Limit switch, Limit switches XC Standard, XCKL, metal end plunger, 1NC+1 NO, snap action, Cable gland
XCKL110
  • Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
  • Wiederverkaufsrabatte bis zu 40%!
Sign-Up
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Angebot mit Herstellervorlaufzeit
Lieferung:1 - 2 Viele Arbeitstage
Bester Preis:
Preisanfrage senden

Additional Information

Part Number
XCKL110
UNSPSC
39122213
Tariff Code
8536509055
Country of Origin
FR

Specifications

Movement Of Operating Head
linear
Range Of Product
Telemecanique Limit switches XC Standard
Fixing Mode
by the body
Type Of Operator
spring return plunger metal
Cable Entry
1 metal cable gland entry 6-13.5 mm
Product Or Component Type
limit switch
Material
metal
Head Type
plunger head
Type Of Approach
vertical approach, 1 direction
Series Name
standard format
Contacts Type And Composition
1 NC + 1 NO
Body Type
fixed
Contact Operation
snap action
Body Material
zamak
Device Short Name
XCKL
Number Of Poles
2

Contractual warranty

Warranty
18 months

Complementary

Height
72-72 mm
Terminals Description Iso N°1
(13-14)NO || (21-22)NC
Short-Circuit Protection
10 A cartridge fuse gG
Minimum Actuation Speed
0.01 m/min
Electrical Connection
screw-clamp terminals 1 x 0.34...2 x 1.5 mm²
Number Of Steps
1
Net Weight
0.255 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV IEC 60664 || 6 kV IEC 60947-1
Switch Actuation
on end
[Ui] Rated Insulation Voltage
300 VUL 508 || 500 V 3)IEC 60947-1 || 300 VCSA C22.2 No 14
Electrical Durability
5000000 cycles, DC-13, inductive, 120 V, 4 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 24 V, 7 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C || 5000000 cycles, DC-13, inductive, 48 V, 10 W 60 cyc/mn 0.5 IEC 60947-5-1 appendix C
Positive Opening Minimum Force
45 N
Positive Opening
with
Contacts Insulation Form
Zb
Mechanical Durability
20000000 cycles
Maximum Actuation Speed
0.5 m/s
Minimum Force For Tripping
15 N
Contact Code Designation
A300, AC-15 (Ue = 240 V), Ie = 3 A EN/IEC 60947-5-1 appendix A || Q300, DC-13 (Ue = 250 V), Ie = 0.27 A EN/IEC 60947-5-1 appendix A
Width
52 mm
Depth
30 mm
[Ithe] Conventional Enclosed Thermal Current
10 A AC
Repeat Accuracy
0.05 mm on the tripping points with 1 million operating cycles
Maximum Resistance Across Terminals
25 MOhm IEC 60255-7 category 3

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP110614EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
CSA || UL
Ik Degree Of Protection
IK05 EN 50102
Ambient Air Temperature For Operation
-25-70 °C
Standards
IEC 60947-5-1 || UL 508 || EN 60947-5-1 || CSA C22.2 No 14 || IEC 60204-1 || EN 60204-1
Shock Resistance
50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
25 gn 10-500 Hz)EN/IEC 60068-2-6
Ip Degree Of Protection
IP66 conforming to EN/IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Electrical Shock Protection Class
class I IEC 61140 || class I NF C 20-030
Protective Treatment
TC

Dokumente

Data Sheet

Herunterladen

Ähnliche Produkte