Schneider Electric
RE17RCMU
single function relay, Harmony Timer Relays, 8A, 1CO, 1s..100h, off delay, 24V DC or 24...240V AC DC
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
209,45 zł
1
Zahlungsmöglichkeiten:
Insgesamt 616 Parts In-Stock von 31 Distributors
Produktbedingungen:
Angebot mit Herstellervorlaufzeit
Lieferung:Auf Anfrage
Bester Preis:
€18.89
Additional Information
- Part Number
- RE17RCMU
- UNSPSC
- 39121523
- Tariff Code
- 8536490065
- Country of Origin
- ID
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP121117EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- China Rohs Regulation
- X
- Circularity Profile
- ENVEOLI121113EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Complementary
- Safety Reliability Data
- B10d = 270000 || MTTFd = 296.8 years
- Setting Accuracy Of Time Delay
- +/- 10 % of full scale 25 °C IEC 61812-1
- Height
- 90 mm
- Creepage Distance
- 4 kV/3 IEC 60664-1
- Maximum Delay Response
- 100 ms
- Control Type
- selector switch front panel
- Insulation Resistance
- 100 MOhm 500 V DC IEC 60664-1
- Maximum Power Consumption In W
- 0.6 W 24 V DC
- Maximum Switching Current
- 8 A AC/DC
- Contacts Material
- cadmium free
- Power Consumption In Va
- 0-32 VA 240 V AC
- Dielectric Strength
- 2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1
- Marking
- CE
- Voltage Range
- 0.85...1.1 Us
- Reset Time
- 120 ms on de-energisation typical
- Operating Rate In Hz
- 10 Hz
- Net Weight
- 0.07 kg
- Mounting Position
- any position in relation to normal vertical mounting plane
- Voltage Drift
- +/- 0.2 %/V
- Maximum Switching Voltage
- 250 V AC
- Connections - Terminals
- screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
- Functionality
- off-delay timing
- Contacts Type And Composition
- 1 C/O
- [Us] Rated Supply Voltage
- 24...240 V AC 50/60 Hz || 24 V DC
- Temperature Drift
- +/- 0.05 %/°C
- Local Signalling
- LED indicator on steady: relay energised, no timing in progress || LED indicator 80 % ON and 20 % OFF flashing: timing in progress || LED indicator 5 % ON and 95 % OFF pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L)
- Minimum Switching Current
- 10 mA 5 V DC
- Input Voltage
- 10 V
- Mounting Support
- 35 mm DIN rail conforming to IEC 60715
- Electrical Durability
- 100000 cycles resistive 8 A 250 V AC
- Mechanical Durability
- 10000000 cycles
- Compatibility Code
- RE17
- Breaking Capacity
- 2000 VA
- On-Load Factor
- 100 %
- Housing Material
- self-extinguishing
- Impulse Duration
- 100 ms with load in parallel typical || 30 ms typical
- Time Delay Type
- C
- [Uimp] Rated Impulse Withstand Voltage
- 5 kV 1.2/50 µs
- Depth
- 72 mm
- Tightening Torque
- 0.6-1 N.m IEC 60947-1
- Supply Frequency
- 50...60 Hz +/- 5 %
- Repeat Accuracy
- +/- 0.5 % IEC 61812-1
Environment
- Product Certifications
- cULus || GL || CSA
- Ambient Air Temperature For Operation
- -20-60 °C
- Standards
- IEC 61000-6-4 || IEC 61000-6-2 || IEC 61000-6-3 || 2004/108/EC || 2006/95/EC || IEC 61812-1 || IEC 61000-6-1
- Immunity To Microbreaks
- 20 ms
- Electromagnetic Compatibility
- electrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2 || electrostatic discharge immunity test 8 kV in air) level 3 IEC 61000-4-2 || susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) level 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 1 kV capacitive connecting clip) level 3 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV direct) level 3 IEC 61000-4-4 || 1.2/50 µs shock waves immunity test 1 kV differential mode) level 3 IEC 61000-4-5 || 1.2/50 µs shock waves immunity test 2 kV common mode) level 3 IEC 61000-4-5 || conducted RF disturbances 10 V 0.15...80 MHz) level 3 IEC 61000-4-6 || voltage dips and interruptions immunity test 0 % 1 cycle) IEC 61000-4-11 || voltage dips and interruptions immunity test 70 % 25/30 cycles) IEC 61000-4-11 || conducted and radiated emissionsclass B EN 55022
- Shock Resistance
- 15 gn 11 ms IEC 60068-2-27
- Vibration Resistance
- 20 m/s² 10-150 Hz)IEC 60068-2-6
- Ip Degree Of Protection
- IP20 IEC 60529 terminal block) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel)
- Ambient Air Temperature For Storage
- -30-60 °C
- Relative Humidity
- 93-93 % without condensation IEC 60068-2-30
Specifications
- Discrete Output Type
- relay
- Range Of Product
- Harmony Timer Relays
- Product Or Component Type
- single function relay
- Time Delay Range
- 6...60 s || 1...10 h || 1...10 min || 6...60 min || 0.1...1 s || 1...10 s || 10...100 h
- Nominal Output Current
- 8 A
- Width
- 17.5 mm
- Time Delay Type
- off-delay
- Device Short Name
- RE17R
Dokumente
Data Sheet
HerunterladenCAD Models
traceparts
HerunterladenAndere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges