Phoenix Contact
2811873
Temperature measuring transducer - MACX MCR-T-UI-UP-C - 2811873
- Ottenete termini di pagamento fino a 90 giorni da 500+ fornitori.
- Sconti sulla rivendita fino al 40%!
Invia una richiesta di prezzo
1
Metodi di pagamento:
Additional Information
- Part Number
- 2811873
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : Temperature transmitter
- Class Code : EC002919
- Version : 7
Input data
- Sensor types (RTD) that can be used
- Pt, Ni, Cu sensors: 2, 3, 4-wire
- Sensor types that can be used (TC)
- B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
- Temperature measuring range
- -250 °C - 2500 °C (Range depending on the sensor type)
- Input signal range
- 0 Ω - 50 kΩ
- Potentiometer resistance range
- 0 Ω - 50 kΩ
- Input signal range
- -1000 mV - 1000 mV
Note
- Utilization restriction
- EMC: class A product, see manufacturer's declaration in the download area
Dimensions
- Width
- 17.5 mm
- Height
- 112.8 mm
- Depth
- 113.7 mm
Connection data
- Connection method
- Screw connection
- Stripping length
- 7 mm
- Screw thread
- M3
- Conductor cross section solid
- 0.2 mm² - 2.5 mm²
- Conductor cross section flexible
- 0.2 mm² - 2.5 mm²
- Conductor cross section AWG
- 24 - 14
Output data
- Max. voltage output signal
- ± 11 V
- Current output signal
- 4 mA - 20 mA (in the case of SIL; further free configuration without SIL)
- Max. current output signal
- 22 mA
- Load/output load voltage output
- ≥ 10 kΩ
- Load/output load current output
- ≤ 600 Ω (at 20 mA)
- Behavior in the event of a sensor error
- according to NE 43 or freely configurable
- Output name
- Relay output
- Configurable/programmable
- Yes
- Contact type
- 1 PDT
- Contact material
- AgSnO₂, hard gold-plated
- Maximum switching voltage
- 30 V AC (30 V DC)
- Maximum inrush current
- 0.5 A (30 V AC)
- Maximum inrush current
- 1 A (30 V DC)
Ambient conditions
- Ambient temperature (operation)
- -20 °C - 65 °C
- Ambient temperature (storage/transport)
- -40 °C - 85 °C
- Maximum altitude
- ≤ 2000 m
- Permissible humidity (operation)
- typ. 5 % - 95 % (non-condensing)
- Noise immunity
- EN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Environmental Product Compliance
- REACh SVHC
- Lead 7439-92-1
- China RoHS
- Environmentally Friendly Use Period = 50 years
- China RoHS
- For details about hazardous substances go to tab 'Downloads', Category 'Manufacturer's declaration'
Standards and Regulations
- Electromagnetic compatibility
- Conformance with EMC directive
- Noise emission
- EN 61000-6-4
- Electrical isolation
- 4-way, between input/output/power supply/switching output
- Conformance
- CE-compliant
- ATEX
- II 3 G Ex nA nC ic IIC T4 Gc X
- IECEx
- Ex nA nC ic IIC T4 Gc X
- UL, USA/Canada
- UL 508 Listed
- UL, USA/Canada
- Class I, Div. 2, Groups A, B, C, D T6
- UL, USA/Canada
- Class I, Zone 2, Group IIC T6
- DNV GL-Temperature
- B
- DNV GL-Humidity
- B
- DNV GL-Vibration
- A
- DNV GL-EMC
- A
- DNV GL-Enclosure
- Required protection according to the Rules shall be provided upon installation on board
Power supply
- Supply voltage range
- 24 V - 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
- Power consumption
- < 1.5 W
Altre categorie
NanometriManometriFlussimetriSensoriSensori di accelerazioneSensori in fibra otticaRilevatoriSensori ad ultrasuoniSensori di temperatura e umiditàSensori di vibrazioneSensori di livelloSensori di pressioneSensori di prossimitàSensori induttiviSensori di movimentoGruppo di Sensori MagneticiSensori otticiSensori capacitiviSensori FotoelettriciSensori di posizioneEncodersAltri Sensori e Accessori