Schneider Electric
XMLB002A2S12
1 / 1
Beschreibung
This XMLB electromechanical pressure switch has an adjustable differential for regulation of 2 thresholds and a zinc alloy body with a range scale window. This pressure switch is designed for regulation of pressure between 2 thresholds for air, fresh water and hydraulic oils at temperatures up to 70°C. It is fixed directly on tubage. It provides zinc alloy enclosure for robust performance. 8 million cycles mechanical durability for minimum required maintenance on your pressurized fluid circuits. It complies with CCC, EN/IEC 60947-5-1, CSA C22.2 No.14, LROS, UL 508, EAC, BV.- Country of Origin
- FR
- Part Number
- XMLB002A2S12
- Tariff Code
- 90322000
- EAN
- 3389110754629
- UNSPSC
- 39122210
Zahlungsmethoden:
- Bestes Angebot von:
- Vertrauenswürdiger Automa.Net Lieferant
- Verfügbarkeit:
- 1 Stk.Auf LagerAktualisiert am: 08-11-2024
- Garantie:
- 12 Monate
- Geschätzte Lieferung:
- Auf Anfrage
- Zustand:
- Neuer Überschuss
Neuer Überschuss - Ein neuer, unbenutzter, unbeschädigter Artikel ohne Herstellergarantie. Der Artikel kann ohne Originalverpackung oder in Ersatzverpackung geliefert werden. Wenn vorhanden, könnte die Verpackung geöffnet worden sein.
Sicherer Zahlungsprozess
Rückgabe- und Erstattungsrichtlinien
Versandrichtlinien
Garantiebedingungen
Specifications
- Contacts Type And Composition
- 1 C/O
- Pressure Sensor Type
- electromechanical pressure sensor
- Pressure Actuator
- diaphragm
- Electrical Connection
- screw-clamps terminals, 1 x 0.5...2 x 2.5 mm²
- Range Of Product
- Telemecanique Pressure sensors XM
- Line Rated Current
- 3 A, B300, AC-15 (Ue = 120 V)EN/IEC 60947-5-1 || 1.5 A, B300, AC-15 (Ue = 240 V)EN/IEC 60947-5-1 || 0.1 A, R300, DC-13 (Ue = 250 V)EN/IEC 60947-5-1
- Pressure Switch Type Of Operation
- regulation between 2 thresholds
- Cable Entry
- cable gland 7-13 mm
- Product Or Component Type
- electromechanical pressure sensor
- Adjustable Range Of Switching Point On Falling Pressure
- 0.14-2.29 bar
- Materials In Contact With Fluid
- nitrile || zinc alloy
- Local Display
- with
- Fluid Connection Type
- G 1/4 (female) ISO 228
- Pressure Sensor Size
- 2.5 bar
- Controlled Fluid
- air 0-70 °C) || fresh water 0-70 °C) || hydraulic oil 0-70 °C)
- Awg Gauge
- AWG 20...AWG 14
- Scale Type
- adjustable differential
- Electrical Circuit Type
- control circuit
- Enclosure Material
- zinc alloy
- Adjustable Range Of Switching Point On Rising Pressure
- 0.3-2.5 bar
- Maximum Permissible Accidental Pressure
- 9 bar
- Possible Differential Maximum At High Setting
- 1.75 bar
- Destruction Pressure
- 18 bar
- Device Short Name
- XMLB
Contractual warranty
- Warranty
- 18 months
Complementary
- Repeat Accuracy
- 2 %
- Height
- 113 mm
- Terminal Block Type
- 4 terminals
- Short-Circuit Protection
- 10 A cartridge fuse gG (gl)
- Contacts Material
- silver contacts
- Possible Differential Minimum At High Setting
- 0.21 bar - 0.03 bar, + 0.05 bar)
- Auxiliary Contacts Operation
- snap action
- Net Weight
- 1.015 kg
- [Uimp] Rated Impulse Withstand Voltage
- 6 kV EN/IEC 60947-1
- Maximum Permissible Pressure - Per Cycle
- 5 bar
- Maximum Operating Rate
- 120 cyc/mn
- [Ui] Rated Insulation Voltage
- 300 V UL 508 || 500 V EN/IEC 60947-1 || 300 V CSA C22.2 No 14
- Setting
- external
- Mechanical Durability
- 8000000 cycles
- Width
- 55 mm
- Depth
- 75 mm
- Maximum Resistance Across Terminals
- 25 mOhm IEC 255-7 category 3 || 25 mOhm NF C 93-050 method A
- Possible Differential Minimum At Low Setting
- 0.16 bar - 0.03 bar, + 0.05 bar)
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP110914EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- BV || CSA || LROS (Lloyds register of shipping) || CCC || UL || EAC
- Ambient Air Temperature For Operation
- -25-70 °C
- Standards
- EN/IEC 60947-5-1 || UL 508 || CE || CSA C22.2 No 14
- Vibration Resistance
- 4 gn 30-500 Hz)IEC 60068-2-6
- Shock Resistance
- 50 gn IEC 60068-2-27
- Ip Degree Of Protection
- IP66 conforming to EN/IEC 60529
- Ambient Air Temperature For Storage
- -40-70 °C
- Protective Treatment
- TC standard version
- Operating Position
- any position
- Electrical Shock Protection Class
- class I IEC 1140 || class I IEC 536 || class I NF C 20-030
Andere Kategorien
AktuatorenBlöckeKabel, Rohre & SchläucheKompressorenKontrolleKupplungen & FittingsZylinder & KolbenElektronikFilterHVACIndustrie-PCs & HMIsBeleuchtungLineartechnikMotorenStromversorgungLeistungsübertragungPumpen & VentileErneuerbare energieRobotikDichtungen, Ringe & VerbinderSensoren und MessgeräteWerkzeuge und ZubehörCNCSonstiges