Schneider Electric

TM262M35MESS8T

1 / 2
thumbnail
thumbnail

Beschreibung

Aktiv Reif
Modicon M262 logic/motion controllers are designed for performance-demanding machines, IIoT-ready and combine logic, motion and safety control applications. TM262M35MESS8T is specialized in the motion control of 4 fast digital inputs and 4 fast digital ouputs, 1 encoder input and up to 24 synchronized axes, embedding a safety control application according to SIL3. This motion controller embeds 3 Ethernet-based networks (EtherNet/IP, Modbus/TCP, Sercos), one serial port (Modbus, ASCII, Machine Expert protocols). Modicon M262 are logic/motion controllers with embedded cloud connectivity, figuring cybersecurity capabilities, supporting monitoring, analytics and predictive maintenance. It is powered with a non-isolated 24V DC power supply, has a built-in overload protection, embeds a dual-core processor, reaches a 5ns/instruction performance. This motion controller has one communication bus (Ethernet, CANopen), one IO bus, one IO port, one encoder connector. It measures 125mm width, 90mm depth, and 100 mm height. It weighs 0.670kg. This controller is designed for machinery requiring integrated IIoT connectivity or encrypted communication. Certified with CE, cULus HazLoc, RCM, EAC, Achilles L2, EU RO Mutual, Conform to UL 61010-1/-2-201, CSAC22.2 No. 61010-1/-2-201, ANSI/ISA 12-12-01, EN 61131-2. This controller is compatible with TMS CANopen/Ethernet smart communication module, Modicon TM3 IO expansion modules, configured by EcoStruxure Machine Expert. Modicon M262 logic controller installs on 35mm DIN rail with Clip-on locks. Modicon M262 logic/motion controllers are the IIoT-ready controllers for performance machines. Modicon M262 logic/motion controllers embed Industrial Internet of Things (IIoT) protocols and encryption to provide direct cloud connectivity & digital services.
Country of Origin
ID
Part Number
TM262M35MESS8T
Tariff Code
85371091
EAN
3606489604226
UNSPSC
32151705
Zahlungsmethoden:
Bestes Angebot von:
ITVertrauenswürdiger Automa.Net Lieferant
Verfügbarkeit:
9 Stk.
Auf Lager
Aktualisiert am: 20-11-2024
Garantie:
12 Monate
Geschätzte Lieferung:
Auf Anfrage
Zustand:
Neu versiegelt ab Werk
Neu versiegelt ab Werk - Ein brandneuer, unbenutzter, ungeöffneter, unbeschädigter Artikel in seiner original vom Hersteller versiegelten Verpackung.
Versandinformationen
Sicherer Zahlungsprozess
Rückgabe- und Erstattungsrichtlinien
Versandrichtlinien
Garantiebedingungen

