Latching emergency stop rope pull switch, Telemecanique rope pull switches XY2C, e XY2CJ, left side, 1NC+1 NO, Pg13.5
XY2CJL15
  • Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
  • Wiederverkaufsrabatte bis zu 40%!
Sign-Up
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Angebot mit Herstellervorlaufzeit
Lieferung:Auf Anfrage
Bester Preis:
€25.90

Additional Information

Part Number
XY2CJL15
UNSPSC
39122239
Tariff Code
8536509055
Country of Origin
ID

Specifications

Range Of Product
Telemecanique Emergency stop rope pull switches XY2C
Product Or Component Type
latching emergency stop rope pull switch
Housing Colour
red RAL 3000
Overvoltage Category
class I EN/IEC 61140
Device Short Name
XY2C

Complementary

Reset
by pull button
Number Of Cables
1
Terminals Description Iso N°1
(21-22)NC || (13-14)NO
Short-Circuit Protection
10 A cartridge fuse gG EN/IEC 60269
Positive Opening
with EN/IEC 60947-5-1
[Ithe] Conventional Enclosed Thermal Current
10 A
Marking
CE
Local Signalling
color indicator
Net Weight
0.669 kg
[Uimp] Rated Impulse Withstand Voltage
6 kV EN/IEC 60947-1
Trigger Cable Maximum Length
30 m
Connections - Terminals
screw clamp terminal, 1 x 0.5...2 x 1.5 mm²
Contacts Type And Composition
1 NC + 1 NO
[Ui] Rated Insulation Voltage
500 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
[Ie] Rated Operational Current
3 A 240 V, AC-15, A300 EN/IEC 60947-5-1 appendix A || 0.27 A 250 V, DC-13, Q300 EN/IEC 60947-5-1 appendix A
Contact Operation
slow-break
Distance Between Cable Supports
5-5 m
Mechanical Durability
100000 cycles
Cable Entry Number
1 tapped entry Pg 13.5 cable gland
Compatibility Code
XY2CJ
Body Material
zamak
Trigger Cable Anchor Point
LH side
Safety Reliability Data
B10d = 500000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
Cover Material
galvanised steel
Tightening Torque
0.8-1.2 N.m
Maximum Resistance Across Terminals
25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
Safety Level
can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1407002EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Ambient Air Temperature For Operation
-25-70 °C
Standards
EN/IEC 60947-5-1 || UL 508 || EN/IEC 60947-5-5 || work equipment directive 2009/104/EC || EN/IEC 60204-1 || CSA C22.2 No 14 || EN/ISO 13850 || machinery directive 2006/42/EC
Product Certifications
UL category NISD emergency stop devices || CSA || CCC || EAC
Shock Resistance
50 gn 11 ms EN/IEC 60068-2-27
Vibration Resistance
10 gn 10-150 Hz)EN/IEC 60068-2-6
Ip Degree Of Protection
IP66 IEC 60529 || IP67 IEC 60529
Ambient Air Temperature For Storage
-40-70 °C
Protective Treatment
TC