Opis

Końcówka Serii
TeSys Giga high power contactor, 3 poles (3 NO) for category AC-3 applications up to 265A 160kW@440V. It provides a 200-500V AC/DC wide band low consumption electronic coil, PLC output control and embedded highly reliability 1NO+1NC auxiliary contact block (17V 1mA). Designed for demanding applications with maximum operating rates up to 600 cycles per hour and environments until 60°C. It procures high reliability and durability with 5 Mcycles mechanical durability. Local and Remote Contact Wear Diagnosis (CWD) as standard function, continuous monitoring with healthy and alarm indicators. It is possibility to replace switching module (main contacts), enhancement contactor life. Contactor can be fixed in all quadrants, maintenance without removing cables/busbars, and OLR could be directly mounted below contactor. To be used with power connection by bolted connection with cable memory kit and control connections by spring terminals, accessible from front for easy and quick replacement. It provides IP2x protection in Front face with shrouds conforming to IEC 60529 and VDE 0106. It can cover -25°C to 60°C operation ambient air temperature and directly mounted on plate, No derating up to 3000m altitude. The dimension is 290mm x 140mm x 209mm (H x W x D), compact size enables panel space savings. Multi standards certified(CE,CB,CCC,cULus,EAC,KC,RCM,Marine) and Green Premium compliant (RoHs/Reach). Unique QR code provides quick access to complete product data.
Country of Origin
CN
Part Number
LC1G265LSEA
Tariff Code
85364900
EAN
3606481922465
UNSPSC
39121529
Metody płatności:
Najlepsza oferta od:
CZZaufany dostawca Automa.Net
Dostępność:
3 szt.
W magazynie
Zaktualizowano: 07-11-2024
Szacowany czas dostawy:
Na zapytanie
Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Fabrycznie Nowe, Zapieczętowane - Nowy, nieużywany, nieotwarty, nieuszkodzony przedmiot w oryginalnym opakowaniu zapieczętowanym przez producenta.
Łącznie 54 części w magazynie od 16 dostawców
Bezpieczny proces płatności
Zasady zwrotu i refundacji
Zasady wysyłki
Gwarancja

Dostępne Oferty (15)

Najlepsza oferta
LC1G265LSEA product image
Schneider Electric

LC1G265LSEA

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
3 szt.
W magazynie
Zaktualizowano: 07-11-2024
Oferta od:
GBZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
£1,216.14
net
LC1G265LSEA product image
Schneider Electric

LC1G265LSEA

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
3 szt.
W magazynie
Zaktualizowano: 07-11-2024
Oferta od:
NLZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
€1,331.61
net
LC1G265LSEA product image
Schneider Electric

LC1G265LSEA

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
3 szt.
W magazynie
Zaktualizowano: 07-11-2024
Oferta od:
ITZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
€1,472.00
net
LC1G265LSEA product image
Schneider Electric

LC1G265LSEA

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
3 szt.
W magazynie
Zaktualizowano: 07-11-2024
Oferta od:
DEZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
€1,686.00
net
LC1G265LSEA product image
Schneider Electric

LC1G265LSEA

Stan produktu:
Fabrycznie Nowe, Zapieczętowane
Dostępność:
3 szt.
W magazynie
Zaktualizowano: 07-11-2024
Oferta od:
ESZaufany dostawca Automa.Net
Szacowany czas dostawy:
Na zapytanie
1
€1,948.15
net
Oferta z czasem realizacji przez producenta
Wysyłka:Na zapytanie
Najlepsza cena:
€456.55

Specifications

[Uc] Control Circuit Voltage
200...500 V AC 50/60 Hz || 200...500 V DC
[Ue] Rated Operational Voltage
<= 1000 V AC 50/60 Hz || <= 460 V DC
Range Of Product
TeSys Giga
Control Circuit Voltage Limits
operational: 0.8 Uc Min...1.1 Uc Max (at <60 °C) || drop-out: 0.1 Uc Max...0.45 Uc Min (at <60 °C)
Contactor Application
power switching || motor control
Product Or Component Type
contactor
Range
TeSys
Utilisation Category
AC-1 || AC-3 || AC-3e || AC-4 || AC-5a || AC-5b || AC-6a || AC-6b || AC-8b || AC-8a || DC-1 || DC-3 || DC-5
[Ie] Rated Operational Current
385 A (at <40 °C) at <= 1000 V AC-1 || 265 A (at <60 °C) at <= 440 V AC-3
Poles Description
3P
Device Short Name
LC1G

Offer Sustainability

Rohs Exemption Information
Yes
Mercury Free
Yes
Environmental Disclosure
ENVPEP2105013
Sustainable Offer Status
Green Premium product
Pvc Free
Yes
Reach Regulation
Reference contains Substances of Very High Concern above the threshold
California Proposition 65
WARNING: This product can expose you to chemicals including: Styrene, which is known to the State of California to cause cancer, and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
China Rohs Regulation
X
Circularity Profile
ENVEOLI2105013
Eu Rohs Directive
Compliant with Exemptions
Halogen Content Performance
Halogen free plastic parts product