Complementary

Discrete Input Logic
sink
Power Consumption In W
82 W
Data Backed Up
1 GB built-in flash memory backup of user programs
Discrete Output Type
transistor
Electrical Connection
removable spring terminal block for inputs and outputs || removable spring terminal block for connecting the 24 V DC power supply
Input Impedance
2.81 kOhm input
Maximum Cable Distance Between Devices
shielded cable <3 m fast input || shielded cable <3 m fast output || unshielded cable <50 m input || unshielded cable <50 m output || shielded cable <30 m RS485 link || shielded cable <15 m RS232
Height
100 mm
Discrete Output Logic
source
Discrete Input Voltage
24 V
Inrush Current
40 A
Encoder Type
incremental encoder
Discrete Output Number
4 transistor fast output
Discrete Input Voltage Type
DC
Communication Service
MQTTs || OPC UA server (Encrypt) || OPC UA client (Encrypt) || HTTPs Methods (API) || web server || web visu || TLS 1.2 || TLS 1.3 || SNTP || NTP client/server || FTP client/server || FTPs server || SQL client (remote access) || DHCP client || DHCP server || DNS client || POP3s client || SMTP client || SNMP client/server
Positioning Functions
libraries axes coordinated || libraries axes synchronous || Sercos 3 motion bus
Accuracy
+/- 0.1 % 0.02-0.1 kHz fast output || +/- 1 % 0.1-1 kHz fast output
Maximum Current Per Output Common
0.5 A Q0...Q3 fast output
Transmission Rate
115 kbit/s 15-15 m RS485 || 115 kbit/s 3-3 m RS232 || 480 Mbit/s 3-3 m USB || 10/100 Mbit/s Ethernet1 || 10/100/1000 Mbit/s Ethernet2
Clock Drift
<= 10 s/month 25-25 °C
Communication Port Protocol
EtherNet/IP adapter || EtherNet/IP scanner || Modbus TCP client/server || Modbus TCP IO scanner || Modbus TCP NVL || Ethernet RSTP || Modbus SL client/server || Modbus SL IO scanner || Modbus SL modem management || Machine Expert || ASCII manager || ASCII modem management || Sercos III master
Backup Time
1000 h 25 °C
Reset Time
200 ms automatic reset fast output
Cycle Time
0.5 ms
Maximum Number Of I/O Expansion Module
7 TM3 IO module (remote I/O-Architecture) || 7 TM3 IO module (local I/O-Architecture) || 64 TM3, TM5 or TM7 IO island (distributed I/O-Architecture)
Net Weight
0.67 kg
Discrete Output Current
0.5 A fast output Q0...Q3)
Application Structure
8 event tasks || 4 cyclic master tasks || 3 cyclic master tasks + 1 freewheeling task || 8 external event tasks
Voltage State 0 Guaranteed
<= 5 V DC
Configurable Filtering Time
0.001 ms fast input || 0.002 ms fast input || 0.005 ms fast input || 0.01 ms fast input || 0.05 ms fast input || 0.1 ms fast input || 0.5 ms fast input || 1 ms fast input || 4 ms fast input || 12 ms fast input
Output Voltage Limits
30 V DC
Discrete Output Voltage
24 V DC
Memory Capacity
32 MB program RAM || 32 MB OS/website RAM || 192 MB system memory RAM
Voltage State 1 Guaranteed
>= 15 V DC
Integrated Connection Type
Ethernet/Sercos 1 RJ45 10/100BASE-T || Ethernet 2 2 RJ45 100/1000BASE-T || serial link RJ45 RS232/RS485 || 1 encoder female SUB-D 15 RS422/SSI || Smart Communication Bus || TM3 IO bus || USB type mini B
Product Compatibility
external encoder 5/24 V DC no encoder power supply
Supply Voltage Limits
20.4-28.8 V DC
Mounting Support
top hat type TH35-15 rail IEC 60715 || top hat type TH35-7.5 rail IEC 60715 || plate or panel with fixing kit
Local Signalling
for PWR 1 LED (green/red) || for RUN 1 LED (green/red) || for ERROR (fault) 1 LED (green/red) || for stop forced 1 LED (green/red) || for I/O error (I/O) 1 LED (green/red) || for SD card activity 1 LED (green/orange) || for SL activity 1 LED (green/orange) || for ETH1 state 1 LED (green/red) || for ETH2 state 1 LED (green/red) || for EIP MS 1 LED (green/red) || for EIP NS 1 LED (green/red) || for Sercos 1 LED (green/red)
Surge Withstand
1 kV power lines (DC) common mode IEC 61000-4-5 || 1 kV shielded cable common mode IEC 61000-4-5 || 0.5 kV relay output differential mode IEC 61000-4-5 || 1 kV input common mode IEC 61000-4-5 || 1 kV transistor output common mode IEC 61000-4-5
Response Time
<= 1 µs turn-on, I0...I3 fast input || <= 1 µs turn-off, I0...I3 fast input || <= 1 µs turn-on, Q0...Q3 fast output || <= 1 µs turn-off, Q0...Q3 fast output
Discrete Input Current
7.5 mA fast input
Maximum Output Frequency
300 kHz
Execution Time For 1 Kinstruction
0.003 ms
Overvoltage Protection
with
Realtime Clock
with
Width
125 mm
Depth
90 mm
Maximum Tungsten Load
<1.5 W
Protection Type
short-circuit and overload protection with automatic reset || reverse polarity protection || short-circuit protection
Discrete Input Number
4 , discrete input fast input IEC 61131-2 Type 1
Maximum Leakage Current
10 µA output
Data Storage Equipment
<= 32 GB SDHC card optional)
Insulation
between fast input and internal logic 550 V AC || non-insulated between inputs || between output and internal logic 550 V AC || non-insulated between outputs || between input and output 550 V AC || between supply and internal logic 550 V AC || non-insulated between supply and ground
Maximum Number Of Connected Devices
EtherNet/IP <64 || Modbus TCP <64 || Modbus TCP/EtherNet/IP <128

