- Maximum [Ie] Rated Operational Current
- 100 mA
- Height
- 51 mm
- Switching Frequency
- 150 Hz
- Short-Circuit Protection
- 500 mA external cartridge fuse gG (gl)
- Switching Capacity In Ma
- 5...100 mA
- [Sar] Assured Tripping Distance
- 15 mm
- Contacts Material
- rhodium
- Insulation Resistance
- 1000 MOhm
- Resistance Across Terminals
- 57 Ohm
- Net Weight
- 0.101 kg
- [Uimp] Rated Impulse Withstand Voltage
- 2.5 kV EN/IEC 60947-5-1
- Maximum Switching Voltage
- 100 V DC
- [Sa] Assured Operating Distance
- 5 mm
- Cable Material
- PVC
- Breaking Capacity
- 3 VA
- Safety Reliability Data
- B10d = 50000000 value given for a life time of 20 years limited by mechanical or contact wear
- Enclosure Material
- thermoplastic PBT
- Width
- 16 mm
- Depth
- 7 mm
- Electrical Durability
- 1200000 cycles
- Safety Level
- can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508