Type S non-reversing magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is provided separately. Type S contactors have ratings up to 810 amperes. This 2 pole NEMA Size 00 non-reversing contactor has a 9 ampere rating. Single phase NEMA Size 00 contactors have 0.33 HP at 115 VAC and 1 HP at 230 VAC ratings. This NEMA contactor has a 100 kA maximum SCCR rating per UL508A when protected by an appropriate circuit breaker or fuse. These contactors are available with replaceable coils in a wide variety of voltages. This contactor has a 220/240 VAC 50/60 Hz coil that is wired for common control. This NEMA contactor is an open device without an enclosure. This contactor is 4.34 inches tall, 3.22 inches wide and 4.22 inches deep. A wide variety of accessories are available for Type S contactors. Type S NEMA contactors are UL listed and CSA certified.- Country of Origin
- MX
- Part Number
- 8502SAO11V03
- EAN
- 39121529
- UPC
- 785901237556
- UNSPSC
- 39121529
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Specifications
- Range Of Product
- 8502S
- Contactor Application
- non-reversing
- Product Or Component Type
- contactor
Contractual warranty
- Warranty
- 18 months
Environmental
- Product Certifications
- UL listed file E78351 CCN NLDX || CSA
- Nema Degree Of Protection
- not rated (open device)
Complementary
- Local Signalling
- no indicator
- Height
- 110.24 mm
- Auxiliary Contact Composition
- without
- Nema Size
- 00
- [Uc] Control Circuit Voltage
- 240 V AC 60 Hz || 220 V AC 50 Hz
- Poles Description
- 2P
- Rated Power In Hp
- 0.33 HP 115 V AC || 1 HP 230 V AC
- Electrical Connection
- screw clamp terminals
- Provided Equipment
- fuse not supplied
- Product Compatibility
- circuit-breaker 70 A maximum, SCCR: 100 kA at 480 V AC || fuse J 60 A maximum, SCCR: 100 kA at 600 V AC || fuse T 60 A maximum, SCCR: 100 kA at 600 V AC || fuse RK1 60 A maximum, SCCR: 100 kA at 600 V AC || fuse RK5 60 A maximum, SCCR: 100 kA at 600 V AC
- Line Rated Current
- 9 A
- Control Type
- no control units
- Control Circuit
- common control circuit
- Width
- 81.79 mm
- Depth
- 107.19 mm
- Phase
- 1 phase
- [Ue] Rated Operational Voltage
- 600 V AC
Offer Sustainability
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Eu Rohs Directive
- Not compliant
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
Dokumenty
Data Sheet
PobierzInne kategorie
SiłownikiBlokiKable, rury i wężeSprężarkiSterowanieŁączniki i osprzętCylindry i tłokiElektronikaFiltryHVACKomputery przemysłowe i interfejsy HMIOświetlenieTechnika liniowaSilnikiZasilaniePrzeniesienie napęduPompy i zaworyEnergia odnawialnaRobotykaUszczelki, pierścienie i złączaCzujniki i urządzenia pomiaroweNarzędzia i akcesoriaCNCInne