Phoenix Contact
1412179
Network cable - NBC-MRD SCO RAIL/.../... - 1412179
- Get up to 90 days payment terms from 500+ suppliers
- Reselling discounts up to 40%!
Send request for price
1
Payment methods:
Additional Information
- Part Number
- 1412179
- UPC
- 4046356993777
- ETIM
- Group Code : EG000001
- Group Description : Cables
- Class Description : Data and communication cable (copper)
- Class Code : EC003249
- Version : 7
PROFINET RADOX<sup>®</sup> railway application CAT5 [937]
- Cable type
- PROFINET RADOX® railway application CAT5
- Cable type (abbreviation)
- 937
- Signal type/category
- PROFINET CAT5 (IEC 11801), 100 Mbps
- Signal type/category
- EtherCAT® CAT5 (IEC 11801), 100 Mbps
- Cable structure
- 1x4xAWG22/7; SF/TQ
- Conductor cross section
- 4x 0.34 mm²
- AWG signal line
- 22
- Conductor structure signal line
- 7x 0.25 mm
- Core diameter including insulation
- approx. 1.5 mm
- Wire colors
- white-blue, orange-yellow
- Overall twist
- Star quad
- Shielding
- Plastic-coated aluminum foil, tinned copper braided shield
- External sheath, color
- black RAL 9005
- Outer sheath thickness
- approx. 1 mm
- External cable diameter D
- 6.6 mm ±0.4 mm
- Minimum bending radius, fixed installation
- 6 x D
- Cable weight
- 70 kg/km
- Outer sheath, material
- PE-X
- Material conductor insulation
- Foamed PE
- Conductor material
- silver-plated Cu litz wires
- Conductor resistance
- ≤ 54.4 Ω/km
- Working capacitance
- ≤ 65 pF (core-core)
- Working capacitance
- ≤ 100 pF (core-shield)
- Wave impedance
- 100 Ω ±5 Ω (f = 100 MHz)
- Near end crosstalk attenuation (NEXT)
- 73 dB (with 1 MHz)
- Near end crosstalk attenuation (NEXT)
- 70 dB (at 4 МHz)
- Near end crosstalk attenuation (NEXT)
- 65 dB (at 10 MHz)
- Near end crosstalk attenuation (NEXT)
- 57 dB (at 31.5 МHz)
- Near end crosstalk attenuation (NEXT)
- 52 dB (at 62.5 МHz)
- Near end crosstalk attenuation (NEXT)
- 48 dB (at 100 MHz)
- Remote crosstalk attenuation (FEXT)
- 78 dB (with 1 MHz)
- Remote crosstalk attenuation (FEXT)
- 77 dB (at 4 МHz)
- Remote crosstalk attenuation (FEXT)
- 70 dB (at 10 MHz)
- Remote crosstalk attenuation (FEXT)
- 65 dB (at 31.5 МHz)
- Remote crosstalk attenuation (FEXT)
- 56 dB (at 62.5 МHz)
- Remote crosstalk attenuation (FEXT)
- 48 dB (at 100 MHz)
- Attenuation
- 2 dB (with 1 MHz)
- Attenuation
- 4.4 dB (at 4 МHz)
- Attenuation
- 7.4 dB (at 10 MHz)
- Attenuation
- 14 dB (at 31.5 МHz)
- Attenuation
- 20 dB (at 62.5 МHz)
- Attenuation
- 26 dB (at 100 MHz)
- Return loss (RL)
- 25 dB (at 4 МHz)
- Return loss (RL)
- 30 dB (at 10 MHz)
- Return loss (RL)
- 30 dB (at 31.5 МHz)
- Return loss (RL)
- 30 dB (at 62.5 МHz)
- Return loss (RL)
- 28 dB (at 100 MHz)
- Signal speed
- 75 c
- Shield attenuation
- 40 dB (30 MHz ≤ f ≤ 100 MHz)
- Coupling resistance
- 200.00 mΩ/m (f ≤ 30 MHz)
- Nominal voltage, cable
- 300 V AC
- Test voltage, cable
- 2000 V AC (50 Hz, 5 minutes)
- Fire protection in rail vehicles
- BS 6853 (Category Ia, Ib, II)
- Fire protection in rail vehicles
- GM/RT 2130 (Category Ia, Ib, II)
