Schneider Electric
EX500T63H
Transformer, dry type, DOE 2016, 500kVA, 3 phase, 480V delta primary, 240V delta secondary, 30J, 150C rise
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Additional Information
- Part Number
- EX500T63H
- UNSPSC
- 39121001
Complementary
- Tap Loss
- 678.0 no load (core loss) || 6634.0 load loss (coil loss)
- Network Frequency
- 60 Hz
- Primary Voltage
- 480 V delta
- Percentage Impedance Voltage
- 0.049 %
- Height
- 1803 mm
- [Uimp] Rated Impulse Withstand Voltage
- 10 kV
- Temperature Rise
- 150 °C || 220 °C insulated
- Degree Of Protection
- UL type 1 || UL type 2, with 7400DS30J || UL type 3R, with 7400WS30J
- Number Of Tap-Offs
- 2 2.5 % FCAN || 2 2.5 % FCBN
- X/R Ratio
- 3.56
- Rated Operational Power In Va
- 500 kVA
- Electrical Connection
- 4 Hole Nema Pad primary 11.1 mm || 6 Hole Nema Pad secondary 11.1 mm
- Phase
- 3 phase
- Material
- aluminium
- Net Weight
- 1322.22 kg
- Secondary Voltage
- 240 V delta
- Percentage Reactance
- 0.0472 %
- Noise Level
- 6 dB NEMA ST-20 || 56 dB
- Type Of Cooling
- natural convection
- Efficiency
- 99.24 % at 35 % load factor , 75.0 °C
- Mounting Support
- floor || floor, with 7400FMB
- Continuous Thermal Current Rating Factor
- 2937.1940261715677 16.6 % || 3728.19165275 25 % || 7972.469783 50 % || 15046.26666675 75 % || 24949.582304 100 %
- Width
- 1226 mm
- Depth
- 963 mm
- Box Number
- 30J
- [Ipk] Rated Peak Withstand Current
- 24.5 kA
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1604028EN
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc
- Yes
- China Rohs Regulation
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Circularity Profile
- N/A
- Eu Rohs Directive
- Compliant
- Halogen Content Performance
- Halogen free plastic parts product
Environment
- Average Ambient Air Temperature For Operation
- 30 °C
- Ambient Air Temperature For Operation
- 40-40 °C
- Standards
- UL 1561 || CSA C22.2 No 47 || NEMA ST-20
Specifications
- Range Of Product
- Square D
- Product Or Component Type
- transformer
- Transformer Type
- energy efficient
- Device Application
- low voltage electrical distribution
- Device Short Name
- DOE 2016
Dokumente
Data Sheet
HerunterladenAndere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges