Safety module, Harmony Safety Automation, Cat.4, Expansion use with Universal range, 48-240v AC/DC, spring
XPSUEP34AC
XPSUEP34AC
XPSUEP34AC
XPSUEP34AC
  • Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
  • Wiederverkaufsrabatte bis zu 40%!
Sign-Up
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Angebot mit Herstellervorlaufzeit
Lieferung:Auf Anfrage
Bester Preis:
€71.64

Additional Information

Part Number
XPSUEP34AC
UNSPSC
32151705
Tariff Code
8536490055
Country of Origin
ID

Complementary

Height
100 mm
Mounting Support
35 mm symmetrical DIN rail
Minimum Output Voltage
12 V relay output
Minimum Output Current
10 mA relay output
[Ith] Conventional Free Air Thermal Current
8 A
Associated Fuse Rating
10 A gG NO relay output circuit IEC 60947-1 || 4 A gG NC relay output circuit IEC 60947-1
[Uimp] Rated Impulse Withstand Voltage
4 kV II IEC 60947-1
Net Weight
0.200 kg
Number Of Inputs
0 extension bus 24 V DC 5
Input Compatibility
normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || 3-wire proximity sensors PNP
Power Consumption In Va
6.5 VA 240 V AC 50/60 Hz
[Ie] Rated Operational Current
5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact
Auxiliary Contact Composition
4 NO redundant || 2 NC single
[Ui] Rated Insulation Voltage
250 V 2)IEC 60947-1
Power Consumption In W
2 W 48 V DC
Maximum Line Resistance
60 Ohm
Local Signalling
for power ON LED (green) || for error LED (red) || for safety output status LED (yellow)
Input Protection Type
internal, electronic
Width
22.5 mm
Depth
120 mm
Maximum Response Time On Input Open
20 ms

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1811003EN
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
X
Circularity Profile
ENVEOLI1811003EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
TÜV || cULus
Ip Degree Of Protection
IP20 terminals)IEC 60529 || IP40 housing)IEC 60529 || IP54 mounting area)IEC 60529
Standards
IEC 60947-5-1 || IEC 61508-1 functional safety standard || IEC 61508-2 functional safety standard || IEC 61508-3 functional safety standard || IEC 61508-4 functional safety standard || IEC 61508-5 functional safety standard || IEC 61508-6 functional safety standard || IEC 61508-7 functional safety standard || ISO 13849-1 functional safety standard || IEC 62061 functional safety standard
Ambient Air Temperature For Storage
-25-85 °C
Relative Humidity
5-95 % non-condensing

Specifications

[Us] Rated Supply Voltage
48...240 V AC/DC - 10...10 %
Range Of Product
Harmony Safety Automation
Product Or Component Type
safety module
Safety Module Name
XPSUEP
Connections - Terminals
removable spring terminal block, 0.2...2.5 mm² solid or flexible || removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor || removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor || removable spring terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel || removable spring terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel
Safety Module Application
for extending number of safety contacts
Safety Reliability Data
MTTFd > 30 years ISO 13849-1 || Dcavg >= 99 % ISO 13849-1 || PFHd = 1.61E-09 ISO 13849-1 || HFT = 1 IEC 62061 || PFHd = 1.61E-09 IEC 62061 || SFF > 99% IEC 62061 || HFT = 1 IEC 61508-1 || PFHd = 1.61E-09 IEC 61508-1 || SFF > 99% IEC 61508-1 || type = B IEC 61508-1
Electrical Circuit Type
addition to Preventa XPSU base module
Function Of Module
safety output extension
Safety Level
can reach PL e/category 4 for normally open relay contact ISO 13849-1 || can reach SILCL 3 for normally open relay contact IEC 62061 || can reach SIL 3 for normally open relay contact IEC 61508 || can reach PL c/category 1 for normally closed relay contact ISO 13849-1 || can reach SILCL 1 for normally closed relay contact IEC 62061 || can reach SIL 1 for normally closed relay contact IEC 61508