Schneider Electric
XMEP5K0PT730
1 / 1
Beschreibung
Aktiv Reif
- Country of Origin
- CH
- Part Number
- XMEP5K0PT730
- Tariff Code
- 90262020
- EAN
- 3389119637008
- UNSPSC
- 41111927
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Specifications
- Pressure Sensor Type
- pressure transmitter
- Pressure Sensor Size
- 5000 psi
- Analogue Output Function
- 0...10 V, 3-wire
- Type Of Output Signal
- analogue
- Controlled Fluid
- fresh water 0-125 °C) || air -40-125 °C) || hydraulic oil -40-125 °C)
- Range Of Product
- Telemecanique Pressure sensors XM
- Electrical Connection
- DEUTSCH connector DT04-3P 3 pins
- Quantity Per Set
- set of 1
- Electrical Circuit Type
- control circuit
- Product Or Component Type
- electronic pressure sensors
- Type Of Packing
- individual
- [Us] Rated Supply Voltage
- 24 V DC SELV 12-36 V)
- Local Display
- without
- Pressure Sensor Name
- XMEP
- Current Consumption
- < 7 mA
- Fluid Connection Type
- 1/4" - 18 NPT (male)
Complementary
- Accuracy
- 0.1 % of the measuring range
- Diameter
- 26 mm
- [Uimp] Rated Impulse Withstand Voltage
- 0.5 kV
- Repeat Accuracy
- +/- 0.5 % of the measuring range
- Mechanical Durability
- 10000000 cycles
- Drift Of The Zero Point
- +/- 0.02 % of measuring range/°K
- Operating Position
- any position
- Measurement Accuracy
- +/- 0.5 % of the measuring range
- Electromagnetic Compatibility
- electrostatic discharge immunity test ISO 10605 criteria A 15 kV air, 15 kV contact || susceptibility to electromagnetic fields ISO 11452-2 criteria A 100 V/m 200…2000 MHz || susceptibility to electromagnetic fields ISO 11452-4 criteria A 100 mA 20…400 MHz || susceptibility to conducted disturbances EN/IEC 61000-4-6 criteria A 30 V 0.15...80 MHz || electrical fast transient/burst immunity test EN/IEC 61000-4-4 criteria A 4 kV || susceptibility to conducted transient disturbances ISO 7637-2 criteria B level 3
- Protection Type
- reverse polarity || load short-circuit
- Drift Of The Sensitivity
- +/- 0.02 % of measuring range/°K
- Maximum Permissible Accidental Pressure
- 15000 psi
- Materials In Contact With Fluid
- stainless steel AISI 316L
- Length
- 63.4 mm
- Destruction Pressure
- 30000 psi
- Net Weight
- 0.098 kg
- Response Time On Output
- <= 2 ms 10...90 % of full scale
- Pressure Setting Range
- 0-5000 psi
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1511013EN
- Sustainable Offer Status
- Green Premium product
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Environment
- Product Certifications
- E2 || cULus || CE
- Ambient Air Temperature For Operation
- -40-100 °C
- Ambient Air Temperature For Storage
- -50-100 °C
- Standards
- EN/IEC 61326-2-3 || UL 61010-1 || ECE 10R-5 || ISO 14982 || ISO 13766 || EN 13309
- Shock Resistance
- 50 gn 11 ms EN/IEC 60068-2-27
- Vibration Resistance
- 12 gn sinus 20-520 Hz) test 4 ISO 16750-3 || 18 gn random 10-2000 Hz) test 4 ISO 16750-3
- Ip Degree Of Protection
- IP65 conforming to EN/IEC 60529 || IP67 conforming to EN/IEC 60529 || IP69K conforming to EN/IEC 60529