- Fire protection in rail vehicles
- EN 45545 (Risk level HL1 - HL3)
- Fire protection in rail vehicles
- DIN 5510 (Fire protection level 1, 2, 3, 4)
- Fire protection in rail vehicles
- NF F16-101 (Category A1, A2, B)
- Fire protection in rail vehicles
- NF F16-101 (Class C/F0)
- Fire protection in rail vehicles
- NFPA 130
- Fire protection in rail vehicles
- UNI CEI 11170 (Risk level LR1 - LR4)
- Flame resistance
- EN 60332-1-2
- Flame resistance
- EN 50266
- Flame resistance
- EN 60332-3-25
- Flame resistance
- NF C32-070, 2.1
- Flame resistance
- NF C32-070, 2.2
- Flame resistance
- UL 1685, 12 (FT4)
- Flame resistance
- in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
- Halogen-free
- According to EN 50267-2-1
- Resistance to oil
- according to IRM 902, 72 h at 100 °C
- Other resistance
- Resistance to fuels according to IRM 903, 168 h at 70 °C
- Concentration of fumes
- BS 6853 D.8.7
- Concentration of fumes
- EN 61034-2
- Concentration of fumes
- UL 1685, 12 (FT4)
- Fume corrosiveness
- EN 50267-2-2
- Fume toxicity
- BS 6853 B.1
- Fume toxicity
- EN 50305, 9.2
- Ambient temperature (operation)
- -50 °C - 90 °C (cable, fixed installation)
- Ambient temperature (operation)
- -40 °C - 90 °C (cable, flexible installation)
- Ambient temperature (installation)
- -25 °C - 90 °C
Dimensions
- Length of cable
- Free input (0.2 - 40.0 m)
PROFINET BETAtrans<sup>®</sup> railway application CAT5 [939]
- Cable type
- PROFINET BETAtrans® railway application CAT5
- Cable type (abbreviation)
- 939
- Signal type/category
- PROFINET CAT5 (IEC 11801), 100 Mbps
- Cable structure
- 1x4xAWG22/7; SF/TQ
- Conductor cross section
- 4x 0.34 mm²
- AWG signal line
- 22
- Conductor structure signal line
- 7x 0.25 mm
- Core diameter including insulation
- 1.4 mm ±0.1 mm
- Wire colors
- white-blue, orange-yellow
- Overall twist
- Star quad
- Shielding
- Aluminum-lined polyester foil, tinned copper braided shield
- External sheath, color
- black
- Outer sheath thickness
- 1 mm
- External cable diameter D
- 6.6 mm ±0.2 mm
- Minimum bending radius, fixed installation
- 5 x D
- Minimum bending radius, flexible installation
- 6 x D
- Tensile strength GRP
- ≤ 60 N (temporary)
- Tensile strength GRP
- ≤ 15 N (Permanent)
- Cable weight
- 71 kg/km
- Outer sheath, material
- PE-X
- Material conductor insulation
- Cell PE
- Conductor material
- Tin-plated Cu litz wires
- Insulation resistance
- ≥ 5 GΩ*km
- Conductor resistance
- ≤ 54.4 Ω/km
- Cable capacity
- 44 nF/km (core-core)
- Wave impedance
- 100 Ω ±5 Ω (f = 100 MHz)
- Near end crosstalk attenuation (NEXT)
- 76 dB (with 1 MHz)
- Near end crosstalk attenuation (NEXT)
- 71 dB (at 4 МHz)
- Near end crosstalk attenuation (NEXT)
- 64 dB (at 10 MHz)
- Near end crosstalk attenuation (NEXT)
- 60 dB (at 16 MHz)
- Near end crosstalk attenuation (NEXT)
- 56 dB (at 31.25 МHz)
- Near end crosstalk attenuation (NEXT)
- 52 dB (at 62.5 МHz)
- Near end crosstalk attenuation (NEXT)
- 48 dB (at 100 MHz)
- Near end crosstalk attenuation (NEXT)
