Electronic pressure sensors, Pressure sensors XM, Display & switch ZMLP, 24 VDC, 4...20 mA, NPN, hysteresis, M12
ZMLPA1N2SH
  • Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
  • Wiederverkaufsrabatte bis zu 40%!
Sign-Up
Preisanfrage senden
1
Zahlungsmöglichkeiten:

Specifications

Range Of Product
OsiSense XM
Product Or Component Type
electronic pressure sensors
Device Short Name
ZMLP

Complementary

Display Accuracy
<= 1 % of the measuring range
Adjustable Range Of Switching Point On Falling Pressure
2-95 % of selected display range
Electrical Connection
female connector M12, 2 pins || male connector M12, 4 pins
Height
77 mm
Accuracy
<= - 0.1 % of the measuring range
Type Of Output Signal
analogue + discrete
Maximum Voltage Drop
2 V
Switching Function
hysteresis
Display Range
-14.5...6000
Maximum Switching Current
200 mA
Marking
CE
Net Weight
0.103 kg
Current Consumption
<= 50 mA
Maximum Delay First Up
100 ms
Response Time
300 ms
Local Signalling
for light ON when switch is actuated 1 LED (yellow)
Mechanical Durability
10000000 cycles
Housing Material
PBT Valox
Operating Position
any position
Measurement Accuracy
<= 1 % of the measuring range
Protection Type
short-circuit protection || overload protection || reverse polarity || overvoltage protection
Width
41 mm
Display Type
4 digits 7 segments
Front Material
polyester
[Uimp] Rated Impulse Withstand Voltage
0.5 kV DC
Depth
42 mm
Minimum Differential Travel
3 % of selected display range
Adjustable Range Of Switching Point On Rising Pressure
5-98 % of selected display range
[Us] Rated Supply Voltage
24 V DC SELV 17-33 V)
Analogue Output Function
4...20 mA
Response Time On Output
<= 3 ms analog output || <= 3 ms discrete output
Discrete Output Type
solid state NPN, NO/NC programmable

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1401011EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Circularity Profile
ENVEOLI1401011EN
Eu Rohs Directive
Pro-active compliance (Product out of EU RoHS legal scope)

Environment

Product Certifications
EAC || cULus
Ambient Air Temperature For Operation
-25-70 °C
Standards
EN/IEC 61000-6-4 || UL 508 || EN/IEC 61000-6-2
Electromagnetic Compatibility
immunity to conducted RF disturbances 10 V 0.15...80 MHz EN/IEC 61000-4-6 || surge immunity test 1 kV EN/IEC 61000-4-5 || electrical fast transient/burst immunity test 2 kV EN/IEC 61000-4-4 || susceptibility to electromagnetic fields 10 V/m 80...2000 MHz EN/IEC 61000-4-3 || electrostatic discharge immunity test 8 kV air, 4 kV contact EN/IEC 61000-4-2
Shock Resistance
25 gn EN/IEC 60068-2-27
Vibration Resistance
5 gn 10-2000 Hz)EN/IEC 60068-2-6
Ip Degree Of Protection
IP67 conforming to EN/IEC 60529 || IP65 conforming to EN/IEC 60529 || IP69K conforming to DIN 40050
Ambient Air Temperature For Storage
-30-80 °C

Dokumente

Data Sheet

Herunterladen