Schmersal
103032138
AZM201Z-I2-CC-T-SD2P
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Oferta z czasem realizacji przez producenta
Wysyłka:Na zapytanie
Najlepsza cena:
Wyślij zapytanie o cenę
Additional Information
- Part Number
- 103032138
- ETIM
- Group Code : EG000026
- Group Description : Sensors
- Class Description : Position switch with guard locking
- Class Code : EC002593
- Version : 7
Electrical data - Safety digital inputs
- Designation, Safety inputs
- X1 and X2
- Switching thresholds
- −3 V … 5 V (Low) | 15 V … 30 V (High)
- Current consumption at 24 V
- 5 mA
- Test pulse duration, maximum
- 1 ms
- Test pulse interval, minimum
- 100 ms
- Classification ZVEI CB24I, Sink
- C1
- Classification ZVEI CB24I, Source
- C1 | C2 | C3
Electrical data - Serial diagnostic SD
- Designation, Serial diagnostic SD
- OUT
- Operation current
- 150 mA
- Design of control elements
- short-circuit proof, p-type
- Wiring capacitance
- 50 nF
Electrical data
- Operating voltage
- 24 VDC -15 % / +10 % (stabilised PELV power supply)
- No-load supply current I
- 50 mA
- Current consumption with magnet ON, average
- 200 mA
- Current consumption with magnet ON, peak
- 700 mA / 100 ms
- Rated operating voltage
- 24 VDC
- Operating current
- 1,200 mA
- Required rated short-circuit current
- 100 A
- External wire and device fuse rating
- 4 A gG
- Time to readiness, maximum
- 4,000 ms
- Switching frequency, maximum
- 1 Hz
Note
- Note (General)
- As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened.
Mechanical data - Dimensions
- Length of sensor
- 50 mm
- Width of sensor
- 40 mm
- Height of sensor
- 220 mm
Ambient conditions - Insulation values
- Rated insulation voltage U
- 32 VDC
- Rated impulse withstand voltage U
- 0.8 kV
- Overvoltage category
- III
- Degree of pollution
- 3
Scope of delivery
- Scope of delivery
- Actuator must be ordered separately. | Triangular key for AZM 201
Electrical data - Magnet control
- Designation, Magnet control
- IN
- Switching thresholds
- -3 V … 5 V (Low) | 15 V … 30 V (High)
- Magnet switch-on time
- 100 %
- Test pulse duration, maximum
- 5 ms
- Test pulse interval, minimum
- 40 ms
- Classification ZVEI CB24I, Sink
- C0
- Classification ZVEI CB24I, Source
- C1 | C2 | C3
General data - Features
- Power to unlock
- Yes
- Solenoid interlock monitored
- Yes
- Serial diagnostics
- Yes
- Manual release
- Yes
- Short circuit detection
- Yes
- Cross-circuit detection
- Yes
- Series-wiring
- Yes
- Safety functions
- Yes
- Integral system diagnostics, status
- Yes
- Number of safety contacts
- 2
- Number of series-wiring of sensors
- 31
General data
- Standards
- EN ISO 13849-1 | EN ISO 14119 | EN IEC 60947-5-3 | EN IEC 61508
- Coding
- Individual coding, multiple teaching
- Coding level according to EN ISO 14119
- High
- Working principle
- RFID
- Frequency band RFID
- 125 kHz
- Transmitter output RFID, maximum
- -6 dB/m
- Enclosure material
- Glass-fibre, reinforced thermoplastic
- Gross weight
- 576 g
- Duration of risk, maximum
- 200 ms
- Reaction time, switching off safety outputs via actuator, maximum
- 100 ms
- Reaction time, switching off safety outputs via safety inputs, maximum
- 1.5 ms
Safety classification
- Standards
- EN ISO 13849-1 | EN IEC 61508
Electrical data - Safety digital outputs
- Designation, Safety outputs
- Y1 and Y2
