3NW1015-0HG
SENTRON, cylindrical fuse link, Class CC, 1,5 A, slow, Un AC: 600 V
SENTRON, cylindrical fuse link, Class CC, 1,5 A, slow, Un AC: 600 V
- Nowy1 szt.
Filtry
SENTRON, cylindrical fuse link, Class CC, 1,5 A, slow, Un AC: 600 V
SENTRON, cylindrical fuse link, Class CC, 1,5 A, slow, Un AC: 600 V
CYLINDRICAL FUSE LINK,SZ10X38MM,500V,16A SIZE 10X38MM, 500V 16A WITHOUT INDICATOR ACC. TO FRENCH STANDARD (NFC) CYLINDRICAL FUSE GG
CYLINDRICAL FUSE LINK,SZ10X38MM,500V,16A SIZE 10X38MM, 500V 16A WITHOUT INDICATOR ACC. TO FRENCH STANDARD (NFC) CYLINDRICAL FUSE GG
Fuse, number: 10 Pcs., fuse type: Fuse (CC), nominal current: 16 A, tripping characteristic: super-fast blow (gR)
Fuse, number: 10 Pcs., fuse type: Fuse (CC), nominal current: 16 A, tripping characteristic: super-fast blow (gR)
FUSE LINK,LV HRC,100A,500VAC,250VDC SIZE 00, 100A, 500V W. NON-INSULATED GRIPPING LUGS LV HRC FUSE LINK GL/GG
FUSE LINK,LV HRC,100A,500VAC,250VDC SIZE 00, 100A, 500V W. NON-INSULATED GRIPPING LUGS LV HRC FUSE LINK GL/GG
Switch Fuses,Front Operated,3-pole,12 (Between the Poles),DIN,0,1,Handle and shaft included,
Switch Fuses,Front Operated,3-pole,12 (Between the Poles),DIN,0,1,Handle and shaft included,
CYLINDRICAL FUSE 10X38MM,500V,4A SIZE 10X38MM, 500V 4A WITHOUT INDICATOR ACC. TO FRENCH STANDARD (NFC) CYLINDRICAL FUSE GG
CYLINDRICAL FUSE 10X38MM,500V,4A SIZE 10X38MM, 500V 4A WITHOUT INDICATOR ACC. TO FRENCH STANDARD (NFC) CYLINDRICAL FUSE GG
SITOR FUSE LINKS 63A, AC 690V SITOR FUSE LINKS 63A, AC 690V (DIN 43620, SIZE 00)
SITOR FUSE LINKS 63A, AC 690V SITOR FUSE LINKS 63A, AC 690V (DIN 43620, SIZE 00)
CYL FUSE,10A,10 X 38 SIZE 10X38MM, 500V 10A WITHOUT INDICATOR ACC. TO FRENCH STANDARD (NFC) CYLINDRICAL FUSE GG
CYL FUSE,10A,10 X 38 SIZE 10X38MM, 500V 10A WITHOUT INDICATOR ACC. TO FRENCH STANDARD (NFC) CYLINDRICAL FUSE GG
This is a DIN fuse cartridge for TeSys GS switch-disconnector fuses devices. It is a aM fuse-link that protects against magnetic over currents only, adapted for motor protection. Its current rating is 160 A and the maximum rated voltage is 690 VAC. It is a blade size 1 DIN cartridge fuse. It has no striker to indicate when the fuse is blown. This fuse is sold by set of 3 parts.
This is a DIN fuse cartridge for TeSys GS switch-disconnector fuses devices. It is a aM fuse-link that protects against magnetic over currents only, adapted for motor protection. Its current rating is 160 A and the maximum rated voltage is 690 VAC. It is a blade size 1 DIN cartridge fuse. It has no striker to indicate when the fuse is blown. This fuse is sold by set of 3 parts.
SENTRON, cylindrical fuse link, Class CC, 6 A, quick, Un AC: 600 V
SENTRON, cylindrical fuse link, Class CC, 6 A, quick, Un AC: 600 V
SENTRON, cylindrical fuse link, Class CC, 5 A, slow, current limiting, Un AC: 600 V
SENTRON, cylindrical fuse link, Class CC, 5 A, slow, current limiting, Un AC: 600 V
Mersen aM and gG fuse-links cover a wide range of physical sizes and ampere ratings for 400, 500, and 690VAC for protection in electrical distribution circuits and various industrial applications. Most ratings are available in size 8x31 and size 10x38 with an optional indicator, and in size 14x51 and 22x58 with an optional striker to activate an auxiliary contact. All cylindrical fuse-links have ceramic bodies and silver-plated ferrules. Cylindrical fuse-links gG are used for the protection of cables, motors and LV-networks. They limit and cut off unacceptable overcurrents and short-circuit currents up to their nominal breaking capacity. Cylindrical fuse-links gG also protect electrical equipment and installations against the dynamic effect of high short-currents. Our technology and process was designed to ensure highly reliable technical performance.
