Schneider Electric
BMXAMI0410H
analog isolated high level input module, Modicon X80, 4 I, 0 to 20mA, 4 to 20mA, 10V positive or negative, severe environment
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
$490.59
1
Zahlungsmöglichkeiten:
Insgesamt 37 Parts In-Stock von 22 Distributors
Produktbedingungen:
Angebot mit Herstellervorlaufzeit
Lieferung:Auf Anfrage
Bester Preis:
€268.63
Additional Information
- Part Number
- BMXAMI0410H
- UNSPSC
- 32151705
- Tariff Code
- 8538908180
- Country of Origin
- FR
Environment
- Product Certifications
- CE || RCM || CSA || EAC || Merchant Navy || UL || ATEX || IEC-Ex
- Ambient Air Temperature For Operation
- -25-70 °C
- Standards
- EN/IEC 61010-2-201 || EN/IEC 61131-2 || UL 61010-2-201 || CSA C22.2 No 61010-2-201
- Shock Resistance
- 30 gn
- Environmental Characteristic
- gas resistant class Gx || gas resistant class 3C4 || dust resistant class 3S4 || sand resistant class 3S4 || salt resistant level 2 || mold growth resistant class 3B2 || fungal spore resistant class 3B2 || hazardous location
- Vibration Resistance
- 3 gn
- Directives
- 2014/35/EU - low voltage directive || 2014/30/EU - electromagnetic compatibility
- Ambient Air Temperature For Storage
- -40-85 °C
- Relative Humidity
- 5-95 % 55-55 °C without condensation
- Protective Treatment
- conformal coating
- Ip Degree Of Protection
- IP20
Contractual warranty
- Warranty
- 18 months
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Weee
- The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
- China Rohs Regulation
- X
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Complementary
- Mtbf Reliability
- 1200000 H
- Measurement Error
- 0.075 % of full scale +/- 10 V 25 °C || 0.075 % of full scale +/- 5 V 25 °C || 0.075 % of full scale 0...10 V 25 °C || 0.075 % of full scale 0...5 V 25 °C || 0.075 % of full scale 1...5 V 25 °C || 0.15 % of full scale +/- 20 mA 25 °C || 0.15 % of full scale 0...20 mA 25 °C || 0.15 % of full scale 4...20 mA 25 °C || <= 0.2 % of full scale +/- 10 V - 25...70 °C || <= 0.2 % of full scale +/- 5 V - 25...70 °C || <= 0.2 % of full scale 0...10 V - 25...70 °C || <= 0.2 % of full scale 0...5 V - 25...70 °C || <= 0.2 % of full scale 1...5 V - 25...70 °C || <= 0.55 % of full scale +/- 20 mA - 25...70 °C || <= 0.55 % of full scale 0...20 mA - 25...70 °C || <= 0.55 % of full scale 4...20 mA - 25...70 °C
- Maximum Conversion Value
- +/- 11.4 V +/- 10 V || +/- 11.4 V +/- 5 V || +/- 11.4 V 0...10 V || +/- 11.4 V 0...5 V || +/- 11.4 V 1...5 V || 0...30 mA +/- 20 mA || 0...30 mA 0...20 mA || 0...30 mA 4...20 mA
- Type Of Filter
- first order digital filtering
- Status Led
- 1 LED (Green) RUN || 1 LED per channel (Green) channel diagnostic || 1 LED (Red) ERR || 1 LED (Red) I/O
- Precision Of Internal Conversion Resistor
- 0.1 % - 15 ppm/°C
- Temperature Drift
- 15 ppm/°C +/- 10 V || 15 ppm/°C +/- 5 V || 15 ppm/°C 0...10 V || 15 ppm/°C 0...5 V || 15 ppm/°C 1...5 V || 30 ppm/°C +/- 20 mA || 30 ppm/°C 0...20 mA || 30 ppm/°C 4...20 mA
- Recalibration
- internal
- Common Mode Rejection
- 90 dB
- Current Consumption
- 150 mA 3.3 V DC || 45 mA 24 V DC
- Analogue Input Resolution
- 16 bits
- Minimum Crosstalk Attenuation
- 80 dB
- Net Weight
- 0.143 kg
- Input Impedance
- 10 MOhm in voltage mode || 250 Ohm + 3.6...50 Ohm internal protective resistor in current mode
- Isolation Voltage
- 300 V DC between channels || 1400 V DC between channels and ground || 1400 V DC between channels and bus
- Fast Read Cycle Time
- 1 ms + 1 ms x number of channels used
- Power Consumption In W
- 0.82 W 24 V DC typical || 1.30 W 24 V DC maximum || 0.32 W 3.3 V DC typical || 0.48 W 3.3 V DC maximum
- Digital Value Format
- 32768 to + 32767 in maximum user scale || +/- 10000 by default
- Nominal Read Cycle Time
- 5 ms for 4 channels
- Operating Altitude
- 0...6561.68 ft (0...2000 m) || 2000...5000 m with derating factor
- Analog/Digital Conversion
- 24 bits
- Measurement Resolution
- 0.35 mV +/- 10 V || 0.35 mV +/- 5 V || 0.35 mV 0...10 V || 0.35 mV 0...5 V || 0.35 mV 1...5 V || 0.92 µA +/- 20 mA || 0.92 µA 0...20 mA || 0.92 µA 4...20 mA
- Permitted Overload On Inputs
- +/- 30 V +/- 10 V || +/- 30 V +/- 5 V || +/- 30 V 0...10 V || +/- 30 V 0...5 V || +/- 30 V 1...5 V || +/- 90 mA +/- 20 mA || +/- 90 mA 0...20 mA || +/- 90 mA 4...20 mA
Specifications
- Range Of Product
- Modicon X80
- Product Or Component Type
- analog input module
- Input Level
- high level
- Electrical Connection
- 20 ways 1 connector
- Input Output Isolation
- isolated
- Analogue Input Number
- 4
- Product Specific Application
- for severe environments
- Analogue Input Type
- current +/- 20 mA || current 0...20 mA || current 4...20 mA || voltage +/- 10 V || voltage +/- 5 V || voltage 0...10 V || voltage 0...5 V || voltage 1...5 V