Schneider Electric
9038AR1
1 / 1
Opis
Końcówka Serii
This product is part of the NEMA Pressure Switches range, an offer of mechanical alternators. This mechanical alternator has 4 normally closed, snap action, DPST-DB (double pole single throw, double break) form YY contacts. The open tank mechanical alternator supports pedestal mounting method and vertical float rod angle for operating in any position. It is furnished with screw clamp terminals for electrical connection and 2 conduit entries for 3/4-14 NPT. Offers electrical durability of 100 cycles and mechanical durability of 300 cycles. The enclosure is made of cast aluminum. It is a NEMA 7/9 rated product. This product is certified by UL, CSA, CE. Meets UL 508 standards. When liquid level rises to the first level, one pump turns on. Both pumps automatically turn on when a peak condition occurs and the liquid level continues to rise. If form N5 or N25 is present and the water level continues to rise. Mechanical alternator provides a simple, positive means of mechanically alternating two pumps or motors. This alternator is used on devices that are installed in a duplex system with a common tank. It is a NEMA 7/9 rated product. This product is certified by CE, CSA and UL. Meets UL 508 standards. When liquid level rises to the first level, one pump turns on. Both pumps automatically turn on when a peak condition occurs and the liquid level continues to rise. If form N5 or N25 is present and the water level continues to rise. Mechanical alternator provides a simple, positive means of mechanically alternating two pumps or motors. This alternator is used on devices that are installed in a duplex system with a common tank.- Country of Origin
- MX
- Part Number
- 9038AR1
- Tariff Code
- 8536509065
- EAN
- 39122219
- UPC
- 785901591054
- UNSPSC
- 39122219
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Specifications
- Range Of Product
- Square D Pumptrol
- Product Or Component Type
- mechanical alternator
- Type Of Packing
- individual
- Product Specific Application
- mechanically alternating the operation of two pumps or motors
- Quantity Per Set
- set of 1
- Electrical Circuit Type
- power circuit
- Device Application
- open tank
- Device Short Name
- 9038A
Contractual warranty
- Warranty
- 18 months
Complementary
- Product Destination
- for open tank
- Terminal Block Type
- 8 terminals
- Terminals Description Iso N°1
- line-load-load-line
- Short-Circuit Protection
- 20 A cartridge fuse gG
- Device Mounting
- pedestal
- Float Rod Angle
- vertical
- Factory Modification
- without
- Float Movement
- variable adjustable
- Maximum Operating Rate
- 60 cyc/mn
- Contacts Type And Composition
- 4 NC, snap action, DPST-DB, Form YY
- Float Position
- any
- Electrical Durability
- 100 cycles 60 cyc/mn
- Cable Entry Number
- 2 conduit entries for 3/4"-14 NPT UL 508
- Electrical Connection
- screw-clamp terminals 10 AWG
- Contact Operation
- contacts close on liquid rise
- [Ui] Rated Insulation Voltage
- 575 V UL 508
- Controlled Fluid
- fresh water specific gravity of 0.85 in or higher || sea water specific gravity of 0.85 in or higher || hydraulic oil specific gravity of 0.85 in or higher || corrosive fluid specific gravity of 0.85 in or higher
- Mechanical Durability
- 300 cycles
- Operating Position
- vertical position only
- Enclosure Material
- Cast Aluminium
- Local Signalling
- without
- Motor Power Kw
- 1.5 kW 2 hp)115 V AC, 1 phase || 2.2 kW 3 hp)115 V AC, 3 phase || 2.2 kW 3 hp)230 V AC, 1 phase || 3.7 kW 5 hp)230 V AC, 3 phase || 0.75 kW 1 hp)460 V AC, 3 phase || 0.75 kW 1 hp)475 V AC, 3 phase || 0.18 kW 0.25 hp)32 V DC || 0.37 kW 0.5 hp)115 V DC || 0.37 kW 0.5 hp)230 V DC
- Kit Composition
- float switch || rod and float are to be choosen in accessories
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP111211EN
- Sustainable Offer Status
- Green Premium product
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Diisononyl phthalate (DINP), which is known to the State of California to cause cancer, and Di-isodecyl phthalate (DIDP), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Circularity Profile
- ENVEOLI111210EN
- Eu Rohs Directive
- Pro-active compliance (Product out of EU RoHS legal scope)
Environment
- Product Certifications
- CSA file LR26817 || UL listed file E12443
- Ambient Air Temperature For Operation
- -22-220 °F
- Standards
- CE || UL 508
- Ambient Air Temperature For Storage
- -22-220 °F
- Nema Degree Of Protection
- NEMA 7/9 UL 698
Dokumenty
Data Sheet
PobierzInne kategorie
SiłownikiBlokiKable, rury i wężeSprężarkiSterowanieŁączniki i osprzętCylindry i tłokiElektronikaFiltryHVACKomputery przemysłowe i interfejsy HMIOświetlenieTechnika liniowaSilnikiZasilaniePrzeniesienie napęduPompy i zaworyEnergia odnawialnaRobotykaUszczelki, pierścienie i złączaCzujniki i urządzenia pomiaroweNarzędzia i akcesoriaCNCInne