Mersen aM and gG fuse-links cover a wide range of physical sizes and ampere ratings for 400, 500, and 690VAC for protection in electrical distribution circuits and various industrial applications. Most ratings are available in size 8x31 and size 10x38 with an optional indicator, and in size 14x51 and 22x58 with an optional striker to activate an auxiliary contact. All cylindrical fuse-links have ceramic bodies and silver-plated ferrules. Cylindrical fuse-links gG are used for the protection of cables, motors and LV-networks. They limit and cut off unacceptable overcurrents and short-circuit currents up to their nominal breaking capacity. Cylindrical fuse-links gG also protect electrical equipment and installations against the dynamic effect of high short-currents. Our technology and process was designed to ensure highly reliable technical performance.
Mersen aM and gG fuse-links cover a wide range of physical sizes and ampere ratings for 400, 500, and 690VAC for protection in electrical distribution circuits and various industrial applications. Most ratings are available in size 8x31 and size 10x38 with an optional indicator, and in size 14x51 and 22x58 with an optional striker to activate an auxiliary contact. All cylindrical fuse-links have ceramic bodies and silver-plated ferrules. Cylindrical fuse-links aM are partial range fuses. They protect electrical devices in case of unacceptable high short-circuit against destruction due high current limiting and low thermal let-through values. They cut off currents more than 6.3xln until the maximum breaking capacity (rated breaking capacity). Cylindrical fuse-links aM are mainly used for the protection of installation switch gear in otor circuit currents. For classification of the cylindrical fuse-links the nominal current of the fuse-link can be selected respective to the nominal current of the motor. Our technology and process was designed to ensure highly reliable technical performance.
Mersen aM and gG fuse-links cover a wide range of physical sizes and ampere ratings for 400, 500, and 690VAC for protection in electrical distribution circuits and various industrial applications. Most ratings are available in size 8x31 and size 10x38 with an optional indicator, and in size 14x51 and 22x58 with an optional striker to activate an auxiliary contact. All cylindrical fuse-links have ceramic bodies and silver-plated ferrules. Cylindrical fuse-links aM are partial range fuses. They protect electrical devices in case of unacceptable high short-circuit against destruction due high current limiting and low thermal let-through values. They cut off currents more than 6.3xln until the maximum breaking capacity (rated breaking capacity). Cylindrical fuse-links aM are mainly used for the protection of installation switch gear in otor circuit currents. For classification of the cylindrical fuse-links the nominal current of the fuse-link can be selected respective to the nominal current of the motor. Our technology and process was designed to ensure highly reliable technical performance.
The NH system is classified among plug-in fuse systems and is composed of: fuse-base (possibly including terminal covers and phase barriers) fuse-link with blade contact fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type aM NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.
The NH system is classified among plug-in fuse systems and is composed of: fuse-base (possibly including terminal covers and phase barriers) fuse-link with blade contact fuse-link replacement device (LV HRC fuse puller) Since the design of this system cannot guarantee non-interchangeability of rated current it must be handled by a qualified professional. Type aM NH fuse-links are partial-range breaking capacity fuse-links, used to protect motor circuits as they are strongly current-limiting and have low power losses. They interrupt currents from 6.3 times In up to their maximum breaking capacity and are therefore suited for short-circuit protection only. They must be associated with other switchgear for protection against overloads. These fuse-links can have a rated current equal to the motor's nominal current.
Fuse, 10.3x38 mm, up to 1000 V DC, gPV characteristics
Fuse, 10.3x38 mm, up to 1000 V DC, gPV characteristics
FUSE LINK, SITOR, 6A, 600V AC,10 X 38MM SITOR CYLINDRICAL FUSE LINK AR 6 A, 600 V AC/400V DC
FUSE LINK, SITOR, 6A, 600V AC,10 X 38MM SITOR CYLINDRICAL FUSE LINK AR 6 A, 600 V AC/400V DC