Complementary

Product Certifications
CB Scheme || CCC || cULus || EAC || CE || UKCA || EU-RO-MR by DNV-GL
Height
290 mm
Power Dissipation Per Pole
20 W AC-1 - Ith 385 A || 11 W AC-3 - Ith 265 A
Average Impedance
0.000144 Ohm
Auxiliary Contact Composition
1 NO + 1 NC
Connection Pitch
45 mm
Standards
EN/IEC 60947-4-1 || EN/IEC 60947-5-1 || UL 60947-4-1 || CSA C22.2 No 60947-4-1 || JIS C8201-4-1 || JIS C8201-5-1
Mounting Support
plate
Hold-In Power Consumption In W
9.0-9.0 W
Rated Breaking Capacity
2380 A at 440 V
Associated Fuse Rating
315 A aM at <= 440 V for motor || 250 A aM at <= 690 V for motor || 400 A gG at <= 690 V
Net Weight
8.2 kg
[Uimp] Rated Impulse Withstand Voltage
8 kV
Inrush Power In Va
530-530 VA
Pole Contact Composition
3 NO
Connections - Terminals
power circuit: bar 2 - busbar cross section: 32 x 10 mm || power circuit: lugs-ring terminals 1 185-185 mm² || power circuit: bolted connection || control circuit: push-in 1 0.2-2.5 mm² - cable stiffness: solid stranded without cable end || control circuit: push-in 1 0.25-2.5 mm² - cable stiffness: flexible with cable end || control circuit: push-in 2 0.5-1.0 mm² with cable end || control circuit: push-in 0.75-2.5 mm² - cable stiffness: solid stranded without cable end || control circuit: push-in 0.75-2.5 mm² - cable stiffness: flexible with cable end
Coil Technology
built-in bidirectional peak limiting
Operating Time
40...70 ms closing || 15...50 ms opening
Maximum Operating Rate
600 cyc/h AC-3 || 600 cyc/h AC-3e || 300 cyc/h AC-1 || 150 cyc/h AC-4
Mechanical Durability
8 Mcycles
Tightening Torque
35 N.m
Compatibility Code
LC1G
Hold-In Power Consumption In Va
16.1-16.1 VA
Width
140 mm
Overvoltage Category
III
Depth
226 mm
Maximum Horse Power Rating
75 hp at 200/208 V 60 Hz || 100 hp at 230/240 V 60 Hz || 200 hp at 460/480 V 60 Hz || 200 hp at 575/600 V 60 Hz
Motor Power Kw
75 kW at 230 V AC 50/60 Hz (AC-3e) || 132 kW at 400 V AC 50/60 Hz (AC-3e) || 132 kW at 415 V AC 50/60 Hz (AC-3e) || 160 kW at 440 V AC 50/60 Hz (AC-3e) || 160 kW at 500 V AC 50/60 Hz (AC-3e) || 200 kW at 690 V AC 50/60 Hz (AC-3e) || 160 kW at 1000 V AC 50/60 Hz (AC-3e) || 75 kW at 230 V AC 50/60 Hz (AC-3) || 132 kW at 400 V AC 50/60 Hz (AC-3) || 132 kW at 415 V AC 50/60 Hz (AC-3) || 160 kW at 440 V AC 50/60 Hz (AC-3) || 160 kW at 500 V AC 50/60 Hz (AC-3) || 200 kW at 690 V AC 50/60 Hz (AC-3) || 160 kW at 1000 V AC 50/60 Hz (AC-3) || 75 kW at 230 V AC 50/60 Hz (AC-4) || 132 kW at 400 V AC 50/60 Hz (AC-4) || 132 kW at 415 V AC 50/60 Hz (AC-4) || 150 kW at 440 V AC 50/60 Hz (AC-4) || 160 kW at 500 V AC 50/60 Hz (AC-4) || 160 kW at 690 V AC 50/60 Hz (AC-4) || 160 kW at 1000 V AC 50/60 Hz (AC-4)
[Ui] Rated Insulation Voltage
1000 V
Inrush Power In W
300 W
[Icw] Rated Short-Time Withstand Current
2.2 kA - 10 s || 1.23 kA - 30 s || 0.95 kA - 1 min || 0.62 kA - 3 min || 0.48 kA - 10 min

Environment

Ambient Air Temperature For Operation
-25-60 °C
Ambient Air Temperature For Storage
-60-80 °C
Protective Treatment
TH
Ip Degree Of Protection
IP2X front face with shrouds IEC 60529 || IP2X front face with shrouds VDE 0106
Mechanical Robustness
vibrations 5-300 Hz 2 gn contactor open || vibrations 5-300 Hz 4 gn contactor closed || shocks 10 gn 11 ms contactor open || shocks 15 gn 11 ms contactor closed
Color
dark grey
Permissible Ambient Air Temperature Around The Device
-40-70 °C at Uc

Modele CAD

traceparts
traceparts