Relay - 600 V 10 Amp Tesys + Options
CAD32G7TQ
  • Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
  • Wiederverkaufsrabatte bis zu 40%!
Sign-Up
Preisanfrage senden
1
Zahlungsmöglichkeiten:

Additional Information

Part Number
CAD32G7TQ
UNSPSC
39121529
Country of Origin
FR

Environment

Product Certifications
CSA || UL || UKCA
Ambient Air Temperature For Operation
-40-70 °C at Uc || -5-60 °C at 0.8...1.1 Uc
Standards
EN 60947-5 || IEC 60947-5-1 || NF C 63-140 || VDE 0660 || BS 4794 || IEC 60335-1
Shock Resistance
10 gn control relay open || 15 gn control relay closed
Vibration Resistance
2 gn 5-300 Hz control relay open || 4 gn 5-300 Hz control relay closed
Ip Degree Of Protection
IP2X conforming to VDE 0106
Ambient Air Temperature For Storage
-60-80 °C
Protective Treatment
TH IEC 60068
Operating Altitude
9842.52 ft (3000 m) without derating

Contractual warranty

Warranty
18 months

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1501004
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Antimony oxide & Antimony trioxide, which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI1501004
Eu Rohs Directive
Compliant with Exemptions

Complementary

Non-Overlap Time
1.5 ms on de-energisation between NC and NO contacts || 1.5 ms on energisation between NC and NO contacts
[Ue] Rated Operational Voltage
<= 690 V AC 25...400 Hz
Height
77 mm
Control Circuit Voltage Limits
drop-out: 0.3...0.6 Uc || operational: 0.8...1.1 Uc at 50 Hz || operational: 0.85...1.1 Uc at 60 Hz
[Ith] Conventional Free Air Thermal Current
10 A (at 60 °C)
Insulation Resistance
> 10 MOhm
Irms Rated Making Capacity
140 A <= 690 V AC IEC 60947-5-1
Associated Fuse Rating
10 A gG <= 690 V IEC 60947-5-1
Net Weight
0.58 kg
Inrush Power In Va
70-70 VA (at 20 °C)
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60947
Contact Operation
mechanically linked IEC 60947-5-1
[Ui] Rated Insulation Voltage
600 VCSA || 600 VUL || 690 V III 3) IEC 60947-5-1
Maximum Operating Rate
3 cyc/s 20 °C
Minimum Switching Current
5 mA
Hold-In Power Consumption In Va
8-8 VA 50 Hz (at 20 °C)
Operating Time
12...22 ms coil energisation and NO closing || 4...12 ms coil de-energisation and NO opening || 4...19 ms coil energisation and NC opening || 6...17 ms coil de-energisation and NC closing
Width
45 mm
Depth
86 mm
Tightening Torque
1.7-1.7 N.m
Minimum Switching Voltage
17 V

Specifications

Control Circuit Type
AC
[Uc] Control Circuit Voltage
120 V AC 50/60 Hz
Contactor Application
control circuit
Product Or Component Type
auxiliary contactor
Product Name
TeSys CAD || TeSys Deca
Range
TeSys || TeSys Deca
Pole Contact Composition
3 NO + 2 NC
Connections - Terminals
1 x 1-4 mm²flexible with cable end || 1 x 1-4 mm²flexible without cable end || 1 x 1-4 mm²solid without cable end || 2 x 1-2.5 mm²flexible with cable end || 2 x 1-4 mm²flexible without cable end
Utilisation Category
AC-14 || AC-15
Quantity Per Set
set of 10
Suppressor Technology
without built-in
Device Short Name
CAD
Coil Type
standard

Dokumente

Data Sheet

Herunterladen

CAD Models

Trace parts
Trace parts
Herunterladen

Ähnliche Produkte