Honeywell
Y8610U6006/U
Converts atmospheric standing pilot gas systems to intermittent pilot. Max capacity of 270kBtuh
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Specifications
- Dimensions (in.)
- 3 15/16 in. high x 5 7/16 in. wide x 2 5/8 in. deep
- Dimensions (mm)
- 100 mm high x 138 mm wide x 67 mm deep
- Includes
- VR8304M3558 (1/2 x 3/4; 3.5" setting; 270kBtu/hr at 1 in. p.d.)
- Item Type
- Product
- Electrical Ratings
- 24 Vac
- Frequency
- 60 Hz
- Flame Failure Response Time (sec)
- 2.0 sec
- PrePurge
- 0 or 30 seconds
- Ambient Temperature Range (F)
- -40 F to +165 F
- Ambient Temperature Range (C)
- -40 C to +74 C
- Ignition System Type
- Intermittent Pilot
- Ignition Sequence
- Continuous retry, after trial for ignition, pilot gas shuts off for 5 minutes, then another trial for pilot ignition takes place
- Typical Gas Control
- VR8204, VR8304
- Type of Gas
- Natural or LP
- Flame Sense
- Single Rod or Two Rods
- Ignition Source
- Internal high voltage spark generator
- Ignition Trials To Lockout
- continuous retry
- Lockout Timing
- 15 or 90 seconds
- Ignition Trial Time (sec)
- 15 or 90 seconds
- Maximum Valve Load @ 24 Vac (Amps)
- 1A Pilot, 2A Main @ 24Vac
- Typical Ignition Hardware
- Q345, Q3451
Dokumenty
Data Sheet
PobierzInne kategorie
AktuatoryBlokiPrzewody, rury i wężeSprężarkiKontrolaŁączniki i złączkiCylindry i tłokiElektronikaFiltracjaHVACKomputery przemysłowe i interfejsy HMIOświetlenieTechnika liniowaSilnikiZasilaczPrzekazywanie mocyPompy i zaworyEnergia odnawialnaRobotykaUszczelki, pierścienie i złączkiCzujniki i urządzenia pomiaroweNarzędzia i akcesoriaCNCInne