- 45 dB (at 155 MHz)
- Near end crosstalk attenuation (NEXT)
- 42 dB (at 200 MHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 73 dB (with 1 MHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 68 dB (at 4 МHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 61 dB (at 10 MHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 57 dB (at 16 MHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 53 dB (at 31.25 МHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 49 dB (at 62.5 МHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 45 dB (at 100 MHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 42 dB (at 155 MHz)
- Power-summated near end crosstalk attenuation (PSNEXT)
- 39 dB (at 200 MHz)
- Attenuation
- 1.5 dB (with 1 MHz)
- Attenuation
- 3.3 dB (at 4 МHz)
- Attenuation
- 5.3 dB (at 10 MHz)
- Attenuation
- 6.9 dB (at 16 MHz)
- Attenuation
- 9.9 dB (at 31.25 МHz)
- Attenuation
- 14.5 dB (at 62.5 МHz)
- Attenuation
- 18.8 dB (at 100 MHz)
- Attenuation
- 23.6 dB (at 155 MHz)
- Attenuation
- 27.3 dB (at 200 MHz)
- Return loss (RL)
- 25 dB (with 1 MHz)
- Return loss (RL)
- 25 dB (at 4 МHz)
- Return loss (RL)
- 28 dB (at 10 MHz)
- Return loss (RL)
- 28 dB (at 16 MHz)
- Return loss (RL)
- 27 dB (at 31.25 МHz)
- Return loss (RL)
- 26 dB (at 62.5 МHz)
- Return loss (RL)
- 25 dB (at 100 MHz)
- Return loss (RL)
- 25 dB (at 155 MHz)
- Return loss (RL)
- 23 dB (at 200 MHz)
- Signal speed
- 0.75 c
- Signal runtime
- 4.4 ns/m
- Shield attenuation
- 60 dB (up to 1000 MHz)
- Coupling resistance
- < 13.00 mΩ/m (f = 1 MHz)
- Coupling resistance
- < 8.00 mΩ/m (f = 10 MHz - 100 MHz)
- Cable impedance
- 100 Ω ±15 Ω (f = 0.5 MHz - 3 MHz)
- Nominal voltage, cable
- 125 V
- Test voltage Core/Core
- 1000 V AC (50 Hz, 1 min.)
- Test voltage Core/Shield
- 1000 V AC (50 Hz, 1 min.)
- Fire protection in rail vehicles
- BS 6853 (Internal cable Ia, Ib, II/external cable Ia, Ib, II)
- Fire protection in rail vehicles
- DIN 5510-2 (Fire protection level 1, 2, 3, 4)
- Fire protection in rail vehicles
- EN 45545-2 (Risk level HL1 - HL3)
- Fire protection in rail vehicles
- EN 50306-4
- Fire protection in rail vehicles
- NF F16-101 (Classification C/F1)
- Fire protection in rail vehicles
- NF F16-101 (Internal cable A1, A2, B/external cable A1, A2, B)
- Fire protection in rail vehicles
- NFPA 130
- Fire protection in rail vehicles
- PN-K-02511
- Fire protection in rail vehicles
- UIC 564-2 (Class A)
- Flame resistance
- according to EN 60332-1-2
- Flame resistance
- according to EN 50266-2-5
- Flame resistance
- according to ISO 14572 5.21 (UN ECE-R 118.01)
- Halogen-free
- According to EN 50267-2-1
- Halogen-free
- according to EN 60684-2
- Resistance to oil
- according to EN 60684-2, 72 h at 100 °C, IRM 902
- Other resistance
- Resistant to fuel according to EN 60684-2, 72 h at 100 °C, IRM 903
- Other resistance
- Resistant to ozone according to EN 50306-4, 72 h at 40 °C, procedure B, volume concentration 200 x 10-⁶
- Concentration of fumes
- EN 61034-2
