Schneider Electric
9012GAWM4
Pressure switch 9012G, adjustable scale, 2 thresholds, 1.5 to 75 PSIG
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Stan produktu:
Additional Information
- Part Number
- 9012GAWM4
- UPC
- 785901459507
- UNSPSC
- 39122210
- Tariff Code
- 9032200000
- Country of Origin
- MX
Specifications
- Pressure Sensor Type
- electromechanical pressure switch
- Range Of Product
- 9012G
- Maximum Pressure
- 240 psi
- Pressure Switch Type Of Operation
- regulation between 2 thresholds
- Contacts Type And Composition
- NC-NO, SPDT-DB, Form Z, snap action, silver nickel contacts
- Local Display
- without
- Pressure Sensor Name
- 9012G
- Fluid Connection Type
- 0.25 inch BS2779 parallel pipe thread UL 508
- Pressure Sensor Size
- 75 psi
- Controlled Fluid
- hydraulic oil -40-250 °F) || non-corrosive liquids || air || non-corrosive gas
- Scale Type
- adjustable differential
Contractual warranty
- Warranty
- 18 months
Complementary
- Repeat Accuracy
- 4 %
- Height
- 5.55 in
- Pressure Actuator
- diaphragm nitrile (Buna-N)
- Terminal Block Type
- 4 screw terminals
- Short-Circuit Protection
- 10 A cartridge overload and short-circuit protection gL
- Line Rated Current
- 3 A 240 V AC A600 NEMA rating designation || 6 A 120 V AC A600 NEMA rating designation || 0.27 A 250 V DC R300 NEMA rating designation || 0.22 A 125 V DC R300 NEMA rating designation
- Range On Decreasing Pressure
- 1.5-75 psi
- Electrical Connection
- screw-clamp terminals, AWG 22...AWG 12
- Materials In Contact With Fluid
- nitrile (Buna-N)
- Net Weight
- 3 lb(US)
- Local Signalling
- without
- Maximum Operating Rate
- 120 cyc/mn
- Setting
- internal
- Mechanical Durability
- 5000000 cycles
- Cable Entry
- 20 mm BS4568 conduit entrance
- Operating Position
- any position
- Electrical Circuit Type
- control circuit
- Enclosure Material
- die cast aluminium alloy 380
- Approx Adjustable Differential At Mid Range
- 3.5-15 psi +/- 2.5 % full scale
- Width
- 3.5 in
- Depth
- 2.63 in
Offer Sustainability
- Environmental Disclosure
- ENVPEP111211EN
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Circularity Profile
- ENVEOLI111210EN
- Eu Rohs Directive
- Not applicable, out of EU RoHS legal scope
Environment
- Product Certifications
- UL listed file E12158 CCN NKPZ and CCN NTHT || CSA LR25490 class 3211 03
- Ambient Air Temperature For Operation
- -10-185 °F
- Standards
- UL 508 || CE || CSA C22.2 No 14
- Shock Resistance
- 50 gn IEC 58-2-27
- Vibration Resistance
- 2 gn 40-150 Hz)IEC 68-2-6
- Nema Degree Of Protection
- NEMA 4/4X/13 UL 50
Dokumenty
Data Sheet
PobierzInne kategorie
SiłownikiBlokiKable, rury i wężeSprężarkiSterowanieŁączniki i osprzętCylindry i tłokiElektronikaFiltryHVACKomputery przemysłowe i interfejsy HMIOświetlenieTechnika liniowaSilnikiZasilaniePrzeniesienie napęduPompy i zaworyEnergia odnawialnaRobotykaUszczelki, pierścienie i złączaCzujniki i urządzenia pomiaroweNarzędzia i akcesoriaCNCInne