Prosoft

MVI56E-MCM

1 / 3
thumbnail
thumbnail
thumbnail

Opis

The MVI56E Communication Module allows for Modbus Master and/or Slave connectivity from Rockwell Automation® ControlLogix® processors to Modbus RTU/ASCII devices. Each MVI56E port can be configured as a Master or Slave. The MVI56E-MCM and MVI56E-MCMXT act as input/output modules on the ControlLogix backplane, making Modbus data appear as I/O data to the processor. Two independently configurable serial ports can operate on the same or different Modbus networks. The MVI56E-MCM is designed for standard process applications and the MVI56E-MCMXT is designed for the Logix-XT™ control platform, allowing it to operate in extreme environments. It can tolerate higher operating temperatures, and has conformal coating to protect it from harsh or caustic conditions.
Part Number
MVI56E-MCM
Metody płatności:
Najlepsza oferta od:
GBZaufany dostawca Automa.Net
Dostępność:
2 szt.
W magazynie
Zaktualizowano: 30-04-2024
Szacowany czas dostawy:
Na zapytanie
Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Fabrycznie Nowe, Zapieczętowane - Nowy, nieużywany, nieotwarty, nieuszkodzony przedmiot w oryginalnym opakowaniu zapieczętowanym przez producenta.
Łącznie 5 części w magazynie od 2 dostawców
Bezpieczny proces płatności
Zasady zwrotów i reklamacji
Zasady wysyłki
Gwarancja

Dostępne Oferty (2)

MVI56E-MCM product image
Prosoft

MVI56E-MCM

Stan produktu:
Nowy, Rynek wtórny
Dostępność:
2 szt.
W magazynie
Zaktualizowano: 21-10-2024
Oferta od:
GBZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
MVI56E-MCM product image
Prosoft

MVI56E-MCM

Stan produktu:
Nowy, Rynek wtórny
Dostępność:
1 szt.
W magazynie
Zaktualizowano: 21-10-2024
Oferta od:
GBZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1

Specifications

Protocol
Modbus Master/Slave
Platform
ControlLogix
Mounting Method
Chassis

Modbus Master Specifications

Command List
Up to 325 commands per Master port, each fully configurable for function code, slave address, register to/from addressing and word/bit count.
Optimized Polling
Configuration options allow Master ports and commands to be optimized to poll slaves with communication problems less frequently.
Command Status/Error Monitoring
Command Status or Error codes are generated for each command as it executes, allowing careful monitoring o fcommunication health between the Master and its Slaves.
Slave Polling Control
Master Port maintains a Slave Status list of all network Slaves. Polling of each Slave may be disabled and enabled using this list.

Modbus Slave Specifications

Full Memory Access
A port configured as a Modbus Slave permits a remote Master to read from or write to any of the 5000 registers that make up the user memory database.
Multi-source Slave data
Data presented at the Slave port can be derived from other Modbus Slave devices on a different network through the module's Master port or from the processor tag database.
Node address
1 to 247 (software selectable)
Status Data
Slave port error codes, counters and statuses are available separately for each port when configured as a Slave