Schneider Electric
9007TUB5
1 / 1
Opis
Końcówka Serii
9007T severe duty mill switches are designed for applications requiring extra heavy duty contact ratings, or higher operating and reset forces. Limit switch has rugged mechanical construction with several different operating sequences in one basic switch. This rotary lever arm limit switch has one normally closed and one normally open contact. This spring return switch only operates in the counter clockwise direction. Contacts have an A600 and a P600 inductive rating and 20A resistive rating. Limit switch is NEMA 1, 2, 4, 12 and 13 rated. It is also IP65, IP66 and IP67 rated. Limit switch is UL Listed and CSA certified. The 9007 T/FT mill and foundry for severe duty applications, convertible sequences, 59mm housing, including spring return, maintained and neutral position versions. The 9007 series limit switches are designed to withstand harsh industrial environments and are available in a wide range of options.- Country of Origin
- MX
- Part Number
- 9007TUB5
- Tariff Code
- 8536509055
- EAN
- 39122213
- UPC
- 785901752004
- UNSPSC
- 39122213
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Specifications
- Range Of Product
- 9007
- Product Or Component Type
- limit switch
- Head Type
- rotary head
- Series Name
- severe duty mill
- Sale Per Indivisible Quantity
- 1
- Body Type
- fixed
- Device Application
- universal mill switch
- Device Short Name
- 9007T/FT
Contractual warranty
- Warranty
- 18 months
Complementary
- Maximum Displacement Angle
- 88 °
- Height
- 4.66-4.66 in
- Movement Of Operating Head
- rotary
- Base Plate Style
- style B
- Terminals Description Iso N°1
- A (left side contact) || B (right side contact)
- Short-Circuit Protection
- 20 A Bussmann class CC KTK-R-21 fuse non-time delay
- Tripping Angle
- 14 °
- Fixing Mode
- by the body
- Contacts Material
- silver flashed copper
- [Ithe] Conventional Enclosed Thermal Current
- 20 A
- Cable Entry
- 1 entry for 1/2" - 14 NPT ANSI B1.20.1
- Contact Form
- Form Z
- Electrical Connection
- screw-clamp terminals AWG 22...AWG 12
- Net Weight
- 2.5 lb(US)
- Switch Actuation
- CCW || from right
- Type Of Approach
- lateral approach
- [Ui] Rated Insulation Voltage
- 600 V 3)IEC 609470-1 || 600 V 3)UL 508 || 600 V 3)CSA C22.2 No 14
- Positive Opening
- without
- Contact Operation
- snap action
- Maximum Actuation Speed
- 130 ft/min with 30° cam angle, levers only || 90 ft/min with 45° cam angle, levers only
- Type Of Operator
- spring return without operating lever
- Body Material
- cast zinc
- Switch Function
- SPDT-DB
- [Uimp] Rated Impulse Withstand Voltage
- 2.5 kV AC for 1 minute CE || 2.2 kV AC for 1 minute UL || 2.64 kV AC for 1 minute CSA
- Contact Code Designation
- A600, AC (Ue = 600 V) Ie = 5 A NEMA rating designation || A600, AC (Ue = 480 V) Ie = 6.25 A NEMA rating designation || A600, AC (Ue = 240 V) Ie = 12.5 A NEMA rating designation || A600, AC (Ue = 120 V) Ie = 20 A NEMA rating designation || P600, DC (Ue = 600 V) Ie = 0.2 A NEMA rating designation || P600, DC (Ue = 250 V) Ie = 1 A NEMA rating designation || P600, DC (Ue = 120 V) Ie = 5 A NEMA rating designation
- Width
- 2.25 in
- Depth
- 2.44 in
- Minimum Torque For Tripping
- 12 lbf.in
- Number Of Poles
- 1
- Repeat Accuracy
- +/- 0.004 in linear travel of cam on 1.5 in lever arm
- Contact Sequence Number
- 5
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP111160EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Ambient Air Temperature For Operation
- -10-185 °F
- Shock Resistance
- 30 gn 9 ms IEC 60068-2-27
- Vibration Resistance
- 10 gn 10-55 Hz)IEC 60068-2-6
- Ip Degree Of Protection
- IP67 conforming to IEC 60529
- Ambient Air Temperature For Storage
- -10-185 °F
- Nema Degree Of Protection
- NEMA 1 Nema type 250 || NEMA 2 Nema type 250 || NEMA 4 Nema type 250 || NEMA 12 Nema type 250 || NEMA 13 Nema type 250
- Electrical Shock Protection Class
- class 0 IEC 61140
- Protective Treatment
- corrosion resistant gray paint
Dokumenty
Data Sheet
PobierzInne kategorie
SiłownikiBlokiKable, rury i wężeSprężarkiSterowanieŁączniki i osprzętCylindry i tłokiElektronikaFiltryHVACKomputery przemysłowe i interfejsy HMIOświetlenieTechnika liniowaSilnikiZasilaniePrzeniesienie napęduPompy i zaworyEnergia odnawialnaRobotykaUszczelki, pierścienie i złączaCzujniki i urządzenia pomiaroweNarzędzia i akcesoriaCNCInne