- Power Consumption In W
- 1.5 W 240 V DC
- Safety Reliability Data
- B10d = 160000 || MTTFd = 171.2 years
- Contacts Type And Composition
- 1 C/O timed or instantaneous contact, cadmium free || 2 C/O timed contact, cadmium free
- Setting Accuracy Of Time Delay
- +/- 10 % of full scale 25 °C IEC 61812-1
- Creepage Distance
- 4 kV/3 IEC 60664-1
- Maximum Delay Response
- 100 ms
- Control Type
- rotary knob || diagnostic button || potentiometer external
- Insulation Resistance
- 100 MOhm 500 V DC IEC 60664-1
- Immunity To Microbreaks
- 10 ms
- Power Consumption In Va
- 3-3 VA 240 V AC
- Switching Capacity In Va
- 2000 VA
- Minimum Pulse Duration
- 100 ms with load in parallel || 30 ms
- Maximum Switching Current
- 8 A
- Function Available
- A- Power on-delay relay-2 C/O || At- Power on-delay relay w/ pause/summation (X1)-2 C/O || Aw- Power on-delay relay w/ retrigger/restart-2 C/O || C- Off-delay relay w/ control signal-2 C/O || Ct- Off-delay relay w/ control signal and pause/summation-2 C/O || D- Symmetrical flashing relay (starting pulse-off)-2 C/O || Dt- Symmetrical flashing relay (starting pulse-off) w/ pause/summation (X1)-2 C/O || Dw- Symmetrical flashing relay (starting pulse-off) w/ retrigger/restart-2 C/O || Di- Symmetrical flashing relay (starting pulse-on)-2 C/O || Dit- Symmetrical flashing relay (starting pulse-on) w/ pause/summation (X1)-2 C/O || Diw- Symmetrical flashing relay (starting pulse-on) w/ retrigger/restart-2 C/O || H- Interval relay-2 C/O || Ht- Interval relay w/ pause/summation (X1)-2 C/O || Hw- Interval relay w/ retrigger/restart-2 C/O || Qg- Star-delta relay (2 CO outputs w/ same common)-2 C/O || Qgt- Star-delta relay (2 CO outputs w/ same common) w/ pause/summation-2 C/O || Qt- Star-delta relay (2 CO outputs w/ split common)-2 C/O || Qtt- Star-delta relay (2 CO outputs w/ split common) w/ pause/summation (X1)-2 C/O || W- Interval relay w/ control signal off-2 C/O || Wt- Interval relay w/ control signal off and pause/summation-2 C/O
- Voltage Range
- 0.85...1.1 Us
- Net Weight
- 0.105 kg
- Mounting Position
- any position
- Voltage Drift
- +/- 0.2 %/V
- Reset Time
- 120 ms on de-energisation
- Maximum Switching Voltage
- 250 V AC
- Connections - Terminals
- screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
- [Us] Rated Supply Voltage
- 24...240 V AC/DC 50/60 Hz
- Temperature Drift
- +/- 0.05 %/°C
- Time Delay Range
- 3...30 min || 30...300 min || 0.3...3 s || 3...30 h || 10...100 s || 1...10 s || 0.05...1 s || 30...300 s || 30...300 h || 3...30 s
- Minimum Switching Current
- 10 mA 5 V DC
- Overvoltage Category
- III IEC 60664-1
- Input Voltage
- <= 2.4 V
- Mounting Support
- 35 mm DIN rail conforming to IEC 60715
- Electrical Durability
- 100000 cycles, 8 A at 250 V, AC-1 || 100000 cycles, 2 A at 24 V, DC-1
- Mechanical Durability
- 10000000 cycles
- Housing Material
- self-extinguishing
- Status Led
- Green LED backlight steady)dial pointer indication || Yellow LED steady)output relay energised || Yellow LED fast flashing)timing in progress and output relay de-energised || Yellow LED slow flashing)timing in progress and output relay energised
- [Uimp] Rated Impulse Withstand Voltage
- 5 kV 1.2-50 µs IEC 60664-1
- Width
- 22.5 mm
- Time Delay Type
- power on-delay || off-delay || symmetrical flashing || interval || star-delta
- Tightening Torque
- 0.6-1 N.m IEC 60947-1
- Supply Frequency
- 50...60 Hz +/- 5 %
- Repeat Accuracy
- +/- 0.5 % IEC 61812-1