Schneider Electric
XUDA1PSML2
Photoelectric sensors XU, XUD, precabled, PVC, PNP, discrete solid state
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Insgesamt 6 Parts In-Stock von 12 Distributors
Produktbedingungen:
Angebot mit Herstellervorlaufzeit
Lieferung:Auf Anfrage
Bester Preis:
Preisanfrage senden
Additional Information
- Part Number
- XUDA1PSML2
- UNSPSC
- 39121528
- Tariff Code
- 8541498000
- Country of Origin
- HU
Specifications
- Range Of Product
- Telemecanique Photoelectric sensors XU
- Sensor Name
- XUD
- Series Name
- Application assembly
- Specific Application Of Photoelectric Detector
- object
Contractual warranty
- Warranty
- 18 months
Complementary
- Current Consumption
- <= 50 mA no-load
- Electrical Connection
- cable
- Discrete Output Type
- PNP
- Discrete Output Function
- 1 NO or 1 NC programmable
- Height
- 65 mm
- Switching Frequency
- <= 1 kHz
- Maximum Delay Response
- 0.5 ms
- Type Of Output Signal
- discrete
- Status Led
- instability 1 LED red) || output state 1 LED yellow)
- Setting-Up
- sensitivity adjustment with teach mode
- Lens Material
- PMMA
- Cable Length
- 2 m
- Maximum Voltage Drop
- <2 V closed)
- Net Weight
- 0.04 kg
- Wiring Technique
- 3-wire
- Maximum Delay Recovery
- 0.5 ms
- Maximum Delay First Up
- 120 ms
- Supply Voltage Limits
- 10.8-26.4 V DC
- Cable Material
- PVC
- Switching Capacity In Ma
- <= 100 mA overload protection) || <= 100 mA short-circuit protection)
- Sensor Design
- fiber design
- Enclosure Material
- PBT
- Supply Circuit Type
- DC
- Electronic Sensor Type
- photo-electric sensor
- Width
- 40 mm
- Output Type
- solid state
- Depth
- 10 mm
- Product Compatibility
- glass or plastic fibre optics 1 mm or 2.2 mm
- Add On Output
- without
- [Us] Rated Supply Voltage
- 12...24 V DC reverse polarity protection
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc
- Yes
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- cULus || CE
- Ambient Air Temperature For Operation
- -10-55 °C
- Ip Degree Of Protection
- IP64 optic fiber Ø 1 mm IEC 529 || IP65 optic fiber Ø 2 mm IEC 529
- Shock Resistance
- 30 gn 11 ms) IEC 60068-2-27
- Vibration Resistance
- +/-0.5 mm 10-55 Hz)IEC 60068-2-6 || 7 gn 10-55 Hz)IEC 60068-2-6
- Emission
- red
- Ambient Air Temperature For Storage
- -30-70 °C
- Interference Protection
- without