW 3 hp)230 V AC, 1 phase || 3.7 kW 5 hp)230 V AC, 3 phase || 0.75 kW 1 hp)460 V AC, 3 phase || 0.75 kW 1 hp)475 V AC, 3 phase || 0.18 kW 0.25 hp)32 V DC || 0.37 kW 0.5 hp)115 V DC || 0.37 kW 0.5 hp)230 V DC
- Kit Composition
- rod and float are to be choosen in accessories || float switch
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP111211EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Circularity Profile
- ENVEOLI111210EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- UL listed file E12158 || CSA file LR25490
- Ambient Air Temperature For Operation
- -22-220 °F
- Standards
- CE || UL 508
- Ambient Air Temperature For Storage
- -22-220 °F
- Nema Degree Of Protection
- NEMA 1 UL 50
Andere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges