Wago
2004-1306
1 / 3
- Part Number
- 2004-1306
- Tariff Code
- 85369010000
- UPC
- 4045454537487
- ETIM
- Group Code : EG000012
- Group Description : Terminal blocks
- Class Description : Feed-through terminal block
- Class Code : EC000897
- Version : 7
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Ratings Per Iec/En
- Ratings per
- IEC/EN 60947-7-1
- Nominal voltage (III/3)
- 800 V
- Rated impulse voltage (III/3)
- 8 kV
- Rated current
- 32 A
- Current at conductor cross-section (max.) mm²
- 41 A
- Legend (ratings)
- (III / 3) ≙ Overvoltage category III / Pollution degree 3
Environmental Requirements
- Processing temperature
- -35 … +85 °C
- Continuous operating temperature
- -60 … +105 °C
Physical Data
- Width
- 6.2 mm / 0.244 inches
- Height
- 65.5 mm / 2.579 inches
- Depth from upper-edge of DIN-rail
- 32.9 mm / 1.295 inches
Material Data
- Note (material data)
- <a href="https://www.wago.com/us/material-specifications" href="_blank">Information on material specifications can be found here</a>
- Color
- Yellow
- Material group
- I
- Insulation material
- Polyamide (PA66)
- Flammability class per UL94
- V0
- Fire load
- 0.150 MJ
- Weight
- 8.370 g
Mechanical Data
- Mounting type
- DIN-35 rail
- Marking level
- Center/side marking
Specifications
- Product Group Code
- 0022
Commercial Data
- Packaging type
- Box
- Country of origin
- DE
- GTIN
- 4045454537487
- Customs tariff number
- 85369010000
Ex Information
- Reference hazardous areas
- See application instructions in section “Knowledge and Downloads – Documentation – Additional Information: Technical Section; Technical Explications”
- Ratings per
- ATEX: PTB 05 ATEX 1095 U / IECEx: PTB 05.0033U (Ex eb IIC Gb)
- Rated voltage EN (Ex e II)
- 550 V
- Rated current (Ex e II)
- 30 A
Ratings Per Csa
- Approvals per
- CSA 22.2 No 158
- Rated voltage CSA (Use Group B)
- 600 V
- Rated current CSA (Use Group B)
- 30 A
- Rated voltage CSA (Use Group C)
- 600 V
- Rated current CSA (Use Group C)
- 30 A
Power Loss
- Power loss, per pole (potential)
- 1.024 W
- Rated current IN for specified power loss
- 32 A
- Resistance value for specified, current-dependent power loss
- 0.001 Ω
Connection 1
- Connection technology
- Push-in CAGE CLAMP®
- Actuation type
- Operating tool
- Connectable conductor materials
- Copper
- Nominal cross-section
- 4 mm²
- Solid conductor
- 0.5 … 6 mm² / 20 … 10 AWG
- Solid conductor; push-in termination
- 1.5 … 6 mm² / 14 … 10 AWG
- Fine-stranded conductor
- 0.5 … 6 mm² / 20 … 10 AWG
- Fine-stranded conductor; with insulated ferrule
- 0.5 … 4 mm² / 20 … 12 AWG
- Fine-stranded conductor; with ferrule; push-in termination
- 1.5 … 4 mm² / 18 … 12 AWG
- Note (conductor cross-section)
- Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.
- Strip length
- 11 … 13 mm / 0.43 … 0.51 inches
- Wiring direction
- Front-entry wiring
Ratings Per Ul 1059
- Approvals per
- UL 1059
- Rated voltage UL (Use Group B)
- 600 V
- Rated current UL (Use Group B)
- 30 A
- Rated voltage UL (Use Group C)
- 600 V
- Rated current UL (Use Group C)
- 30 A