Schneider Electric
XCKD2121M12
1 / 1
Beschreibung
Aktiv Reif
This XCKD compact format (CENELEC EN 50047) limit switch has a steel roller lever plunger with horizontal actuation and a Zamak body. This limit switch has a robust Zamak body and head, a modular design allowing easier maintenance and a compact CENELEC EN50047 format. It is ideal for all industrial machines like packaging, materials handling, conveyors, machining, food and beverage. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with CCC, EN/IEC 60947.-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508 standards and is also RoHS compliant. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head. It has a standard M12 connector, compatible with all existing market sensor cabling.- Country of Origin
- ID
- Part Number
- XCKD2121M12
- Tariff Code
- 85365080
- EAN
- 3389110198423
- UNSPSC
- 39122213
Zahlungsmethoden:
- Bestes Angebot von:
- Vertrauenswürdiger Automa.Net Lieferant
- Verfügbarkeit:
- 1 Stk.Auf LagerAktualisiert am: 08-11-2024
- Garantie:
- 12 Monate
- Geschätzte Lieferung:
- Auf Anfrage
- Zustand:
- Neuer Überschuss
Neuer Überschuss - Ein neuer, unbenutzter, unbeschädigter Artikel ohne Herstellergarantie. Der Artikel kann ohne Originalverpackung oder in Ersatzverpackung geliefert werden. Wenn vorhanden, könnte die Verpackung geöffnet worden sein.
Sicherer Zahlungsprozess
Rückgabe- und Erstattungsrichtlinien
Versandrichtlinien
Garantiebedingungen
Specifications
- Movement Of Operating Head
- linear
- Range Of Product
- Telemecanique Limit switches XC Standard
- Fixing Mode
- by the body
- Type Of Operator
- spring return roller lever plunger thermoplastic
- Sensor Design
- compact form E CENELEC EN 50047
- Product Or Component Type
- limit switch
- Head Material
- zamak
- Material
- metal
- Head Type
- plunger head
- Type Of Approach
- lateral approach, 1 direction
- Series Name
- standard format
- Contacts Type And Composition
- 1 NC + 1 NO
- Body Type
- fixed
- Contact Operation
- snap action
- Body Material
- zamak
- Device Short Name
- XCKD
- Number Of Poles
- 2
Contractual warranty
- Warranty
- 18 months
Complementary
- Height
- 65-65 mm
- Terminals Description Iso N°1
- (13-14)NO || (21-22)NC
- Short-Circuit Protection
- 4 A cartridge fuse gG
- Electrical Connection
- male connector M12, 5 pins
- [Ithe] Conventional Enclosed Thermal Current
- 4 A
- Net Weight
- 0.205 kg
- [Uimp] Rated Impulse Withstand Voltage
- 0.8 kV IEC 60664 || 0.8 kV IEC 60947-1
- Switch Actuation
- by 30° cam
- [Ui] Rated Insulation Voltage
- 60 V 3)IEC 60947-1
- Electrical Durability
- 5000000 cycles, DC-13, 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
- Positive Opening Minimum Force
- 18 N
- Positive Opening
- with
- Contacts Insulation Form
- Zb
- [Ie] Rated Operational Current
- 3 A 50 V, AC-15 EN/IEC 60947-5-1 appendix A || 0.27 A 50 V, DC-13 EN/IEC 60947-5-1 appendix A
- Mechanical Durability
- 15000000 cycles
- Maximum Actuation Speed
- 1 m/s
- Minimum Force For Tripping
- 6 N
- Width
- 31 mm
- Depth
- 30 mm
- Repeat Accuracy
- 0.1 mm on the tripping points with 1 million operating cycles
- Maximum Resistance Across Terminals
- 25 MOhm IEC 60255-7 category 3
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP110614EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- CSA || CCC || UL
- Ik Degree Of Protection
- IK06 EN 50102
- Ambient Air Temperature For Operation
- -25-70 °C
- Standards
- IEC 60947-5-1 || EN 60204-1 || UL 508 || EN 60947-5-1 || IEC 60204-1 || CSA C22.2 No 14
- Shock Resistance
- 50 gn 11 ms IEC 60068-2-27
- Vibration Resistance
- 25 gn 10-500 Hz)IEC 60068-2-6
- Ambient Air Temperature For Storage
- -40-70 °C
- Electrical Shock Protection Class
- class I IEC 61140 || class I NF C 20-030
- Protective Treatment
- TC
Andere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges