Schneider Electric
9080FB1611CC
1 / 1
Opis
Końcówka Serii
Linergy NEMA fuse holders are panel mount fuse holders that will accept class H, R, CC, M, and J fuses up to 200 Amps. This one pole fuse holder will accept class CC fuses. The rating of the fuse can be up to 30 Amps with a 600 V maximum rating. The pressure wire connectors will accept 14 to10 AWG (2.5 to 4 mm2) solid or stranded copper wire. Fuse clips are made of a copper alloy that is tin plated. The fuse clips are standard fuse clips. The fuse holder base is made of high impact thermoplastic. AIC Rating in accordance with UL512 is 200,000 Amp. This fuse holder is UL listed and CSA certified. Type S starters are UL listed and CSA certified for global applications.- Country of Origin
- US
- Part Number
- 9080FB1611CC
- Tariff Code
- 8536904000
- EAN
- 39121624
- UPC
- 785901097198
- UNSPSC
- 39121624
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Specifications
- Range Of Product
- 9080FB
- Product Or Component Type
- fuse holder
Complementary
- Product Certifications
- UL recognized E40747 CCN IZLT2 || CSA file 70360 class 6225 01 || CE
- Fuse Size
- 0.4063 x 1.5 in
- [Ics] Rated Service Breaking Capacity
- 200 kA UL 512
- Ambient Air Temperature For Operation
- -40-257 °F
- Height
- 3.13 in
- Mounting Support
- surface mount
- Connections - Terminals
- screw terminals 25 lbf.in AWG 14...AWG 10 copper
- Wire Stripping Length
- 0.4375 in
- Fuse Type
- CC
- Material
- thermoplastic: block
- Electrical Connection
- pressure wire clamp
- Line Rated Current
- 30 A
- Awg Gauge
- AWG 14...AWG 10 copper or aluminium
- Width
- 0.85 in
- Depth
- 1.29 in
- Number Of Poles
- 1
- [Ue] Rated Operational Voltage
- <= 600 V AC/DC
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Toxic Heavy Metal Free
- Yes
- Reach Regulation
- Free of Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- Reach Free Of Svhc
- Yes
- China Rohs Regulation
- Pro-active China RoHS declaration (out of China RoHS legal scope)
- Eu Rohs Directive
- Compliant
Contractual warranty
- Warranty
- 18 months
Dokumenty
Data Sheet
PobierzInne kategorie
SiłownikiBlokiKable, rury i wężeSprężarkiSterowanieŁączniki i osprzętCylindry i tłokiElektronikaFiltryHVACKomputery przemysłowe i interfejsy HMIOświetlenieTechnika liniowaSilnikiZasilaniePrzeniesienie napęduPompy i zaworyEnergia odnawialnaRobotykaUszczelki, pierścienie i złączaCzujniki i urządzenia pomiaroweNarzędzia i akcesoriaCNCInne