CM-IWN.5S Insulation monitoring relay 2c/o, 1-100kOhm,2-200kOhm, 24-240VAC/DC
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Additional Information
- Part Number
- 1SVR750660R0400
- ETIM
- Group Code : EG000019
- Group Description : Relays
- Class Description : Insulation and earth fault monitoring relay
- Class Code : EC001444
- Version : 7
Dimensions
- Product Net Width
- 45 mm
- Product Net Height
- 85.6 mm
- Product Net Depth / Length
- 104.8 mm
- Product Net Weight
- 0.241 kg
Technical
- Function
- Unearthed AC systemsUnearthed DC systemsUnearthed mixed AC / DC systemsUp to 400 V ACUp to 600 V DC
- Measuring Range
- 1 ... 200 kΩ
- Rated Control Supply Voltage (Us)
- 24 ... 240 V AC/DC
- Output
- 2 x 1 c/o or 1 x 2 c/o contacts, configurable
- Terminal Type
- Screw Terminals
- Rated Operational Current AC-12 (Ie)
- (230 V) 4 A
- Rated Operational Current AC-15 (Ie)
- (230 V) 3 A
- Rated Operational Current DC-12 (Ie)
- (24 V) 4 A
- Rated Operational Current DC-13 (Ie)
- (24 V) 2 A
- Minimum Switching Capacity
- 24 V10 mA
- Rated Impulse Withstand Voltage (Uimp)
- Measuring Circuit / Output Circuit 6 kVOutput Circuit 1 / Output Circuit 2 4 kVSupply Circuit / Measuring Circuit 6 kVSupply Circuit / Output Circuit 6 kV
- Rated Insulation Voltage (Ui)
- Measuring Circuit / Output Circuit 600 VOutput Circuit 1 / Output Circuit 2 300 VSupply Circuit / Measuring Circuit 600 VSupply Circuit / Output Circuit 300 V
- Degree of Protection
- Housing IP50Terminals IP20
- Overvoltage Category
- III
- Pollution Degree
- 3
- Short-Circuit Protective Devices
- Output Circuit NC - F Type Fuses 6 AOutput Circuit NO - F Type Fuses 10 A
- System Leakage Capacitance (CE)
- 1000 µF
- Electrical Durability
- AC-12 100000 cycle
- Mechanical Durability
- 30000000 cycle
- Connecting Capacity
- Flexible with Ferrule 1x 0.5 ... 2.5 mm²Flexible with Ferrule 2x 0.5 ... 1.5 mm²Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²Flexible 1x 0.5 ... 2.5 mm²Flexible 2x 0.5 ... 1.5 mm²Rigid 1x 0.5 ... 4 mm²Rigid 2x 0.5 ... 2.5 mm²
- Tightening Torque
- 0.6 ... 0.8 N·m
- Wire Stripping Length
- 8 mm
- Mounting Position
- 1 ... 6
- Mounting on DIN Rail
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- Standards
- CAN/CSA C22.2 No.14IEC/EN 63000IEC/EN 60947-5-1UL 508
Classifications
- Object Classification Code
- B
- ETIM 9
- EC001444 - Insulation and earth fault monitoring relay
- EClass
- V11.0 : 27371807
Environmental
- Ambient Air Temperature
- Operation -25 ... +60 °CStorage -40 ... +85 °C
- RoHS Status
- Following EU Directive 2011/65/EU
Technical UL/CSA
- Maximum Operating Voltage UL/CSA
- Output Circuit 300 V AC
- Contact Rating UL/CSA
- B300
- Connecting Capacity UL/CSA
- Flexible 1x 18-14 AWGFlexible 2x 18-16 AWGRigid 1x 20-12 AWGRigid 2x 20-14 AWG
- Tightening Torque UL/CSA
- 7.08 in·lb
- Pilot Duty UL/CSA
- B300
Ordering
- Minimum Order Quantity
- 1 piece
- Customs Tariff Number
- 85364900