Schneider Electric
BGL26000S12
Automatic switch, PowerPacT B, 125A, 2 pole, 600VAC, 18kA, EverLink lug, magnetic
- Termin płatności do 90 dni od 500+ dostawców.
- Rabaty na odsprzedaż do 40%!
Wyślij zapytanie o cenę
1
Metody płatności:
Additional Information
- Part Number
- BGL26000S12
- UNSPSC
- 39121601
Complementary
- Mounting Mode
- clip-on 35 x 15 mm symmetrical DIN rail) || by screws plate)
- Height
- 137 mm
- Connection Pitch
- 27 mm
- Contact Position Indicator
- yes
- [Ue] Rated Operational Voltage
- 600Y/347 V AC 50/60 Hz UL 489
- Tightening Torque
- 5-5 N.m 2.5-10 mm² || 9-9 N.m 16-95 mm²
- Breaking Capacity Code
- G
- 9 Mm Pitches
- 6
- Magnetic Tripping Current
- 1320-1320 A
- Number Of Slots
- 1 auxiliary switch OF plug-in) || 1 voltage release MN or MX plug-in)
- Electrical Connection
- Everlink lug, line || Everlink lug, load
- Magnetic Hold Current
- 880 A
- Control Type
- toggle
- Wire Stripping Length
- 20 mm
- Mechanical Durability
- 15000 cycles IEC 947-1 Annex K ed 5.2
- Short-Circuit Withstand
- 65 kA 208Y/120 V UL 489 || 65 kA 240 V UL 489 || 35 kA 480Y/277 V UL 489 || 35 kA 480 V UL 489 || 18 kA 600 V UL 489
- Electrical Durability
- 10000 cycles IEC 947-1 Annex K ed 5.2 440 V In
- Local Signalling
- for presence of auxiliary contacts flag (green)
- Poles Description
- 2P
- Quantity Per Set
- set of 1
- Line Rated Current
- 125 A
- Awg Gauge
- AWG 6...AWG 2/0 fine stranded aluminium/copper || AWG 14...AWG 3/0 rigid or stranded aluminium/copper
- Color
- Gray RAL 7016)
- Width
- 36 mm
- Depth
- 89 mm
Offer Sustainability
- Rohs Exemption Information
- Yes
- Mercury Free
- Yes
- Environmental Disclosure
- ENVPEP1610005EN
- Sustainable Offer Status
- Green Premium product
- Pvc Free
- Yes
- Reach Regulation
- Reference contains Substances of Very High Concern above the threshold
- California Proposition 65
- WARNING: This product can expose you to chemicals including: DINP, which is known to the State of California to cause cancer, and DIDP, which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
- China Rohs Regulation
- Product out of China RoHS scope. Substance declaration for your information.
- Circularity Profile
- N/A
- Eu Rohs Directive
- Compliant with Exemptions
- Halogen Content Performance
- Halogen free product
Environment
- Ambient Air Temperature For Operation
- -25-70 °C
- Standards
- UL 489
- Product Certifications
- UL
- Ambient Air Temperature For Storage
- -50-85 °C
- Quality Labels
- CE
- Operating Altitude
- 6561.68 ft (2000 m) without derating || 5000 m with derating
Specifications
- Product Or Component Type
- automatic switch
- Product Name
- PowerPact B
- Range
- PowerPact
- Device Application
- distribution
Dokumenty
Data Sheet
PobierzInne kategorie
SiłownikiBlokiKable, rury i wężeSprężarkiSterowanieŁączniki i osprzętCylindry i tłokiElektronikaFiltryHVACKomputery przemysłowe i interfejsy HMIOświetlenieTechnika liniowaSilnikiZasilaniePrzeniesienie napęduPompy i zaworyEnergia odnawialnaRobotykaUszczelki, pierścienie i złączaCzujniki i urządzenia pomiaroweNarzędzia i akcesoriaCNCInne