1 / 1
thumbnail

Beschreibung

Aktiv Reif
Country of Origin
MA
Part Number
XY2CEDA596
Tariff Code
85365080
EAN
3606480880032
UNSPSC
39122213
Zahlungsmethoden:
Bestes Angebot von:
SKVertrauenswürdiger Automa.Net Lieferant
Verfügbarkeit:
10 Stk.
Auf Lager
Aktualisiert am: 08-11-2024
Garantie:
12 Monate
Geschätzte Lieferung:
Auf Anfrage
Zustand:
Neu versiegelt ab Werk
Neu versiegelt ab Werk - Ein brandneuer, unbenutzter, ungeöffneter, unbeschädigter Artikel in seiner original vom Hersteller versiegelten Verpackung.
Sicherer Zahlungsprozess
Rückgabe- und Erstattungsrichtlinien
Versandrichtlinien
Garantiebedingungen

Specifications

Housing Colour
red RAL 3000
Range Of Product
Telemecanique Emergency stop rope pull switches XY2C
Overvoltage Category
class I EN/IEC 61140
Product Or Component Type
dual emergency stop rope pull switch
Device Short Name
XY2CED

Complementary

Trigger Cable Maximum Length
2 x 100 m
Connections - Terminals
screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
Reset
by key-release push-button
Contacts Type And Composition
2 x (1 NC + 1 NO)
Number Of Cables
2
Terminals Description Iso N°1
(13-14)NO || (21-22)NC
[Ui] Rated Insulation Voltage
500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
Key Number
455
Short-Circuit Protection
10 A cartridge fuse gG EN/IEC 60269
Bellow Material
nitril
[Ie] Rated Operational Current
3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Contact Operation
slow-break
Distance Between Cable Supports
3-5 m
Mechanical Durability
60000 cycles
Positive Opening
with EN/IEC 60947-5-1
Cable Entry Number
3 plain hole Pg 13.5 or ISO M20 cable gland
Compatibility Code
XY2CED
Body Material
zamak
[Ithe] Conventional Enclosed Thermal Current
10 A
Trigger Cable Anchor Point
RH and LH sides
Safety Reliability Data
B10d = 300000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Marking
CE
Cover Material
stainless steel
Local Signalling
with pilot light, yellow, 24...130 V
Net Weight
1.9 kg
Tightening Torque
0.8-1.2 N.m
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-1
Maximum Resistance Across Terminals
25 MOhm EN/IEC 60255-7 category 3
Safety Level
can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111159EN
Sustainable Offer Status
Green Premium product
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Environment

Ambient Air Temperature For Operation
-25-70 °C
Ambient Air Temperature For Storage
-40-70 °C
Standards
EN/IEC 60204-1 || EN/IEC 60947-5-1 || EN/ISO 13850 || work equipment directive 2009/104/EC || CSA C22.2 No 14 || EN/IEC 60947-5-5 || machinery directive 2006/42/EC || UL 508
Product Certifications
UL category NISD emergency stop devices || CSA || CCC || EAC
Shock Resistance
50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
10 gn 10-300 Hz)EN/IEC 60068-2-6
Protective Treatment
TC
Ip Degree Of Protection
IP65 IEC 60529