- Ambient Air Temperature For Operation
- -15-50 °C
- Storage Altitude
- 0-2000 m
- Electromagnetic Compatibility
- electrostatic discharge - test level: 8 kV (air discharge) conforming to IEC 61000-4-2 || electrostatic discharge - test level: 4 kV (contact discharge) conforming to IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m (80 MHz...1 GHz) conforming to IEC 61000-4-3 || radiated radio-frequency electromagnetic field immunity test - test level: 3 V/m (1.4...2 GHz) conforming to IEC 61000-4-3 || radiated radio-frequency electromagnetic field immunity test - test level: 1 V/m (2...3 GHz) conforming to IEC 61000-4-3 || magnetic field at power frequency - test level: 30 A/m (50/60 Hz) conforming to IEC 61000-4-8 || electrical fast transient/burst immunity test - test level: 1 kV conforming to IEC 61000-4-4 || surge immunity test - test level: 0.5 kV (common mode) conforming to IEC 61000-4-5 || surge immunity test - test level: 0.5 kV (differential mode) conforming to IEC 61000-4-5 || conducted RF disturbances - test level: 10 Vrms (0.15...80 MHz) conforming to IEC 61000-4-6 || disturbing field emission - test level: 10...150 kHz (power lines (DC)) conforming to IEC 55011 || disturbing field emission - test level: 120...69 dBµV/m QP (power lines (DC)) conforming to IEC 55011 || disturbing field emission - test level: 150...1500 kHz (power lines (DC)) conforming to IEC 55011 || disturbing field emission - test level: 1.5...30 kHz (power lines (DC)) conforming to IEC 55011 || disturbing field emission - test level: 30...230 MHz class A (10 m) conforming to IEC 55011 || disturbing field emission - test level: 230 MHz...1 GHZ class A (10 m) conforming to IEC 55011 || disturbing field emission - test level: 79...63 dBμV/m QP (power lines (DC)) conforming to IEC 55011 || disturbing field emission - test level: 63 dBμV/m QP (power lines (DC)) conforming to IEC 55011 || disturbing field emission - test level: 40 dBμV/m QP class A (10 m) conforming to IEC 55011 || disturbing field emission - test level: 47 dBμV/m QP class A (10 m) conforming to IEC 55011
- Shock Resistance
- 15 gn 11 ms
- Vibration Resistance
- 1.5 mm 3-150 Hz) || 2 gn
- Pollution Degree
- 2 IEC 60664-1
- Ambient Air Temperature For Storage
- -40-70 °C
- Environmental Characteristic
- corrosive gas free
- Relative Humidity
- 95-95 %, non-condensing transport) || 95-95 %, non-condensing storage) || 95-95 %, non-condensing operation)
- Ip Degree Of Protection
- front face IP65 || back part IP20
- Operating Altitude
- 0...6561.68 ft (0...2000 m)