1 / 1
thumbnail

Opis

TeSys F contactor, 3 poles (3NO), 150A/690V AC-3, for motor applications up to 75kW@400V. It provides a low sealed consumption 440V 40-400Hz AC coil, bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Country of Origin
CZ
Part Number
LC1F150R7
Tariff Code
85364900
EAN
3389118093829
UNSPSC
39121529
Metody płatności:
Najlepsza oferta od:
SKZaufany dostawca Automa.Net
Dostępność:
10 szt.
W magazynie
Zaktualizowano: 08-11-2024
Gwarancja:
12 miesięcy
Szacowany czas dostawy:
Na zapytanie
Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Fabrycznie Nowe, Zapieczętowane - Nowy, nieużywany, nieotwarty, nieuszkodzony przedmiot w oryginalnym opakowaniu zapieczętowanym przez producenta.
Łącznie 11 części w magazynie od 2 dostawców
Dostawa z:
SK
SK
DE
DE
Bezpieczny proces płatności
Zasady zwrotu i refundacji
Zasady wysyłki
Gwarancja

Dostępne Oferty (1)

LC1F150R7 product image
Schneider Electric

LC1F150R7

Stan produktu:
Nowy, Rynek wtórny
Dostępność:
1 szt.
W magazynie
Zaktualizowano: 08-11-2024
Oferta od:
DEZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
Gwarancja:
12 miesięcy
1
Oferta z czasem realizacji przez producenta
Wysyłka:Na zapytanie
Najlepsza cena:
€746.43

Specifications

[Uc] Control Circuit Voltage
440 V AC 40...400 Hz
Range Of Product
TeSys F
[Ue] Rated Operational Voltage
<= 690 V AC 50/60 Hz || <= 460 V DC
Contactor Application
motor control || resistive load
Product Or Component Type
contactor
Range
TeSys
Utilisation Category
AC-3 || AC-1 || AC-4
[Ie] Rated Operational Current
250 A 40 °C) <= 440 V AC-1 || 150 A 55 °C) <= 440 V AC-3
Poles Description
3P
Device Short Name
LC1F

Contractual warranty

Warranty
18 months

Complementary

Product Certifications
UL || CB || BV || DNV || CCC || RINA || RMRoS || ABS || LROS (Lloyds register of shipping) || UKCA
Power Dissipation Per Pole
22 W AC-1 || 8 W AC-3
Average Impedance
0.35 mOhm - Ith 250 A 50 Hz
[Ith] Conventional Free Air Thermal Current
250 A 40 °C
Control Circuit Voltage Limits
operational 0.85...1.1 Uc 40...400 Hz 55 °C) || drop-out 0.2...0.55 Uc 40...400 Hz 55 °C)
Standards
EN 60947-4-1 || IEC 60947-1 || JIS C8201-4-1 || EN 60947-1 || IEC 60947-4-1
Mounting Support
plate
Control Circuit Type
AC 40...400 Hz
Rated Breaking Capacity
1200 A IEC 60947-4-1
Associated Fuse Rating
160 A aM <= 440 V || 250 A gG <= 440 V
[Uimp] Rated Impulse Withstand Voltage
8 kV
Inrush Power In Va
770-770 VA, 40...400 Hz 0.9 20 °C)
Connections - Terminals
control circuit screw clamp terminals 1 1-4 mm²flexible without cable end || control circuit screw clamp terminals 2 1-4 mm²flexible without cable end || control circuit screw clamp terminals 1 1-4 mm²flexible with cable end || control circuit screw clamp terminals 2 1-2.5 mm²flexible with cable end || control circuit screw clamp terminals 1 1-4 mm²solid without cable end || control circuit screw clamp terminals 2 1-4 mm²solid without cable end || power circuit bar 2 25 x 3 mm || power circuit lugs-ring terminals 1 120-120 mm² || power circuit connector 1 120-120 mm² || power circuit bolted connection
Pole Contact Composition
3 NO
Operating Time
35 ms closing at Uc) || 130 ms opening at Uc)
Maximum Operating Rate
2400 cyc/h 55 °C
Mechanical Durability
10 Mcycles
Tightening Torque
control circuit 1.2 N.m || power circuit 18 N.m
Compatibility Code
LC1F
Hold-In Power Consumption In Va
8.1-8.1 VA, 40...400 Hz 0.9 20 °C)
Overvoltage Category
III
Motor Power Kw
75 kW 380...400 V AC 50/60 Hz AC-3) || 80 kW 415 V AC 50/60 Hz AC-3) || 80 kW 440 V AC 50/60 Hz AC-3) || 90 kW 500 V AC 50/60 Hz AC-3) || 100 kW 660...690 V AC 50/60 Hz AC-3) || 40 kW 220...230 V AC 50/60 Hz AC-3) || 22 kW 400 V AC 50/60 Hz AC-4)
[Ui] Rated Insulation Voltage
1000 V IEC 60947-4-1 || 1500 V VDE 0110 group C
[Icw] Rated Short-Time Withstand Current
1200 A 40 °C - 10 s || 700 A 40 °C - 30 s || 600 A 40 °C - 1 min || 450 A 40 °C - 3 min || 350 A 40 °C - 10 min
Heat Dissipation
5.9-7.2 W

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP111201EN
Sustainable Offer Status
Green Premium product
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
Weee
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
China Rohs Regulation
Product out of China RoHS scope. Substance declaration for your information.
Circularity Profile
ENVEOLI111214EN_V1
Eu Rohs Directive
Compliant

Environment

Ambient Air Temperature For Operation
-40-60 °C
Height
170 mm
Net Weight
3.43 kg
Ambient Air Temperature For Storage
-60-80 °C
Protective Treatment
TH
Ip Degree Of Protection
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Operating Altitude
9842.52 ft (3000 m) without derating
Width
163.5 mm
Depth
171 mm
Permissible Ambient Air Temperature Around The Device
60-70 °C at Uc

Modele CAD

traceparts
traceparts
Pobierz