1 / 1
thumbnail

Beschreibung

Aktiv Reif
This XCKD compact format (CENELEC EN 50047) limit switch has a steel roller lever plunger with horizontal actuation and a Zamak body. This limit switch has a robust Zamak body and head, a modular design allowing easier maintenance and a compact CENELEC EN50047 format. It is ideal for all industrial machines like packaging, materials handling, conveyors, machining, food and beverage. It is fixed on the machine by its body, and has a typical 5 million cycles electrical durability in DC-13 utilization category. It complies with CCC, EN/IEC 60947.-5-1, CSA C22.2 No.14, EN/IEC 60204-1, UL 508 standards and is also RoHS compliant. Compatible with the well distributed range of common XCK heads, allowing quick replacement in case of damage. Variable composition design allows late modifications on the switch, for example change of connection type or head. It has a standard M12 connector, compatible with all existing market sensor cabling.
Country of Origin
ID
Part Number
XCKD2121M12
Tariff Code
85365080
EAN
3389110198423
UNSPSC
39122213
Zahlungsmethoden:
Bestes Angebot von:
DEVertrauenswürdiger Automa.Net Lieferant
Verfügbarkeit:
1 Stk.
Auf Lager
Aktualisiert am: 08-11-2024
Garantie:
12 Monate
Geschätzte Lieferung:
Auf Anfrage
Zustand:
Neuer Überschuss
Neuer Überschuss - Ein neuer, unbenutzter, unbeschädigter Artikel ohne Herstellergarantie. Der Artikel kann ohne Originalverpackung oder in Ersatzverpackung geliefert werden. Wenn vorhanden, könnte die Verpackung geöffnet worden sein.
Sicherer Zahlungsprozess
Rückgabe- und Erstattungsrichtlinien
Versandrichtlinien
Garantiebedingungen

Specifications

Movement Of Operating Head
linear
Range Of Product
Telemecanique Limit switches XC Standard
Fixing Mode
by the body
Type Of Operator
spring return roller lever plunger thermoplastic
Sensor Design
compact form E CENELEC EN 50047
Product Or Component Type
limit switch
Head Material
zamak
Material
metal
Head Type
plunger head
Type Of Approach
lateral approach, 1 direction
Series Name
standard format
Contacts Type And Composition
1 NC + 1 NO
Body Type
fixed
Contact Operation
snap action
Body Material
zamak
Device Short Name
XCKD
Number Of Poles
2

Contractual warranty

Warranty
18 months

Complementary

Height
65-65 mm
Terminals Description Iso N°1
(13-14)NO || (21-22)NC
Short-Circuit Protection
4 A cartridge fuse gG
Electrical Connection
male connector M12, 5 pins
[Ithe] Conventional Enclosed Thermal Current
4 A
Net Weight
0.205 kg
[Uimp] Rated Impulse Withstand Voltage
0.8 kV IEC 60664 || 0.8 kV IEC 60947-1
Switch Actuation
by 30° cam
[Ui] Rated Insulation Voltage
60 V 3)IEC 60947-1
Electrical Durability
5000000 cycles, DC-13, 24 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, 48 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Positive Opening Minimum Force
18 N
Positive Opening
with
Contacts Insulation Form
Zb
[Ie] Rated Operational Current
3 A 50 V, AC-15 EN/IEC 60947-5-1 appendix A || 0.27 A 50 V, DC-13 EN/IEC 60947-5-1 appendix A
Mechanical Durability
15000000 cycles
Maximum Actuation Speed
1 m/s
Minimum Force For Tripping
6 N
Width
31 mm
Depth
30 mm
Repeat Accuracy
0.1 mm on the tripping points with 1 million operating cycles
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110614EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA || CCC || UL
Ik Degree Of Protection
IK06 EN 50102
Ambient Air Temperature For Operation
-25-70 °C
Standards
IEC 60947-5-1 || EN 60204-1 || UL 508 || EN 60947-5-1 || IEC 60204-1 || CSA C22.2 No 14
Shock Resistance
50 gn 11 ms IEC 60068-2-27
Vibration Resistance
25 gn 10-500 Hz)IEC 60068-2-6
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class I IEC 61140 || class I NF C 20-030
Protective Treatment
TC