Weidmuller
2453710000
LUF 10.00/04/90V 5.0SN BK BX
- Erhalten Sie bis zu 90 Tage Zahlungsziele von 500+ Lieferanten
- Wiederverkaufsrabatte bis zu 40%!
Preisanfrage senden
1
Zahlungsmöglichkeiten:
Angebot mit Herstellervorlaufzeit
Lieferung:Auf Anfrage
Bester Preis:
€7.56
Additional Information
- Part Number
- 2453710000
Rated Data Acc. To Ul 1059
- Institute (cURus)
- cURus
- Certificate No. (cURus)
- E60693
- Rated voltage (Use group B / UL 1059)
- 600 V
- Rated voltage (Use group C / UL 1059)
- 600 V
- Rated voltage (Use group D / UL 1059)
- 600 V
- Rated current (Use group B / UL 1059)
- 58 A
- Rated current (Use group C / UL 1059)
- 58 A
- Rated current (Use group D / UL 1059)
- 5 A
- Wire cross-section, AWG, min.
- AWG 18
- Wire cross-section, AWG, max.
- AWG 6
- Reference to approval values
- Specifications are maximum values, details - see approval certificate.
Approvals
- Approvals
- cURus
- ROHS
- Conform
- UL File Number Search
- E60693
Dimensions And Weights
- Width
- 41.58 mm
- Width (inches)
- 1.637 inch
- Height
- 47.03 mm
- Height (inches)
- 1.852 inch
- Height of lowest version
- 42.03 mm
- Depth
- 26.45 mm
- Depth (inches)
- 1.041 inch
- Net weight
- 42.167 g
Rated Data Acc. To Iec
- Tested acc. to standard
- IEC 60947-7-4
- Rated current, min. number of poles (Tu=20°C)
- 76 A
- Rated current, max. number of poles (Tu=20°C)
- 76 A
- Rated current, min. number of poles (Tu=40°C)
- 76 A
- Rated current, max. number of poles (Tu=40°C)
- 76 A
- Rated voltage for surge voltage class / pollution degree II/2
- 1,000 V
- Rated voltage for surge voltage class / pollution degree III/2
- 1,000 V
- Rated voltage for surge voltage class / pollution degree III/3
- 1,000 V
- Rated impulse voltage for surge voltage class/ pollution degree II/2
- 8 kV
- Rated impulse voltage for surge voltage class/ pollution degree III/2
- 8 kV
- Rated impulse voltage for surge voltage class/ contamination degree III/3
- 8 kV
Material Data
- Insulating material
- Wemid (PA)
- Colour
- black
- Colour of operational elements
- orange
- Material of operational elements
- PA4T GF
- Colour chart (similar)
- RAL 9011
- Insulating material group
- I
- Comparative Tracking Index (CTI)
- ≥ 600
- Insulation strength
- ≥ 108 Ω
- UL 94 flammability rating
- V-0
- Contact base material
- E-Cu
- Storage temperature, min.
- -25 °C
- Storage temperature, max.
- 55 °C
- Max. relative humidity during storage
- 80 %
- Operating temperature, min.
- -40 °C
- Operating temperature, max.
- 120 °C
Classifications
- ETIM 6.0
- EC002643
- ETIM 7.0
- EC002643
- EClass 9.0
- 27-44-04-01
- EClass 9.1
- 27-44-04-01
- EClass 10.0
- 27-44-04-01
System Parameters
- Product family
- OMNIMATE Power - series LU
- Wire connection method
- PUSH IN with actuator
- Mounting onto the PCB
- THT solder connection
- Conductor outlet direction
- 90°
- Pitch in mm (P)
- 10 mm
- Pitch in inches (P)
- 0.394 inch
- Number of poles
- 4
- Fitted by customer
- No
- Number of rows
- 1
- Solder pin length (l)
- 5 mm
- Solder pin dimensions
- d = 1.2 mm, Octagonal
- Solder eyelet hole diameter (D)
- 1.6 mm
- Solder eyelet hole diameter tolerance (D)
- + 0,1 mm
- Number of solder pins per pole
- 2
- Screwdriver blade
- 0.8 x 4.0
- Stripping length
- 18 mm
- L1 in mm
- 30 mm
- L1 in inches
- 1.181 inch
- Touch-safe protection acc. to DIN VDE 0470
- IP20 plugged/ IP10 unplugged
- Touch-safe protection acc. to DIN VDE 57 106
- touch-safe with connected connectors from 6 mm²
- Insulation strength
- ≥ 108 Ω
Packing
- Packaging
- Box
- VPE length
- 280 mm
- VPE width
- 170 mm
- VPE height
- 45 mm
Notes
- Notes
- Additional colours on request Rated current related to rated cross-section & min. No. of poles. Wire end ferrule without plastic collar to DIN 46228/1 Wire end ferrule with plastic collar to DIN 46228/4 P on drawing = pitch Rated data refer only to the component itself. Clearance and creepage distances to other components are to be designed in accordance with the relevant application standards. The test point can only be used as potential-pickup point.
- IPC conformity
- Conformity: The products are developed, manufactured and delivered according international recognized standards and norms and comply with the assured properties in the data sheet resp. fulfill decorative properties in accordance with IPC-A-610 "Class 2". Further claims on the products can be evaluated on request.
Conductors Suitable For Connection
- Clamping range, min.
- 0.5 mm²
- Clamping range, max.
- 16 mm²
- Solid, min. H05(07) V-U
- 0.5 mm²
- Solid, max. H05(07) V-U
- 16 mm²
- Stranded, min. H07V-R
- 6 mm²
- Stranded, max. H07V-R
- 16 mm²
- Flexible, min. H05(07) V-K
- 0.5 mm²
- Flexible, max. H05(07) V-K
- 16 mm²
- W. plastic collar ferrule, DIN 46228 pt 4, min.
- 0.5 mm²
- W. plastic collar ferrule, DIN 46228 pt 4, max.
- 16 mm²
- W. wire end ferrule, DIN 46228 pt 1, min.
- 0.5 mm²
- W. wire end ferrule, DIN 46228 pt 1, max.
- 16 mm²
- Plug gauge in accordance with EN 60999 a x b; ø
- 5.3mm (B6)
- Max. clamping range
- 16 mm²
Rated Data Acc. To Csa
- Rated voltage (Use group B / CSA)
- 600 V
- Rated voltage (Use group C / CSA)
- 600 V
- Rated voltage (Use group D / CSA)
- 600 V
- Rated current (Use group B / CSA)
- 58 A
- Rated current (Use group C / CSA)
- 58 A
- Rated current (Use group D / CSA)
- 5 A
- Wire cross-section, AWG, min.
- AWG 18
- Wire cross-section, AWG, max.
- AWG 6