- Rated operating current (safety outputs)
- 250 mA
- Design of control elements
- short-circuit proof, p-type
- Voltage drop U
- 2 V
- Current at Voltage drop U
- 2 A
- Leakage current I
- 0.5 mA
- Voltage, Utilisation category DC-13
- 24 VDC
- Current, Utilisation category DC-13
- 0.25 A
- Test pulse interval, typical
- 1000 ms
- Test pulse duration, maximum
- 0.5 ms
- Classification ZVEI CB24I, Source
- C2
- Classification ZVEI CB24I, Sink
- C1 | C2
Safety classification - Interlocking function
- Performance Level, up to
- e
- Category
- 4
- PFH value
- 1.90 x 10⁻⁹ /h
- PFD value
- 1.60 x 10⁻⁴
- Safety Integrity Level (SIL), suitable for applications in
- 3
- Mission time
- 20 Year(s)
Ambient conditions
- Degree of protection
- IP67 | IP66
- Ambient temperature
- -25 ... +60 °C
- Storage and transport temperature, minimum
- -25 °C
- Storage and transport temperature, maximum
- +85 °C
- Relative humidity, maximum
- 93 %
- Note (Relative humidity)
- non-condensing | non-icing
- Resistance to vibrations
- 10 … 150 Hz, amplitude 0.35 mm
- Restistance to shock
- 30 g / 11 ms
- Protection class
- III
- Permissible installation altitude above sea level, maximum
- 2,000 m
Mechanical data - Connection technique
- Termination
- Spring pulley connection
- Length of sensor chain, maximum
- 200 m
- Note (length of the sensor chain)
- Cable length and cross-section change the voltage drop dependiing on the output current
- Note (series-wiring)
- Unlimited number of devices, oberserve external line fusing, max. 31 devices in case of serial diagnostic SD
- Cable entry
- 1x M20
- Cable section, minimum
- 0.25 mm²
- Cable section, maximum
- 1.5 mm²
- Note (Cable section)
- All indications including the conductor ferrules.
- Wire cross-section, minimum
- 23 AWG
- Wire cross-section, maximum
- 15 AWG
- Wire cross-section
- 23 ... 15 AWG
- Allowed type of cable
- solid single-wire | solid multi-wire | flexible
Mechanical data
- Mechanical life, minimum
- 1,000,000 Operations
- Holding force F
- 2,000 N
- Note (clamping force F
- 1,000 N when used with the AZ/AZM201-B30 actuator, for indoor use.
- Holding force F
- 2,600 N
- Note (clamping force F
- 1,300 N when used with the AZ/AZM201-B30 actuator, for indoor use.
- Latching force
- 30 N
- Actuating speed, maximum
- 0.2 m/s
- Type of the fixing screws
- 2x M6
- Tightening torque of the fixing screws, maximum
- 8 Nm
- Tightening torque of the fastening screws for the housing cover, minimum
- 0.7 Nm
- Tightening torque of the fastening screws for the housing cover, maximum
- 1 Nm
- Note
- Torx T10
Accessory
- Recommendation (actuator)
- AZ/AZM201-B1 | AZ/AZM201-B30
Approvals - Standards
- Certificates
- TÜV | cULus | FCC | IC
Status indication
- Note (LED switching conditions display)
- Operating condition: LED green | Error / functional defect: LED red | Supply voltage UB: LED green
Modele CAD
Części śladowe
PobierzInne kategorie
NanometryManometryPrzepływomierzeCzujnikiCzujniki przyspieszeniaCzujniki światłowodoweDetektoryCzujniki ultradźwiękoweCzujniki temperatury i wilgotnościCzujniki wibracjiCzujniki poziomuCzujniki ciśnieniaCzujniki zbliżenioweCzujniki indukcyjneCzujniki ruchuGrupa Czujników MagnetycznychCzujniki optyczneCzujniki pojemnościoweCzujniki fotoelektryczneCzujniki położeniaEnkoderyInne czujniki i akcesoria