Beschreibung
Aktiv Reif
This product is part of the XY2C range, an offer of emergency stop rope pull switches. It is ideal for all machines requiring stopping of dangerous movement in the immediate vicinity of the machine. It is suitable for applications such as woodworking machines, shears, conveyor systems, printing machines, textile machines etc. This emergency stop rope pull switch has 2 normally closed and 1 normally opened, slow-break contacts with positive opening operation. It is a switch with a rated operational current of 0.1A at 250V AC, 1.5A at 240V AC and a conventional enclosed thermal current of 6A. It is furnished with screw clamp terminals for electrical connection. Switch has one 1/2 inch NPT tapped conduit entries. The trigger cable anchor point at right and left hand side. Switch is has a pull reset pushbutton. It offers long mechanical durability which is about 100000 operating cycles. It is an IP66 and IP67 rated product. The casing is made of Zamak (red) with galvanized steel cover. Its dimensions are 1.57 inches (Width) x 2.53 inches (Depth) x 7.55 inches (Height). This product meets UL508, CSA C22.2 No 14, EN/ISO 13850, EN/IEC 60947-5-1, EN/IEC 60204-1, EN/IEC 60947-5-5, machinery directive 2006/42/EC and work equipment directive 2009/104/EC standards. This product is certified by UL, CSA, EAC and CCC. XY2 range emergency stop rope pull switch is intended for all machines requiring stopping of a dangerous movement in the immediate vicinity of the machine.- Country of Origin
- ID
- Part Number
- XY2CJS19H7
- Tariff Code
- 85365080
- EAN
- 3389119619561
- UNSPSC
- 39122213
Zahlungsmethoden:
- Bestes Angebot von:
- Vertrauenswürdiger Automa.Net Lieferant
- Verfügbarkeit:
- 1 Stk.Auf LagerAktualisiert am: 21-10-2024
- Geschätzte Lieferung:
- Auf Anfrage
- Zustand:
- Neuer Überschuss
Neuer Überschuss - Ein neuer, unbenutzter, unbeschädigter Artikel ohne Herstellergarantie. Der Artikel kann ohne Originalverpackung oder in Ersatzverpackung geliefert werden. Wenn vorhanden, könnte die Verpackung geöffnet worden sein.
Sicherer Zahlungsprozess
Rückgabe- und Erstattungsrichtlinien
Versandrichtlinien
Garantiebedingungen
Specifications
- Housing Colour
- red RAL 3000
- Range Of Product
- Telemecanique Emergency stop rope pull switches XY2C
- Overvoltage Category
- class I EN/IEC 61140
- Product Or Component Type
- latching emergency stop rope pull switch
- Device Short Name
- XY2C
Complementary
- Trigger Cable Maximum Length
- 20 m
- Connections - Terminals
- screw clamp terminal, 1 x 0.34...1 x 1 mm² || screw clamp terminal, 1 x 0.34...2 x 0.75 mm²
- Reset
- by pull button
- Contacts Type And Composition
- 2 NC + 1 NO
- Number Of Cables
- 1
- Terminals Description Iso N°1
- (13-14)NO || (31-32)NC || (21-22)NC
- [Ui] Rated Insulation Voltage
- 400 V 3)EN/IEC 60947-1 || 300 VUL 508 || 300 VCSA C22.2 No 14
- Short-Circuit Protection
- 6 A cartridge fuse gG EN/IEC 60269
- [Ie] Rated Operational Current
- 0.1 A 250 V, DC-13, R300 EN/IEC 60947-5-1 appendix A || 1.5 A 240 V, AC-15, B300 EN/IEC 60947-5-1 appendix A
- Contact Operation
- slow-break
- Distance Between Cable Supports
- 5-5 m
- Mechanical Durability
- 100000 cycles
- Positive Opening
- with EN/IEC 60947-5-1
- Cable Entry Number
- 1 tapped entry 1/2" NPT conduit entry
- Compatibility Code
- XY2CJ
- Body Material
- zamak
- [Ithe] Conventional Enclosed Thermal Current
- 6 A
- Trigger Cable Anchor Point
- RH or LH side
- Safety Reliability Data
- B10d = 500000 value given for a life time of 20 years limited by mechanical or contact wear IEC 60947-5-5
- Marking
- CE
- Head Material
- PA (polyamide)
- Cover Material
- galvanised steel
- Local Signalling
- color indicator
- Net Weight
- 0.455 kg
- Tightening Torque
- 0.8-1.2 N.m
- [Uimp] Rated Impulse Withstand Voltage
- 4 kV EN/IEC 60947-1
- Maximum Resistance Across Terminals
- 25 MOhm EN/IEC 60255-7 category 3 || 25 MOhm NF C 93-050 method A
- Safety Level
- can reach PL = e with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach category 4 with the appropriate monitoring system and correctly wired EN/ISO 13849-1 || can reach SIL 3 with the appropriate monitoring system and correctly wired EN/IEC 61508
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1407003EN
- Sustainable Offer Status
- Green Premium product
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Environment
- Ambient Air Temperature For Operation
- -25-70 °C
- Ambient Air Temperature For Storage
- -40-70 °C
- Standards
- EN/IEC 60947-5-5 || CSA C22.2 No 14 || work equipment directive 2009/104/EC || EN/IEC 60947-5-1 || machinery directive 2006/42/EC || UL 508 || EN/ISO 13850 || EN/IEC 60204-1
- Product Certifications
- UL category NISD emergency stop devices || CSA || CCC || EAC
- Shock Resistance
- 50 gn 11 ms EN/IEC 60068-2-27
- Vibration Resistance
- 10 gn 10-150 Hz)EN/IEC 60068-2-6
- Protective Treatment
- TC
- Ip Degree Of Protection
- IP66 IEC 60529 || IP67 IEC 60529