Schmersal
103001534
RSS 36-ST-AS-R
- Consigue plazos de pago de hasta 90 días de 500+ proveedores.
- Descuentos de reventa de hasta el 40%!
Enviar solicitud de precio
1
Formas de pago:
Oferta con plazo de entrega del fabricante
Entrega:Bajo pedido
El mejor precio:
Enviar solicitud de precio
Additional Information
- Part Number
- 103001534
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : End switch
- Class Code : EC000030
- Version : 7
Electrical data
- Time to readiness, maximum
- 5,000 ms
- Switching frequency, maximum
- 1 Hz
Electrical data - AS-Interface specification
- AS-i Specification
- Safety-Slave
- AS-i Version
- V 3.0
- AS-i Profile
- S-0.B.F.E
- AS-i, IO-Code
- 0x0
- AS-i, ID-Code
- 0xB
- AS-i, ID-Code1
- 0xF
- AS-i, ID-Code2
- 0xE
- AS-i Input, Channel 1
- Data bits DI 0 / DI 1 = dynamic code transmission
- AS-i Input, Channel 2
- Data bits DI 2 / DI 3 = dynamic code transmission
- AS-i Outputs, DO 0 … DO 3
- No Function
- AS-i Parameter bits, P0
- Actuator in
- AS-i Parameter bits, P1
- Enabling inhibit (tamper protection time) active (FID))
- AS-i Parameter bits, P2
- No function
- AS-i Parameter bits, P3
- Internal device error (FID)
- Note (AS-i Parameter bits)
- Set the parameter outputs to "1111" (0xF) | FID: periphery error
- AS-i Input module address
- 0
- Note (AS-i Input module address)
- Preset to address 0, can be changed through AS-interface bus master or hand-held programming device
Mechanical data - Dimensions
- Length of sensor
- 22 mm
- Width of sensor
- 106.3 mm
- Height of sensor
- 25 mm
Pin assignment
- PIN 1
- AS-Interface +
- PIN 2
- n.c. (≤ 30 VDC)
- PIN 3
- AS-Interface -
- PIN 4
- n.c. (≤ 30 VDC)
Ambient conditions - Insulation values
- Rated insulation voltage U
- 32 VDC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution
- 3
Scope of delivery
- Scope of delivery
- Actuator must be ordered separately.
General data - Features
- Latching
- Yes
- Safety functions
- Yes
- Integral system diagnostics, status
- Yes
- Number of actuating directions
- 3
General data
- Standards
- EN IEC 62026-2 | EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-3 | EN IEC 61508
- Coding
- Universal coding
- Coding level according to EN ISO 14119
- Low
- Working principle
- RFID
- Frequency band RFID
- 125 kHz
- Transmitter output RFID, maximum
- -6 dB/m
- Housing construction form
- Block
- Installation conditions (mechanical)
- not flush
- Enclosure material
- Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Gross weight
- g
- Reaction time, maximum
- 100 ms
- Duration of risk, maximum
- 200 ms
Safety classification
- Standards
- EN ISO 13849-1 | EN IEC 61508
- Performance Level, up to
- e
- Category
- 4
- PFH value
- 5.13 x 10⁻¹⁰ /h
- PFD value
- 3.24 x 10⁻⁵
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission time
- 20 Year(s)
Electrical data - AS Interface
- Rated operating voltage
- 18 ... 31.6 VDC (Protection against polarity reversal)
- AS-i Current consumption, maximum
- 100 mA
Ambient conditions
- Degree of protection
- IP65 | IP67 | IP69
- Ambient temperature
- -25 ... +70 °C
- Storage and transport temperature, minimum
- -25 °C
- Storage and transport temperature, maximum
- +85 °C
- Relative humidity, maximum
- 93 %
- Note (Relative humidity)
- non-condensing | non-icing
- Resistance to vibrations
- 10 … 55 Hz, amplitude 1 mm
- Restistance to shock
- 30 g / 11 ms
- Protection class
- III
- Permissible installation altitude above sea level, maximum
- 2,000 m
Mechanical data - Connection technique
- Termination
- Connector plug M12, 4-pole, (A-coding)
Mechanical data - Switching distances according EN IEC 60947-5-3
- Switch distance, typical
- 12 mm
- Assured switching distance "ON" S
- 10 mm
- Assured switching distance "OFF" S
- 20 mm
Mechanical data
- Mechanical life, minimum
- 1,000,000 Operations
- Note (Mechanical life)
- Actuating speed < 0.25 m/s | Operations for door weights ≤ 5 kg
- Hysteresis (Switching distance), maximum
- 2 mm
- Repeat accuracy R
- 0.5 mm
- Note (Repeat accuracy R)
- Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle).Minimum clearance between two sensor systems 100 mm.
- Latching force, approx.
- 18 N
- Type of the fixing screws
- 2x M4 (cylinder head screws with washers DIN 125A / form A)
- Tightening torque of the fixing screws, minimum
- 2.2 Nm
- Tightening torque of the fixing screws, maximum
- 2.5 Nm
Accessory
- Recommendation (actuator)
- RST 36-1-R
Approvals - Standards
- Certificates
- TÜV | cULus | ASi-SaW
Status indication
- Note (LED switching conditions display)
- (1) green/red LED (AS-i Duo LED):Supply voltage / communication error / slave address = 0 / periphery error detected / Tamper protection time active | (2) yellow LED: device condition (enabling status) / hysteresis signal / device error
Otras categorías
NanómetrosManómetrosFlujómetrosSensoresSensores de aceleraciónSensores de fibra ópticaDetectoresSensores ultrasónicosSensores de temperatura y humedadSensores de vibraciónSensores de nivelSensores de presiónSensores de proximidadSensores InductivosSensores de movimientoGrupo de Sensores MagnéticosSensores ópticosSensores CapacitivosSensores FotoeléctricosSensores de posiciónCodificadoresOtros Sensores y Accesorios