- Ambient temperature (operation)
- -40 °C - 85 °C (cable, fixed installation)
- Ambient temperature (operation)
- -25 °C - 70 °C (cable, flexible installation)
General data
- Note
- Further products with variable cable type and variable cable length can be found in the accessories section
- Rated current at 40°C
- 4 A
- Rated voltage
- 48 V AC
- Rated voltage
- 60 V DC
- Number of positions
- 4
- Signal type/category
- PROFINET CAT5 (IEC 11801), 100 Mbps
- Signal type/category
- Ethernet CAT5 (IEC 11801), 100 Mbps
- Standards/regulations
- M12 connector IEC 61076-2-101
- Standards/regulations
- Shock, vibration EN 50155
- Overvoltage category
- II
- Degree of pollution
- 3
- Degree of protection
- IP65
Ambient conditions
- Degree of protection
- IP65
- Ambient temperature (operation)
- -40 °C - 85 °C (Plug / socket)
Line characteristics
- Note
- This item is a network cable with a freely selectable cable type. The technical data for all possible cable types is listed in the table below.
PROFINET RADOX<sup>®</sup> railway application CAT5 reinforced [936]
- Cable type
- PROFINET RADOX® railway application CAT5 reinforced
- Cable type (abbreviation)
- 936
- Signal type/category
- PROFINET CAT5 (IEC 11801), 100 Mbps
- Cable structure
- 1x4xAWG22/7; SF/TQ
- Conductor cross section
- 4x 0.34 mm²
- AWG signal line
- 22
- Conductor structure signal line
- 7x 0.25 mm
- Core diameter including insulation
- 1.95 mm
- Wire colors
- white-blue, orange-yellow
- Overall twist
- Star quad
- Shielding
- Plastic-coated aluminum foil, tinned copper braided shield
- Optical shield covering
- 100 %
- External sheath, color
- black RAL 9005
- Outer sheath thickness
- ≥ 0.8 mm
- External cable diameter D
- 7.25 mm ±0.3 mm
- Minimum bending radius, fixed installation
- 6 x D
- Minimum bending radius, flexible installation
- 10 x D
- Cable weight
- 81 g/m
- Outer sheath, material
- PE-X
- Material conductor insulation
- PE-X
- Conductor material
- silver-plated Cu litz wires
- Conductor resistance
- ≤ 54.4 Ω/km
- Working capacitance
- ≤ 65 pF (core-core)
- Working capacitance
- ≤ 100 pF (core-shield)
- Wave impedance
- 100 Ω ±5 Ω (f = 100 MHz)
- Near end crosstalk attenuation (NEXT)
- 80 dB (with 1 MHz)
- Near end crosstalk attenuation (NEXT)
- 76 dB (at 4 МHz)
- Near end crosstalk attenuation (NEXT)
- 67 dB (at 10 MHz)
- Near end crosstalk attenuation (NEXT)
- 60 dB (at 31.5 МHz)
- Near end crosstalk attenuation (NEXT)
- 56 dB (at 62.5 МHz)
- Near end crosstalk attenuation (NEXT)
- 53 dB (at 100 MHz)
- Remote crosstalk attenuation (FEXT)
- 80 dB (with 1 MHz)
- Remote crosstalk attenuation (FEXT)
- 70 dB (at 4 МHz)
- Remote crosstalk attenuation (FEXT)
- 65 dB (at 10 MHz)
- Remote crosstalk attenuation (FEXT)
- 58 dB (at 31.5 МHz)
- Remote crosstalk attenuation (FEXT)
- 59 dB (at 62.5 МHz)
- Remote crosstalk attenuation (FEXT)
- 67 dB (at 100 MHz)
- Attenuation
- 2 dB (with 1 MHz)
- Attenuation
- 4 dB (at 4 МHz)
- Attenuation
- 6.5 dB (at 10 MHz)
- Attenuation
- 10.5 dB (at 31.5 МHz)
- Attenuation
