- Air Filter
- washable
- Capacity
- Up to 36,000 Btu
- Capacity
- Up to 36000 BTU
- Controls
- Microprocessor
- Capacity Cooling (BTU/H)
- 31,200 (9,500?31,200)
- Dry Air Flow - High (CFM)
- 1,100
- Dry Air Flow - Low (CFM)
- 750
- Dry Air Flow - Medium (CFM)
- 930
- EER - Cooling
- 8.1
- Elevation Difference - Outdoor Above (ft)
- Max. 100'* This is maximum elevation difference when the indoor unit is located below the outdoor unit."
- Elevation Difference - Outdoor Below (ft)
- Max. 50'* This is maximum elevation difference when the indoor unit is located above the outdoor unit."
- Fan Speeds
- 3 and Automatic Control
- Fuse or Circuit Breaker Capacity (A)
- Indoor Unit - 15 Outdoor Unit - 35
- Grille Assembly
- CZ-24KPU1U
- Capacity Heating (BTU/H)
- 37,400 (8,000?37,400)
- HSPF - Heating
- 8.8
- Indoor Type
- Ceiling Suspended
- Indoor Unit
- S-36PT1U6
- Low Ambient Control
- Built-in 0°F
- Moisture Removal - High (pints/H)
- 10
- Operation Sound - Indoor (Hi/Me/Lo) (dB-A)
- 42 / 40 / 35
- Operation Sound - Outdoor (Hi) (dB-A)
- 52
- Outdoor Unit
- U-36PE1U6
- Power Input - Cooling (W)
- 3,840 / 3,840
- Power Input - Heating (W)
- 3,250 / 3,250
- Power Supply (V, Phase, Hz)
- 230 / 208 / 1 / 60
- Refrigerant
- R-410A
- Refrigerant Control
- Electric Expansion Valve
- Refrigerant Pipe Length (ft)
- Max. 165'
- Refrigerant Piping -Type
- Max. 100'* This is maximum elevation difference when the indoor unit is located below the outdoor unit."
- Running Amps - Cooling (A)
- 18.2 / 20.1
- Running Amps - Heating (A)
- 15.6 / 17.3
- SEER - Cooling
- 15.1
- Series
- Retired Single Zone
- System
- Heating
- System Type
- Heating
- Timer
- 7 Days/6 Events
- Type
- Heating and Cooling
- Unit
- 36PET1U6
- Unit Type
- Indoor Unit. Outdoor Unit
- Wired Remote Controller (optional)
- CZ-RTC2
- Wireless Remote Controller
- CZ-RWSU2U, CZ-RWSC1U (optional)
- Weight
- Indoor Unit - 84Outdoor Unit - 143
Otras categorías
ActuadoresBloquesCables, tuberías y manguerasCompresoresControlAcoplamientos y AccesoriosCilindros y PistonesElectrónicaFiltrosHVACPCs industriales y HMIsIluminaciónTécnica linealMotoresFuente de alimentaciónTransmisión de energíaBombas y VálvulasEnergías renovablesRobóticaSellos, anillos y conectoresSensores y dispositivos de mediciónHerramientas y AccesoriosCNCOtros