General Specifications
- Channel capacity
- Analog inputs: 22 channels; 8 digital I/O and 6 alarm outputs (TTL)
- Channel capacity Totalizer
- 1
- Power
- Voltage: 100 V to 264 A in 4 power model selections (100 V, 120 V, 220 V, 240 V)
- Power Frequency
- 47 Hz to 440 Hz (automatically sensed when turned on)
- Power Power consumption
- 34 V A peak (24 W average)
- Communication LAN
- 10/100 Mb TCPIP DHCP
- Communication
- Remote commands: SCPI command set
- Internal memory
- 57,000 scans 1000 setup files
- File security
- Dual level, Administrator, five secure users, Guest status
- Alarm outputs
- 6 TTL alarm outputs -- assignable to one or multiple channels
- Alarm setpoints
- 2 assignable setpoints/channel, Hi Lo, Hi Hi, Lo Lo
- Language menus
- English, Chinese, French, German, Japanese, Korean, Portuguese, Russian, Spanish
- Temperature
- Operating: 0°C to 50°C
- Temperature Storage
- 20°C to 70°C
- Temperature Warm-up
- One hour to full uncertainty specifications
- Relative humidity (non-condensing)
- Operating: 0°C to 28°C < 90%, 28°C to 40°C < 75%, 40°C to 50°C < 50%
- Relative humidity (non-condensing) Storage
- 20°C to 70°C <95%
- Relative humidity (non-condensing) Weight
- 6 kg (13.2 lbs)
- Dimensions
- 150 x 285 x 385 mm (5.91 x 11.22 x 15.16 in)
- Standard rack height
- 3 U
Technical Specifications
- DC volts Range
- 100 MV to 300 V
- DC volts Resolution
- 0.1 µV to 1 mV
- DC volts Accuracy
- 0.0024%
- AC volts Range
- 100 MV to 300 V
- AC volts Resolution
- 0.1 µV to 1 mV
- AC volts Accuracy
- 0.11%
- Resistance Range
- 100 Ω to 100 MΩV
- Resistance Resolution
- 0.1 mΩ to 100 Ω
- Resistance Accuracy
- 0.01%
- Frequency Range
- 20 Hz to 1 MHz
- Frequency Accuracy
- 0.01%
- RTD (Pt 100) Range
- -200°C
- RTD (Pt 100) Resolution
- 0.001°C
- RTD (Pt 100) Accuracy
- 0.016°C
- J thermocouples Range
- -200°C to 1,000°C
- J thermocouples Resolution
- 0.01°C
- J thermocouples Accuracy
- 0.53°C
- K thermocouples Range
- -200°C to 1,000°C
- K thermocouples Resolution
- 0.01°C
- K thermocouples Accuracy
- 0.60°C
- T thermocouples Range
- -270°C to 400°C
- T thermocouples Resolution
- 0.01°C
- T thermocouples Accuracy
- 0.62°C
- Other thermocouple types
- R, S, N, E, B, C, D, G, L, M, U, W
Dokumenty
Data Sheet
PobierzInne kategorie
AktuatoryBlokiPrzewody, rury i wężeSprężarkiKontrolaŁączniki i złączkiCylindry i tłokiElektronikaFiltracjaHVACKomputery przemysłowe i interfejsy HMIOświetlenieTechnika liniowaSilnikiZasilaczPrzekazywanie mocyPompy i zaworyEnergia odnawialnaRobotykaUszczelki, pierścienie i złączkiCzujniki i urządzenia pomiaroweNarzędzia i akcesoriaCNCInne