- 14 dB (at 62.5 МHz)
- Attenuation
- 18 dB (at 100 MHz)
- Return loss (RL)
- 35 dB (at 4 МHz)
- Return loss (RL)
- 35 dB (at 10 MHz)
- Return loss (RL)
- 35 dB (at 31.5 МHz)
- Return loss (RL)
- 33 dB (at 62.5 МHz)
- Return loss (RL)
- 33 dB (at 100 MHz)
- Signal speed
- 66 c
- Shield attenuation
- 40 dB (30 MHz ≤ f ≤ 100 MHz)
- Coupling resistance
- 200.00 mΩ/m (f ≤ 30 MHz)
- Nominal voltage, cable
- 300 V AC
- Test voltage, cable
- 2000 V AC (50 Hz, 5 minutes)
- Fire protection in rail vehicles
- BS 6853 (Category Ia, Ib, II)
- Fire protection in rail vehicles
- GM/RT 2130 (Category Ia, Ib, II)
- Fire protection in rail vehicles
- EN 45545 (Risk level HL1 - HL3)
- Fire protection in rail vehicles
- DIN 5510 (Fire protection level 1, 2, 3, 4)
- Fire protection in rail vehicles
- NF F16-101 (Category A1, A2, B)
- Fire protection in rail vehicles
- NF F16-101 (Class C/F0)
- Fire protection in rail vehicles
- NFPA 130
- Fire protection in rail vehicles
- UNI CEI 11170 (Risk level LR1 - LR4)
- Flame resistance
- EN 60332-1-2
- Flame resistance
- EN 50266
- Flame resistance
- EN 60332-3-25
- Flame resistance
- NF C32-070, 2.1
- Flame resistance
- NF C32-070, 2.2
- Flame resistance
- UL 1685, 12 (FT4)
- Flame resistance
- in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
- Halogen-free
- According to EN 50267-2-1
- Resistance to oil
- according to IRM 902, 72 h at 100 °C
- Other resistance
- Resistance to fuels according to IRM 903, 168 h at 70 °C
- Concentration of fumes
- BS 6853 D.8.7
- Concentration of fumes
- EN 61034-2
- Concentration of fumes
- UL 1685, 12 (FT4)
- Fume corrosiveness
- EN 50267-2-2
- Fume toxicity
- BS 6853 B.1
- Fume toxicity
- EN 50305, 9.2
- Ambient temperature (operation)
- -50 °C - 90 °C (cable, fixed installation)
- Ambient temperature (operation)
- -40 °C - 90 °C (cable, flexible installation)
Environmental Product Compliance
- China RoHS
- Environmentally friendly use period: unlimited = EFUP-e
- China RoHS
- No hazardous substances above threshold values
Characteristics head 2
- Head type
- free cable end
- Color
- black
Standards and Regulations
- Standards/specifications
- M12 connector IEC 61076-2-101
- Standards/specifications
- Shock, vibration EN 50155
- Flammability rating according to UL 94
- V0
Characteristics head 1
- Head type
- Plug angled M12 SPEEDCON / IP65
- No. of positions (pin connector pattern)
- 4
- Coding
- D (Data)
- Color
- black
- Material (component)
- CuSn (Contact)
- Material (component)
- Ni/Au (Contact surface)
- Material (component)
- PA 6.6 (Contact carriers)
- Material (component)
- PA 6.6 (Grip)
- Material (component)
- Zinc die-cast, nickel-plated (Screw connection)
- Standards/regulations material
- PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
- Shielded
- yes
- Insulation resistance
- ≥ 100 MΩ
- Insertion/withdrawal cycles
- ≥ 100
- Torque
- 0.4 Nm
- Ambient temperature (operation)
- -40 °C - 85 °C
- Type type, plug side
- Plug angled
- Type type, socket side
- free cable end