Opis

Końcówka Serii
The Homeline load center offer features Homeline circuit breakers, ground fault circuit breakers and arc fault interrupters. Homeline load centers enable the use of a full complement of accessories. Systems are single phase and are rated for indoor use or are rain proof. Homeline load centers are designed for residential and industrial use to protect electrical systems, equipment and people. This Homeline load center is supplied with fixed main lugs that are rated at 100A 120/240 VAC single phase. Homeline load center provides a 10 kA breaking capacity. This system provides 6 spaces in a NEMA 1 indoor enclosure. Has a flush cover. The electrical connections are box lugs. The box lugs will accept a wire range of 8 AWG to 1 AWG copper or aluminum wire. This Homeline load center has a height of 12.55 inches, a width of 8.89 inches, and depth of 3.81 inches. Homeline load centers are UL Listed.
Part Number
HOM612L100F
Tariff Code
8537109150
UPC
785901061182
UNSPSC
39121101
  • Termin płatności do 90 dni od 500+ dostawców.
  • Rabaty na odsprzedaż do 40%!
Zarejestruj się
Wyślij zapytanie o cenę
1
Metody płatności:
Poproś o wycenę, a prześlemy Ci informacje o dostępności i cenie.

Environment

Product Certifications
UL listed file E-6294
Ambient Air Temperature For Operation
-5 °C || 40 °C

Contractual warranty

Warranty
Lifetime

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP1403002
Sustainable Offer Status
Green Premium product
Toxic Heavy Metal Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Lead and lead compounds, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
Pro-active China RoHS declaration (out of China RoHS legal scope)
Circularity Profile
N/A
Eu Rohs Directive
Compliant

Complementary

Height
319 mm
Bus Rated Current
100.0 A
Phase
1 phase
Short-Circuit Current
10 kA
Number Of Tandem Circuit Breakers
6
Material
tin plated aluminium: busbar
Surface Finish
baked enamel Gray
Enclosure Material
welded sheet steel
Awg Gauge
AWG 8...AWG 1 aluminium/copper
Width
226 mm
Wiring Configuration
3-wire
Depth
97 mm
Box Number
4

Specifications

Range Of Product
Homeline
Product Or Component Type
Load Center
Number Of Circuits
12
Number Of Spaces
6
Nema Degree Of Protection
NEMA 1 indoor
Cover Type
flush cover
Line Rated Current
100 A
Load Center Type
Fixed Mains (lugs)

Dokumenty

Data Sheet

Pobierz