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1904006EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1904006EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Specifications

[Us] Rated Supply Voltage
24 V DC - 15...20 %
Range Of Product
Logic/motion controller - Modicon M262
Product Or Component Type
motion controller
Discrete I/O Number
8
Upstream Connectivity
IIoT-ready machine to cloud || connected machine to plant

Environment

Product Certifications
CE || cULus || cULus HazLoc Class I Division 2 CSA 22-2 No 213 || RCM || EAC || Achilles || KC
Resistance To Conducted Disturbances
10 V 0.15...80 MHz IEC 61000-4-4 || 3 V 0.1...80 MHz || 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz)
Resistance To Electromagnetic Fields
10 V/m 80 MHz...1 GHz IEC 61000-4-3 || 3 V/m 1.4 GHz...2 GHz IEC 61000-4-3 || 1 V/m 2 GHz...3 GHz IEC 61000-4-3
Immunity To Microbreaks
0.01 ms
Storage Altitude
0-3000 m
Standards
UL 61010-1 || UL 61010-2-201 || CSA C22.2 No 61010-1 || CSA C22.2 No 61010-2-201 || CSA C22.2 No 213 || ANSI/ISA 12-12-01 || IEC 61131-2
Pollution Degree
2
Ambient Air Temperature For Operation
-20-60 °C horizontal installation) || -20-50 °C vertical installation) || -20-45 °C flat mounting)
Shock Resistance
15 gn 11 ms
Vibration Resistance
3.5 mm 2-8.4 Hz symmetrical rail || 1 gn 8.4-200 Hz symmetrical rail || 3.5 mm 2-8.4 Hz panel mounting || 1 gn 8.4-200 Hz panel mounting
Ambient Air Temperature For Storage
-40-85 °C
Relative Humidity
10-95 %, without condensation in operation) || 10-95 %, without condensation in storage)
Ip Degree Of Protection
IP20
Resistance To Electrostatic Discharge
4 kV on contact IEC 61000-4-2 || 8 kV on air IEC 61000-4-2
Resistance To Fast Transients
2 kV IEC 61000-4-4 power lines) || 1 kV IEC 61000-4-4 Ethernet line) || 1 kV IEC 61000-4-4 serial link) || 1 kV IEC 61000-4-4 input) || 1 kV IEC 61000-4-4 transistor output)
Operating Altitude
0...6561.68 ft (0...2000 m)
Electromagnetic Emission
conducted emissions 120...69 dBµV/m QP power lines)10-150 kHz IEC 55011 || conducted emissions 63 dBμV/m QP power lines)1.5-30 MHz IEC 55011 || radiated emissions 40 dBµV/m30-230 kHz IEC 55011 || conducted emissions 79...63 dBμV/m QP power lines)150-1500 kHz IEC 55011 || radiated emissions230-1000 MHz IEC 55011

CAD Models

traceparts
traceparts
Herunterladen